Quality control of angular tube current modulation

被引:1
|
作者
Redzic, M. [1 ]
Beganovic, A. [2 ]
Civa, L. [3 ]
Jasic, R. [2 ]
Skopljak-Beganovic, A. [2 ]
Vegar-Zubovic, S. [4 ]
机构
[1] Inst Qual Control, Mostar, Bosnia & Herceg
[2] Sarajevo Univ, Dept Radiat Protect & Med Phys, Clin Ctr, Sarajevo, Bosnia & Herceg
[3] Sarajevo Sch Sci & Technol, Med Sch, Sarajevo, Bosnia & Herceg
[4] Sarajevo Univ, Clin Radiol, Clin Ctr, Sarajevo, Bosnia & Herceg
关键词
quality control; tube current modulation; computed tomography; dosimetry; radiation; CT; SYSTEM;
D O I
10.1007/978-981-10-4166-2_85
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Automatic exposure control (AEC) techniques in computed tomography (CT) have been defined as automatic modulation of tube current in the x-y plane (angular AEC), along the z-axis (z-axis AEC) or both (combined AEC), according to the size and attenuation characteristics of the body region being scanned. These techniques should provide constant image quality while lowering the radiation dose to patients. Although AEC is an important feature of all modern CT units, standard methodology for quality control of AEC does not exist. Aim of the paper was to provide reliable quality control (QC) method for AEC techniques used in CT. Change of tube current during the CT examination happens only if the scan projection radiogram (SPR) shows different size and attenuation characteristics of the object being scanned. In order to maintain repeatability of the modulation we used standard polymethyl methacrylate (PMMA) dosimetry phantom, placed with flat side along the z-axis. After SPR was taken, phantom was removed, and CT solid-state detector was placed in the isocenter. Measurements were performed in axial mode, one slice only, for different positions along the z-axis. Dose rates measured in the isocenter, that are proportional to tube current, were found depending on the phantom geometry. In the phantom center the width of rectangle is the same as the diameter of the cylindrical phantom (32 cm), while height corresponds to the cylinder thickness (15 cm). Results show that during the rotation the current is highest when the tube is positioned at the x-axis, and lowest when tube is crossing the y-axis. However, when the detector is moved to position z = 14.1 cm, tube current (air kerma rate) does not change during the rotation. The methodology presented in this study could be used as a basis for defining the QC procedure for TCM. The results are consistent with the expected outcomes.
引用
收藏
页码:563 / 567
页数:5
相关论文
共 50 条
  • [31] Tube current reduction in pediatric non-ECG-gated heart CT by combined tube current modulation
    Hyum Woo Goo
    Dong Soo Suh
    Pediatric Radiology, 2006, 36 : 344 - 351
  • [32] Tube current reduction in pediatric non-ECG-gated heart CT by combined tube current modulation
    Goo, HW
    Suh, DS
    PEDIATRIC RADIOLOGY, 2006, 36 (04) : 344 - 351
  • [33] Tube current reduction in pediatric non-ECG-gated heart CT by combined tube current modulation
    Hyun Woo Goo
    Dong Soo Suh
    Pediatric Radiology, 2006, 36 : 730 - 730
  • [34] Angular on-line tube current modulation in multidetector CT examinations of children and adults: The influence of different scanning parameters on dose reduction
    Papadakis, Antonios E.
    Perisinakis, Kostas
    Damilakis, John
    MEDICAL PHYSICS, 2007, 34 (07) : 2864 - 2874
  • [35] Automatic tube potential selection with tube current modulation in coronary CT angiography: Can it achieve consistent image quality among various individuals?
    Wang, Xiao-Ping
    Zhu, Xiao-Mei
    Zhu, Yin-Su
    Liu, Wang-Yan
    Yang, Xiao-Han
    Huang, Wei-Wei
    Xu, Yi
    Tang, Li-Jun
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2018, 16 (01) : 253 - 259
  • [36] Effect of Automatic Tube Current Modulation on Radiation Dose and Image Quality for Low Tube Voltage Multidetector Row CT Angiography: Phantom Study
    Schindera, Sebastian T.
    Nelson, Rendon C.
    Yoshizumi, Terry
    Toncheva, Greta
    Nguyen, Giao
    DeLong, David M.
    Szucs-Farkas, Zsolt
    ACADEMIC RADIOLOGY, 2009, 16 (08) : 997 - 1002
  • [37] Image quality and clinical usefulness of automatic tube current modulation technology in female chest computed tomography screening
    Li, Cheng
    Qi, Lin
    Zhang, Yusheng
    Gao, Feng
    Jin, Xiu
    Zhang, Lukai
    Tang, Huan
    Li, Ming
    MEDICINE, 2020, 99 (33) : E21719
  • [38] Image Quality Assessment of Deep Learning Image Reconstruction in Torso Computed Tomography Using Tube Current Modulation
    Takeuchi, Kazuhiro
    Ide, Yasuhiro
    Mori, Yuichiro
    Uehara, Yusuke
    Sukeishi, Hiroshi
    Goto, Sachiko
    ACTA MEDICA OKAYAMA, 2023, 77 (01) : 45 - 55
  • [39] Assessment of the Patient-Specific Image Quality for Chest Computed Tomography with Automatic Tube-Current Modulation
    Huang, Y.
    Liu, H.
    MEDICAL PHYSICS, 2020, 47 (06) : E515 - E515
  • [40] The influences of tube voltage and scan direction on combined tube current modulation: a phantom study
    Goo, Hyun Woo
    Suh, Dong Soo
    PEDIATRIC RADIOLOGY, 2006, 36 (08) : 833 - 840