A 96-well screen filter plate for high-throughput biological sample preparation and LC-MS/MS analysis

被引:14
|
作者
Peng, SX [1 ]
Cousineau, M [1 ]
Juzwin, SJ [1 ]
Ritchie, DM [1 ]
机构
[1] Johnson & Johnson Pharmaceut Res & Dev, Raritan, NJ 08869 USA
关键词
D O I
10.1021/ac051514p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel 96-well screen filter plate (patent pending) has been invented to eliminate a time-consuming and labor-intensive step in preparation of in vivo study samples-to remove blood or plasma clots. These clots plug the pipet tips during a manual or automated sample-transfer step causing inaccurate pipetting or total pipetting failure. Traditionally, these blood and plasma clots are removed by picking them out manually one by one from each sample tube before any sample transfer can be made. This has significantly slowed the sample preparation process and has become a bottleneck for automated high-throughput sample preparation using robotic liquid handlers. Our novel screen filter plate was developed to solve this problem. The 96-well screen filter plate consists of 96 stainless steel wire-mesh screen tubes connected to the 96 openings of a top plate so that the screen filter plate can be readily inserted into a 96-well sample storage plate. Upon insertion, the blood and plasma clots are excluded from entering the screen tube while clear sample solutions flow freely into it. In this way, sample transfer can be easily completed by either manual or automated pipetting methods. In this report, three structurally diverse compounds were selected to evaluate and validate the use of the screen filter plate. The plasma samples of these compounds were transferred and processed in the presence and absence of the screen filter plate and then analyzed by LC-MS/MS methods. Our results showed a good agreement between the samples prepared with and without the screen filter plate, demonstrating the utility and efficiency of this novel device for preparation of blood and plasma samples. The device is simple, easy to use, and reusable. It can be employed for sample preparation of other biological fluids that contain floating particulates or aggregates.
引用
收藏
页码:343 / 348
页数:6
相关论文
共 50 条
  • [31] Fast and high-throughput LC-MS characterization, and peptide mapping of engineered AAV capsids using LC-MS/MS
    Lam, Anh K.
    Zhang, Junping
    Frabutt, Dylan
    Mulcrone, Patrick L.
    Li, Lei
    Zeng, Lifan
    Herzog, Roland W.
    Xiao, Weidong
    MOLECULAR THERAPY-METHODS & CLINICAL DEVELOPMENT, 2022, 27 : 185 - 194
  • [32] Analysis of biopharmaceutical proteins in biological matrices by LC-MS/MS I. Sample preparation
    Bischoff, Rainer
    Bronsema, Kees J.
    van de Merbel, Nico C.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2013, 48 : 41 - 51
  • [33] Automated LC-MS analysis and data extraction for high-throughput chemistry
    Mason, Joseph
    Wilders, Harry
    Fallon, David J.
    Thomas, Ross P.
    Bush, Jacob T.
    Tomkinson, Nicholas C. O.
    Rianjongdee, Francesco
    DIGITAL DISCOVERY, 2023, 2 (06): : 1894 - 1899
  • [34] A Protein Preparation Method for the High-throughput Identification of Proteins Interacting with a Nuclear Cofactor Using LC-MS/MS Analysis
    Tsuchiya, Megumi
    Karim, M. Rezaul
    Matsumoto, Taro
    Ogawa, Hidesato
    Taniguchi, Hiroaki
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2017, (119):
  • [35] DBS direct elution: optimizing performance in high-throughput quantitative LC-MS/MS analysis
    Abu-Rabie, Paul
    Spooner, Neil
    Chowdhry, Babur Z.
    Pullen, Frank S.
    BIOANALYSIS, 2015, 7 (16) : 2003 - 2017
  • [36] High-throughput protein identification of complex mixtures by LC-MS/MS.
    Patterson, SD
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1999, 217 : U151 - U151
  • [37] Automated solid-phase extraction of atenolol from human urine for high throughput LC-MS-MS analysis using a strata™-X 96-well plate
    Huq, Shahana Wahab
    Kallury, Krishna
    LC GC NORTH AMERICA, 2007, : 62 - 62
  • [38] Screen-Printed Electrochemical 96-Well Plate: a High-Throughput Platform for Multiple Analytical Applications
    Neves, M. M. P. S.
    Gonzalez-Garcia, M. B.
    Hernandez-Santos, D.
    Fanjul-Bolado, P.
    ELECTROANALYSIS, 2014, 26 (12) : 2764 - 2772
  • [39] An efficient and green method for the analysis of synthetic cathinones in whole blood using 96-well electromembrane extraction and LC-MS/MS
    Fabris, Andre L.
    Hansen, Frederik A.
    Yonamine, Mauricio
    Pedersen-Bjergaard, Stig
    Oiestad, Elisabeth L.
    SUSTAINABLE CHEMISTRY AND PHARMACY, 2024, 38