Atrial fibrosis identification with unipolar electrogram eigenvalue distribution analysis in multi-electrode arrays

被引:3
|
作者
Riccio, Jennifer [1 ]
Alcaine, Alejandro [2 ,3 ]
Rocher, Sara [4 ]
Martinez-Mateu, Laura [5 ]
Saiz, Javier [4 ]
Invers-Rubio, Eric [6 ]
Guillem, Maria S. [7 ]
Pablo Martinez, Juan [1 ,8 ]
Laguna, Pablo [1 ,8 ]
机构
[1] Univ Zaragoza, Aragon Inst Engn Res I3A, BSICoS Grp, Zaragoza, Spain
[2] Univ San Jorge, Fac Ciencias Salud, CoMBA Grp, Zaragoza, Spain
[3] Univ San Jorge, Fac Ciencias Salud, BSICoS Grp, Zaragoza, Spain
[4] Univ Politecn Valencia, Ctr Invest & Innovac Ingn, Valencia, Spain
[5] Univ Rey Juan Carlos, Dept Teoria Senal & Comunicac Sistemas Telemat &, Madrid, Spain
[6] Hosp Clin Barcelona, IDIBAPS Inst, Barcelona, Spain
[7] Univ Politecn Valencia, ITACA Inst, Valencia, Spain
[8] Ctr Invest Biomed Red Bioingn Biomat & Nanomed CI, Zaragoza, Spain
关键词
Atrial fibrosis; Atrial fibrillation (AF); Bipolar electrograms (b-EGMs); Eigenvalue dominance ratio (EIGDR); Unipolar electrograms (u-EGMs); IONIC MECHANISMS; FIBRILLATION; COMPONENT; ABLATION; MYOCYTES; CURRENTS;
D O I
10.1007/s11517-022-02648-3
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Atrial fibrosis plays a key role in the initiation and progression of atrial fibrillation (AF). Atrial fibrosis is typically identified by a peak-to-peak amplitude of bipolar electrograms (b-EGMs) lower than 0.5 mV, which may be considered as ablation targets. Nevertheless, this approach disregards signal spatiotemporal information and b-EGM sensitivity to catheter orientation. To overcome these limitations, we propose the dominant-to-remaining eigenvalue dominance ratio (EIGDR) of unipolar electrograms (u-EGMs) within neighbor electrode cliques as a waveform dispersion measure, hypothesizing that it is correlated with the presence of fibrosis. A simulated 2D tissue with a fibrosis patch was used for validation. We computed EIGDR maps from both original and time-aligned u-EGMs, denoted as R and R-A, respectively, also mapping the gain in eigenvalue concentration obtained by the alignment, Delta R-A. The performance of each map in detecting fibrosis was evaluated in scenarios including noise and variable electrode-tissue distance. Best results were achieved by R-A, reaching 94% detection accuracy, versus the 86% of b-EGMs voltage maps. The proposed strategy was also tested in real u-EGMs from fibrotic and non- fibrotic areas over 3D electroanatomical maps, supporting the ability of the EIGDRs as fibrosis markers, encouraging further studies to confirm their translation to clinical settings.
引用
收藏
页码:3091 / 3112
页数:22
相关论文
共 50 条
  • [31] Study of hypothermia on cultured neuronal networks using multi-electrode arrays
    Rubinsky, Liel
    Raichman, Nadav
    Baruchi, Itay
    Shein, Mark
    Lavee, Jacob
    Frenk, Harlan
    Ben-Jacob, Eshel
    JOURNAL OF NEUROSCIENCE METHODS, 2007, 160 (02) : 288 - 293
  • [32] HTsort: Enabling Fast and Accurate Spike Sorting on Multi-Electrode Arrays
    Chen, Keming
    Jiang, Yangtao
    Wu, Zhanxiong
    Zheng, Nenggan
    Wang, Haochuan
    Hong, Hui
    FRONTIERS IN COMPUTATIONAL NEUROSCIENCE, 2021, 15
  • [33] Bipolar voltage analysis with multi-electrode mapping
    Chaturvedi, Vivek
    Maille, Baptiste
    Gupta, Dhiraj
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2017, 28 (11) : E3 - E3
  • [34] Response profiles of murine spiral ganglion neurons on multi-electrode arrays
    Hahnewald, Stefan
    Tscherter, Anne
    Marconi, Emanuele
    Streit, Juerg
    Widmer, Hans Rudolf
    Garnham, Carolyn
    Benav, Heval
    Mueller, Marcus
    Loewenheim, Hubert
    Roccio, Marta
    Senn, Pascal
    JOURNAL OF NEURAL ENGINEERING, 2016, 13 (01)
  • [35] Multi-site two-photon imaging of neurons on multi-electrode arrays
    Potter, SM
    Lukina, N
    Longmuir, KJ
    Wu, Y
    MULTIPHOTON MICROSCOPY IN THE BIOMEDICAL SCIENCES, 2001, 4262 : 104 - 110
  • [36] The rapid mapping for atrial tachycardia using multi-electrode basket catheter
    Okubo, K.
    Kuwahara, T.
    Nakashima, E.
    Yamao, K.
    Watari, Y.
    Nakajima, J.
    Takigawa, M.
    Fujino, T.
    Takagi, K.
    Takahashi, A.
    EUROPEAN HEART JOURNAL, 2014, 35 : 20 - 21
  • [37] Optimization of the multi-electrode electrostatic sensor for velocity distribution measurement
    Wang, Chao
    Zhang, Wenbiao
    Wu, Weiping
    8TH INTERNATIONAL SYMPOSIUM ON MEASUREMENT TECHNIQUES FOR MULTIPHASE FLOWS, 2014, 1592 : 43 - 49
  • [38] Intelligent Multi-Electrode Arrays as the Next Generation of Electrochemical Biosensors for Real-Time Analysis of Neurotransmitters
    Mazafi, Alon
    Shukla, Rajendra P.
    Shukla, Sudheesh K.
    Lavon, Avia
    Ben-Yoav, Hadar
    Silue, Adissa
    McDowell, Ben
    Peixoto, Nathalia
    2018 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2018, : 13 - 17
  • [39] Voltage analysis after multi-electrode ablation with duty-cycled bipolar and unipolar radiofrequency energy: a case report
    Boersma, Lucas
    Mulder, Anton
    Jansen, Ward
    Wever, Eric
    Wijffels, Maurits
    EUROPACE, 2009, 11 (11): : 1546 - 1548
  • [40] The analysis of electrode-recording-horizon in multi-electrode array(MEA)
    Lin, Yunsheng
    Chen, Chuanping
    Chen, Lin
    Zeng, Shaoqun
    Luo, Qingming
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 7345 - 7348