Atrial fibrosis identification with unipolar electrogram eigenvalue distribution analysis in multi-electrode arrays

被引:3
|
作者
Riccio, Jennifer [1 ]
Alcaine, Alejandro [2 ,3 ]
Rocher, Sara [4 ]
Martinez-Mateu, Laura [5 ]
Saiz, Javier [4 ]
Invers-Rubio, Eric [6 ]
Guillem, Maria S. [7 ]
Pablo Martinez, Juan [1 ,8 ]
Laguna, Pablo [1 ,8 ]
机构
[1] Univ Zaragoza, Aragon Inst Engn Res I3A, BSICoS Grp, Zaragoza, Spain
[2] Univ San Jorge, Fac Ciencias Salud, CoMBA Grp, Zaragoza, Spain
[3] Univ San Jorge, Fac Ciencias Salud, BSICoS Grp, Zaragoza, Spain
[4] Univ Politecn Valencia, Ctr Invest & Innovac Ingn, Valencia, Spain
[5] Univ Rey Juan Carlos, Dept Teoria Senal & Comunicac Sistemas Telemat &, Madrid, Spain
[6] Hosp Clin Barcelona, IDIBAPS Inst, Barcelona, Spain
[7] Univ Politecn Valencia, ITACA Inst, Valencia, Spain
[8] Ctr Invest Biomed Red Bioingn Biomat & Nanomed CI, Zaragoza, Spain
关键词
Atrial fibrosis; Atrial fibrillation (AF); Bipolar electrograms (b-EGMs); Eigenvalue dominance ratio (EIGDR); Unipolar electrograms (u-EGMs); IONIC MECHANISMS; FIBRILLATION; COMPONENT; ABLATION; MYOCYTES; CURRENTS;
D O I
10.1007/s11517-022-02648-3
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Atrial fibrosis plays a key role in the initiation and progression of atrial fibrillation (AF). Atrial fibrosis is typically identified by a peak-to-peak amplitude of bipolar electrograms (b-EGMs) lower than 0.5 mV, which may be considered as ablation targets. Nevertheless, this approach disregards signal spatiotemporal information and b-EGM sensitivity to catheter orientation. To overcome these limitations, we propose the dominant-to-remaining eigenvalue dominance ratio (EIGDR) of unipolar electrograms (u-EGMs) within neighbor electrode cliques as a waveform dispersion measure, hypothesizing that it is correlated with the presence of fibrosis. A simulated 2D tissue with a fibrosis patch was used for validation. We computed EIGDR maps from both original and time-aligned u-EGMs, denoted as R and R-A, respectively, also mapping the gain in eigenvalue concentration obtained by the alignment, Delta R-A. The performance of each map in detecting fibrosis was evaluated in scenarios including noise and variable electrode-tissue distance. Best results were achieved by R-A, reaching 94% detection accuracy, versus the 86% of b-EGMs voltage maps. The proposed strategy was also tested in real u-EGMs from fibrotic and non- fibrotic areas over 3D electroanatomical maps, supporting the ability of the EIGDRs as fibrosis markers, encouraging further studies to confirm their translation to clinical settings.
引用
收藏
页码:3091 / 3112
页数:22
相关论文
共 50 条
  • [41] Use of coupled multi-electrode arrays to advance the understanding of selected corrosion phenomena
    Budiansky, N. D.
    Bocher, F.
    Cong, H.
    Hurley, M. F.
    Scully, J. R.
    CORROSION, 2007, 63 (06) : 537 - 554
  • [42] Network dynamics of living neuronal networks cultured on multi-electrode arrays.
    Kudoh, SN
    Taguchi, T
    SICE 2003 ANNUAL CONFERENCE, VOLS 1-3, 2003, : 3310 - 3313
  • [43] Electric crosstalk impairs spatial resolution of multi-electrode arrays in retinal implants
    Wilke, R. G. H.
    Moghadam, G. Khalili
    Lovell, N. H.
    Suaning, G. J.
    Dokos, S.
    JOURNAL OF NEURAL ENGINEERING, 2011, 8 (04)
  • [44] Conventional radiofrequency catheter ablation compared to multi-electrode ablation for atrial fibrillation
    Gal, Pim
    Aarntzen, Alissa E. S. M.
    Smit, Jaap Jan J.
    Adiyaman, Ahmet
    Misier, Anand R. Ramdat
    Delnoy, Peter Paul H. M.
    Elvan, Arif
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 176 (03) : 891 - 895
  • [45] Atrial Fibrosis Hampers Non-invasive Localization of Atrial Ectopic Foci From Multi-Electrode Signals: A 3D Simulation Study
    Jorge Godoy, Eduardo
    Lozano, Miguel
    Garcia-Fernandez, Ignacio
    Ferrer-Albero, Ana
    MacLeod, Rob
    Saiz, Javier
    Sebastian, Rafael
    FRONTIERS IN PHYSIOLOGY, 2018, 9
  • [46] Magnetically reshapable 3D multi-electrode arrays of liquid metals for electrophysiological analysis of brain organoids
    Kim, Enji
    Jeong, Eunseon
    Hong, Yeon-Mi
    Jeong, Inhea
    Kim, Junghoon
    Kwon, Yong Won
    Park, Young-Geun
    Lee, Jiin
    Choi, Suah
    Kim, Ju-Young
    Lee, Jae-Hyun
    Cho, Seung-Woo
    Park, Jang-Ung
    NATURE COMMUNICATIONS, 2025, 16 (01)
  • [47] Multi-Electrode Arrays Modified with Bimetallic Nanoparticles; Electrical Performance and Neural Signal Recording
    Kim, Yong Hee
    Kim, Gook Hwa
    Kim, Ah Young
    Jung, Sang-Don
    2015 IEEE 15TH INTERNATIONAL CONFERENCE ON NANOTECHNOLOGY (IEEE-NANO), 2015, : 238 - 241
  • [48] Longevity and reliability of chronic unit recordings using the Utah, intracortical multi-electrode arrays
    Sponheim, Caleb
    Papadourakis, Vasileios
    Collinger, Jennifer L.
    Downey, John
    Weiss, Jeffrey
    Pentousi, Lida
    Elliott, Kaisa
    Hatsopoulos, Nicholas G.
    JOURNAL OF NEURAL ENGINEERING, 2021, 18 (06)
  • [49] Are Multi-electrode Arrays able to Differentiate Anatomical from Functional Reentries in an Excitable Sheet?
    Martinez, Laura
    Jalife, Jose
    Berenfeld, Omer
    Saiz, Javier
    2015 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2015, 42 : 865 - 868
  • [50] Electro-chemical and biological properties of carbon nanotube based multi-electrode arrays
    Gabay, Tamir
    Ben-David, Moti
    Kalifa, Itshak
    Sorkin, Raya
    Abrams, Ze'ev R.
    Ben-Jacob, Eshel
    Hanein, Yael
    NANOTECHNOLOGY, 2007, 18 (03)