A 96-well screen filter plate for high-throughput biological sample preparation and LC-MS/MS analysis

被引:14
|
作者
Peng, SX [1 ]
Cousineau, M [1 ]
Juzwin, SJ [1 ]
Ritchie, DM [1 ]
机构
[1] Johnson & Johnson Pharmaceut Res & Dev, Raritan, NJ 08869 USA
关键词
D O I
10.1021/ac051514p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel 96-well screen filter plate (patent pending) has been invented to eliminate a time-consuming and labor-intensive step in preparation of in vivo study samples-to remove blood or plasma clots. These clots plug the pipet tips during a manual or automated sample-transfer step causing inaccurate pipetting or total pipetting failure. Traditionally, these blood and plasma clots are removed by picking them out manually one by one from each sample tube before any sample transfer can be made. This has significantly slowed the sample preparation process and has become a bottleneck for automated high-throughput sample preparation using robotic liquid handlers. Our novel screen filter plate was developed to solve this problem. The 96-well screen filter plate consists of 96 stainless steel wire-mesh screen tubes connected to the 96 openings of a top plate so that the screen filter plate can be readily inserted into a 96-well sample storage plate. Upon insertion, the blood and plasma clots are excluded from entering the screen tube while clear sample solutions flow freely into it. In this way, sample transfer can be easily completed by either manual or automated pipetting methods. In this report, three structurally diverse compounds were selected to evaluate and validate the use of the screen filter plate. The plasma samples of these compounds were transferred and processed in the presence and absence of the screen filter plate and then analyzed by LC-MS/MS methods. Our results showed a good agreement between the samples prepared with and without the screen filter plate, demonstrating the utility and efficiency of this novel device for preparation of blood and plasma samples. The device is simple, easy to use, and reusable. It can be employed for sample preparation of other biological fluids that contain floating particulates or aggregates.
引用
收藏
页码:343 / 348
页数:6
相关论文
共 50 条
  • [1] High-throughput protein precipitation method with 96-well plate for determination of doxepin and nordoxepin in human plasma using LC-MS/MS
    Margaryan, Tigran
    Sargsyan, Mariam
    Gevorgyan, Arpine
    Zakaryan, Hasmik
    Aleksanyan, Armine
    Harutyunyan, Armen
    Armoudjian, Yeghig
    Mikayelyan, Astghik
    BIOMEDICAL CHROMATOGRAPHY, 2020, 34 (08)
  • [2] An Automated High-Throughput Sample Preparation Protocol for LC-MS/MS Analysis of Glycopeptides
    Arul, Albert-Baskar
    Park, Jong-Moon
    Lee, Hookeun
    Baek, Jeong-Heum
    Jeon, Jongho
    Ji, Eunhee
    Oh, Jae Won
    Kim, Kwang Pyo
    CURRENT PROTEOMICS, 2016, 13 (01) : 55 - 60
  • [3] Development of an automated high-throughput sample preparation protocol for LC-MS/MS analysis of glycated peptides
    Jeon, Jongho
    Yang, Jiwon
    Park, Jong-Moon
    Han, Na-Young
    Lee, Yeong-Bae
    Lee, Hookeun
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1092 : 88 - 94
  • [4] Automated sample preparation and LC-MS for high-throughput ADME quantification
    O'Connor, D
    CURRENT OPINION IN DRUG DISCOVERY & DEVELOPMENT, 2002, 5 (01) : 52 - 58
  • [5] High-Throughput Analysis of Sofalcone in Human Plasma by Use of Automated 96-Well Protein Precipitation and LC-MS-MS
    Hohyun Kim
    Moon Sun Jang
    Jung-Ae Lee
    Dongjin Pyo
    Hye-Ran Yoon
    Hee Joo Lee
    Kyung Ryul Lee
    Chromatographia, 2004, 60 : 335 - 339
  • [6] High-throughput analysis of sofalcone in human plasma by use of automated 96-well protein precipitation and LC-MS-MS
    Kim, H
    Jang, MS
    Lee, JA
    Pyo, D
    Yoon, HR
    Lee, HJ
    Lee, KR
    CHROMATOGRAPHIA, 2004, 60 (5-6) : 335 - 339
  • [7] High-throughput LC-MS/MS method with 96-well plate precipitation for the determination of arotinolol and amlodipine in a small volume of rat plasma: Application to a pharmacokinetic interaction study
    Qian, Zheyuan
    Le, Jian
    Chen, Xiujuan
    Li, Shengni
    Song, Hongjie
    Hong, Zhanying
    JOURNAL OF SEPARATION SCIENCE, 2018, 41 (03) : 618 - 629
  • [8] A high-throughput sample preparation method for cellular proteomics using 96-well filter plates
    Switzar, Linda
    van Angeren, Jordy
    Pinkse, Martijn
    Kool, Jeroen
    Niessen, Wilfried M. A.
    PROTEOMICS, 2013, 13 (20) : 2980 - 2983
  • [9] Fast LC for high-throughput LC-MS
    Wehr, T
    LC GC NORTH AMERICA, 2003, : 75 - 78
  • [10] Fast LC for high-throughput LC-MS
    Wehr, T
    LC GC NORTH AMERICA, 2002, 20 (01) : 40 - +