An efficient and green method for the analysis of synthetic cathinones in whole blood using 96-well electromembrane extraction and LC-MS/MS

被引:2
|
作者
Fabris, Andre L. [1 ]
Hansen, Frederik A. [2 ]
Yonamine, Mauricio [1 ]
Pedersen-Bjergaard, Stig [2 ,3 ]
Oiestad, Elisabeth L. [2 ,4 ]
机构
[1] Univ Sao Paulo, Sch Pharmaceut Sci, Ave Prof Lineu Prestes 580, Sao Paulo, Brazil
[2] Univ Oslo, Dept Pharm, Blindern, N-0316 Oslo, Norway
[3] Univ Copenhagen, Fac Hlth & Med Sci, Dept Pharm, Univ Pk 2, DK-2100 Copenhagen, Denmark
[4] Oslo Univ Hosp, Div Lab Med, Dept Forens Sci, Oslo N-0424, Norway
来源
关键词
Electromembrane extraction; Synthetic cathinones; New psycoactive substances; LC-MS/MS; PSYCHOACTIVE SUBSTANCES; LIQUID-MEMBRANES; AUTOMATION; PLASMA;
D O I
10.1016/j.scp.2024.101494
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Electromembrane extraction (EME) is a miniaturized technique in which charged molecules are extracted from biological samples, through a porous membrane, into an acceptor solution. This process occurs in the presence of an electric field that enables increased analyte recovery in short extraction times. Studies are being carried out to establish recommended extraction conditions for different groups of compounds based on their physicochemical properties. In this work, pre-established generic liquid membranes for the extraction of basic compounds were tested using synthetic cathinones within a wide log P range as basic model analytes. First, recommended organic solvents for the chosen analytes were evaluated in terms of recovery. The best candidates were included in an optimization study with other relevant EME conditions (voltage, extraction time, and agitation rate). All analyses were performed using a UPLC-MS/MS with the multiple reaction monitoring mode. 2-Undecanone was chosen as the liquid membrane providing the best extraction efficiency in combination with 40 V, 35 min, and 725 rpm. Validation showed r(2) > 0.99 in the 1-500 ng/mL range, accuracy of +/- 12%, imprecision of <= 19%, 1 ng/mL as limit of quantitation, 0.1-0.5 ng/mL as limit of detection, matrix effect 97-118%, and recovery 63-110%. Among the generic liquid membranes studied in this work, 2-Undecanone was the best choice for the target basic analytes. High recoveries and low matrix effects were achieved, thus demonstrating the applicability of recommended generic liquid membranes in the 96-well plate setup and with whole blood samples. Our findings contribute to further establishing EME as an actual sample preparation technique for routine analyses that could be further explored in a commercial format.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Determination of tryptamine analogs in whole blood by 96-well electromembrane extraction and UHPLC-MS/MS
    Schueller, Maria
    McQuade, Tao Angell -Petersen
    Bergh, Marianne Skov-Skov
    Pedersen-Bjergaard, Stig
    Oiestad, Elisabeth Leere
    TALANTA OPEN, 2023, 7
  • [2] A single extraction 96-well method for LC-MS/MS quantification of urinary eicosanoids, steroids and drugs
    Sieminska, Julia
    Kolmert, Johan
    Zurita, Javier
    Benkestock, Kurt
    Revol-Cavalier, Johanna
    Niklinski, Jacek
    Reszec, Joanna
    Dahlen, Sven-Erik
    Ciborowski, Michal
    Wheelock, Craig E.
    PROSTAGLANDINS & OTHER LIPID MEDIATORS, 2024, 170
  • [3] A LC-MS/MS method for the determination of common synthetic cathinones in meconium
    Lopez-Rabunal, Angela
    Lendoiro, Elena
    Concheiro, Marta
    Lopez-Rivadulla, Manuel
    Cruz, Angelines
    de-Castro-Rios, Ana
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1124 : 349 - 355
  • [4] Sensitive and effective method with 96-well plate for determination of levamlodipine in human plasma using LC-MS/MS
    Dong, Lingfang
    Li, Kun
    Gao, Shan
    Wang, Wenyi
    Feng, Yinghua
    Zhang, Jingying
    Yang, Jie
    Dong, Weifeng
    Zhang, Wei
    ANALYTICAL BIOCHEMISTRY, 2024, 691
  • [5] Determination of potato carboxypeptidase inhibitor in African Green Monkey plasma using 96-well SPE and LC-MS/MS
    Rose, MJ
    Fernandez-Metzler, C
    Johns, BA
    Sitko, GR
    Cook, JJ
    Yergey, J
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 38 (04) : 695 - 702
  • [6] A new approach to the application of solid phase extraction disks with LC-MS/MS for the analysis of drugs on a 96-well plate format
    Cudjoe, Erasmus
    Pawliszyn, Janusz
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 50 (04) : 556 - 562
  • [7] Development and validation of a chiral LC-MS/MS method for the separation and quantification of four synthetic cathinones in human whole blood and its application in stability analysis
    Aldubayyan A.A.
    Castrignanò E.
    Elliott S.
    Abbate V.
    Talanta, 2023, 253
  • [8] A LC-MS/MS method for determination of 73 synthetic cathinones and related metabolites in urine
    Fan, Shu-Yu
    Zang, Chi-Zong
    Shih, Po-Han
    Ko, Ya-Chun
    Hsu, Ya-Hui
    Lin, Mei-Chih
    Tseng, Su-Hsiang
    Wang, Der-Yuan
    FORENSIC SCIENCE INTERNATIONAL, 2020, 315
  • [9] Fast determination of amphetamine-type stimulants and synthetic cathinones in whole blood samples using protein precipitation and LC-MS/MS
    Cunha, Ricardo Leal
    Lima Oliveira, Celinalva da Silva
    de Oliveira, Aline Lima
    Maldaner, Adriano Otavio
    Pereira, Pedro Afonso P.
    MICROCHEMICAL JOURNAL, 2021, 163
  • [10] Sensitive determination of erdosteine in human plasma by use of automated 96-well solid-phase extraction and LC-MS/MS
    Kim, HY
    Chang, KY
    Lee, HJ
    Han, SB
    Lee, KR
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 34 (03) : 661 - 669