Ultrasensitive determination of amoxicillin using chemiluminescence with flow injection analysis

被引:7
|
作者
Xie, XF [1 ]
Song, ZH [1 ]
机构
[1] NW Univ Xian, Dept Chem, Xian 710069, Peoples R China
来源
SPECTROSCOPY-AN INTERNATIONAL JOURNAL | 2006年 / 20卷 / 01期
关键词
D O I
10.1155/2006/270417
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Results presented here reveal that amoxicillin can greatly enhance the chemiluminescence intensity generated from the reaction between luminol and hydrogen peroxide. The increment chemiluminescence signal was linearly dependent on amoxicillin concentration in the range from 10 pg center dot ml(-1) to 2 ng center dot ml(-1) (r(2) = 0.9978) offering a detection limit as low as 3.5 pg center dot ml(-1) (3 sigma). At a flow rate of 2.0 ml center dot min(-1), one analysis cycle, including sampling and washing, can be accomplished in 20 s with a relative standard deviation of less than 5%. The sensitive flow injection method was applied successfully to determine of amoxicillin in pharmaceutical preparations, human urine and serum without any pretreatment procedure, with recovery from 90.0% to 110.0% and relative standard deviations of less than 5.0%.
引用
收藏
页码:37 / 43
页数:7
相关论文
共 50 条
  • [21] Determination of eugenol using flow injection analysis with potassium permanganate chemiluminescence detection
    Xu, Hun
    ISTM/2007: 7TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-7, CONFERENCE PROCEEDINGS, 2007, : 5109 - 5112
  • [22] Determination of copper complexation in seawater using flow injection analysis with chemiluminescence detection
    Zamzow, H
    Coale, KH
    Johnson, KS
    Sakamoto, CM
    ANALYTICA CHIMICA ACTA, 1998, 377 (2-3) : 133 - 144
  • [23] Ultrasensitive flow injection chemiluminescence detection of DNA hybridization using nanoCuS tags
    Ding, Caifeng
    Zhong, Hua
    Zhang, Shusheng
    BIOSENSORS & BIOELECTRONICS, 2008, 23 (08): : 1314 - 1318
  • [24] Flow injection chemiluminescence determination of tetracycline
    Townshend, A
    Ruengsitagoon, W
    Thongpoon, C
    Liawruangrath, S
    ANALYTICA CHIMICA ACTA, 2005, 541 (1-2) : 105 - 111
  • [25] Flow injection/chemiluminescence determination of cephradine
    Fan, SL
    Lü, C
    Zhou, QX
    Wang, J
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 29 (03) : 367 - 367
  • [26] Determination of urapidil by flow injection chemiluminescence
    Lang, HY
    Li, YR
    Zhang, WP
    Zhang, XJ
    Shen, YH
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2003, 24 (04): : 618 - 620
  • [27] Determination of hydrazine by flow injection with chemiluminescence
    Lv, JG
    Huang, YM
    Zhang, ZJ
    ANALYTICAL LETTERS, 2001, 34 (08) : 1323 - 1330
  • [28] Flow injection chemiluminescence determination of pyrogallol
    Safavi, A
    Baezzat, MR
    ANALYTICA CHIMICA ACTA, 1998, 368 (1-2) : 113 - 116
  • [29] Chemiluminescence flow injection determination of bismuth
    Baezzat, Mohammad R.
    Bahrani, Roza
    LUMINESCENCE, 2010, 25 (02) : 106 - 106
  • [30] Flow injection chemiluminescence determination of paracetamol
    Ruengsitagoon, Wirat
    Liawruangrath, Saisunee
    Townshend, Alan
    TALANTA, 2006, 69 (04) : 976 - 983