Quality control of angular tube current modulation

被引:1
|
作者
Redzic, M. [1 ]
Beganovic, A. [2 ]
Civa, L. [3 ]
Jasic, R. [2 ]
Skopljak-Beganovic, A. [2 ]
Vegar-Zubovic, S. [4 ]
机构
[1] Inst Qual Control, Mostar, Bosnia & Herceg
[2] Sarajevo Univ, Dept Radiat Protect & Med Phys, Clin Ctr, Sarajevo, Bosnia & Herceg
[3] Sarajevo Sch Sci & Technol, Med Sch, Sarajevo, Bosnia & Herceg
[4] Sarajevo Univ, Clin Radiol, Clin Ctr, Sarajevo, Bosnia & Herceg
关键词
quality control; tube current modulation; computed tomography; dosimetry; radiation; CT; SYSTEM;
D O I
10.1007/978-981-10-4166-2_85
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Automatic exposure control (AEC) techniques in computed tomography (CT) have been defined as automatic modulation of tube current in the x-y plane (angular AEC), along the z-axis (z-axis AEC) or both (combined AEC), according to the size and attenuation characteristics of the body region being scanned. These techniques should provide constant image quality while lowering the radiation dose to patients. Although AEC is an important feature of all modern CT units, standard methodology for quality control of AEC does not exist. Aim of the paper was to provide reliable quality control (QC) method for AEC techniques used in CT. Change of tube current during the CT examination happens only if the scan projection radiogram (SPR) shows different size and attenuation characteristics of the object being scanned. In order to maintain repeatability of the modulation we used standard polymethyl methacrylate (PMMA) dosimetry phantom, placed with flat side along the z-axis. After SPR was taken, phantom was removed, and CT solid-state detector was placed in the isocenter. Measurements were performed in axial mode, one slice only, for different positions along the z-axis. Dose rates measured in the isocenter, that are proportional to tube current, were found depending on the phantom geometry. In the phantom center the width of rectangle is the same as the diameter of the cylindrical phantom (32 cm), while height corresponds to the cylinder thickness (15 cm). Results show that during the rotation the current is highest when the tube is positioned at the x-axis, and lowest when tube is crossing the y-axis. However, when the detector is moved to position z = 14.1 cm, tube current (air kerma rate) does not change during the rotation. The methodology presented in this study could be used as a basis for defining the QC procedure for TCM. The results are consistent with the expected outcomes.
引用
收藏
页码:563 / 567
页数:5
相关论文
共 50 条
  • [21] Uniform image quality achieved by tube current modulation using SD of attenuation in coronary CT angiography
    Hur, Gham
    Hong, Seong Wan
    Kim, Su Young
    Kim, Yong Hoon
    Hwang, Yoon Joon
    Lee, Won Ro
    Cha, Soon Joo
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (01) : 188 - 196
  • [22] The effects of tube current modulation on the noise power spectra of patients with different size; consequences for quality monitoring
    Fulco, Alexandro
    Cockmartin, Lesley
    Bosmans, Hilde
    Coolen, Johan
    Zhang, Guozhi
    Marshall, Nicholas
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [23] Effective dose and image quality evaluations of an automatic CT tube current modulation system with an anthropomorphic phantom
    Rampado, O.
    Marchisio, F.
    Izzo, A.
    Garelli, E.
    Bianchi, C. C.
    Gandini, G.
    Ropolo, R.
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 72 (01) : 181 - 187
  • [24] Improving linac integrated cone beam computed tomography image quality using tube current modulation
    Stankovic, Uros
    Ploeger, Lennert S.
    Sonke, Jan-Jakob
    MEDICAL PHYSICS, 2021, 48 (04) : 1739 - 1749
  • [25] Retrospective Tube Current Modulation Optimization of Individualized Organ-Level CT Dose and Image Quality
    Wang, Sen
    Medrano, Maria
    Imran, Abdullah-Al-Zubaer
    Stevens, Grant
    Tse, Justin Ruey
    Wang, Adam S.
    MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1, 2024, 12925
  • [26] Techniques and applications of automatic tube current modulation for CT
    Kalra, MK
    Maher, MM
    Toth, TL
    Schmidt, B
    Westerman, BL
    Morgan, HT
    Saini, S
    RADIOLOGY, 2004, 233 (03) : 649 - 657
  • [27] A framework to simulate CT images with tube current modulation
    Jadick, Giavanna
    Abadi, Ehsan
    Harrawood, Brian
    Sharma, Shobhit
    Segars, W. Paul
    Samei, Ehsan
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [28] Accurate Prediction of CT Tube Current Modulation: Estimating Tube Current Modulation Schemes for Voxelized Patient Models Used in Monte Carlo Simulations
    McMillan, K.
    Bostani, M.
    McCollough, C.
    McNitt-Gray, M.
    MEDICAL PHYSICS, 2015, 42 (06) : 3620 - 3620
  • [29] Software control for PWMA (angular pulse width modulation)
    Aghion, Cristian
    Ursaru, Ovidiu
    Lucanu, Mihai
    Dimitriu, Laurentiu
    Vornicu, Liliana
    ISSCS 2007: INTERNATIONAL SYMPOSIUM ON SIGNALS, CIRCUITS AND SYSTEMS, VOLS 1 AND 2, 2007, : 429 - +
  • [30] Multi-material decomposition in spectral CT with angular tube voltage modulation
    Su, Ting
    Zhu, Jiongtao
    Yang, Jiecheng
    Liang, Dong
    Ge, Yongshuai
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031