Ultrasensitive determination of amoxicillin using chemiluminescence with flow injection analysis

被引:7
|
作者
Xie, XF [1 ]
Song, ZH [1 ]
机构
[1] NW Univ Xian, Dept Chem, Xian 710069, Peoples R China
来源
SPECTROSCOPY-AN INTERNATIONAL JOURNAL | 2006年 / 20卷 / 01期
关键词
D O I
10.1155/2006/270417
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Results presented here reveal that amoxicillin can greatly enhance the chemiluminescence intensity generated from the reaction between luminol and hydrogen peroxide. The increment chemiluminescence signal was linearly dependent on amoxicillin concentration in the range from 10 pg center dot ml(-1) to 2 ng center dot ml(-1) (r(2) = 0.9978) offering a detection limit as low as 3.5 pg center dot ml(-1) (3 sigma). At a flow rate of 2.0 ml center dot min(-1), one analysis cycle, including sampling and washing, can be accomplished in 20 s with a relative standard deviation of less than 5%. The sensitive flow injection method was applied successfully to determine of amoxicillin in pharmaceutical preparations, human urine and serum without any pretreatment procedure, with recovery from 90.0% to 110.0% and relative standard deviations of less than 5.0%.
引用
收藏
页码:37 / 43
页数:7
相关论文
共 50 条
  • [11] Determination of riboflavin using flow injection inhibitory chemiluminescence
    Song, ZH
    Wang, L
    ANALYTICAL LETTERS, 2000, 33 (13) : 2767 - 2778
  • [12] Determination of methyltestosterone using flow injection with chemiluminescence detection
    Xie, ZH
    Ouyang, XQ
    Guo, LQ
    Lin, XC
    Chen, GN
    LUMINESCENCE, 2005, 20 (03) : 231 - 235
  • [13] FLOW INJECTION ANALYSIS CHEMILUMINESCENCE DETERMINATION OF HYDROXYLAMINE HYDROCHLORIDE
    Baezzat, Mohammad Reza
    Izadpanah, Maryam
    BIOLUMINESCENCE AND CHEMILUMINESCENCE, 2009, : 173 - 176
  • [14] Determination of dipyridamole by flow injection analysis with chemiluminescence detection
    Yang, ML
    Li, LQ
    Feng, ML
    Lü, JR
    Zhang, ZJ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 28 (02) : 161 - 163
  • [15] Determination of hydroxycamptothecinum by flow injection analysis with chemiluminescence detection
    Li Liqing
    Lin, Guan
    Ming, Su
    Sun Hanwen
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2007, 21 (06) : 356 - 362
  • [16] Determination of isoniazid by flow-injection chemiluminescence analysis
    Qu, P
    Li, BX
    Zhang, ZJ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (05) : 665 - 667
  • [17] Determination of norfloxacin by flow injection analysis with chemiluminescence detection
    Sun, Han-wen
    Li, Li-qing
    Chen, Xue-yan
    Shi, Hong-mei
    Lue, Yun-kai
    CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2006, 51 (02): : 100 - 107
  • [18] Ethanol determination by the flow injection analysis, with chemiluminescence detection
    Danet, AF
    Badea, M
    Jipa, S
    REVISTA DE CHIMIE, 1997, 48 (08): : 726 - 731
  • [19] Determination of riboflavin by flow injection analysis with chemiluminescence detection
    Kao Teng Hsueh Hsiao Hua Heush Hsueh Pao, 5 Suppl (354):
  • [20] DETERMINATION OF PARACETAMOL USING A FLOW INJECTION ANALYSIS WITH MULTICOMMUTATION AND CHEMILUMINESCENCE DETECTION.
    Oliveira, Geiser G.
    Janegitz, Bruno C.
    Batistao, Marina B.
    Salami, Fernanda H.
    Fatibello-Filho, Orlando
    Leite, Oldair D.
    QUIMICA NOVA, 2009, 32 (07): : 1755 - 1759