Modified look-locker inversion recovery T1 mapping indices: assessment of accuracy and reproducibility between magnetic resonance scanners

被引:59
|
作者
Raman, Fabio S. [1 ]
Kawel-Boehm, Nadine [1 ,2 ]
Gai, Neville [1 ]
Freed, Melanie [3 ]
Han, Jing [4 ]
Liu, Chia-Ying [1 ]
Lima, Joao A. C. [5 ]
Bluemke, David A. [1 ,6 ]
Liu, Songtao [1 ,6 ]
机构
[1] NIH, Ctr Clin, Bethesda, MD 20892 USA
[2] Univ Basel Hosp, Clin Radiol & Nucl Med, CH-4031 Basel, Switzerland
[3] NYU, Sch Med, New York, NY USA
[4] US FDA, Rockville, MD 20857 USA
[5] Johns Hopkins Univ, Sch Med, Div Cardiol, Baltimore, MD USA
[6] Natl Inst Biomed Imaging & Bioengn, Mol Biomed Imaging Lab, Bethesda, MD USA
基金
美国国家卫生研究院;
关键词
T1; mapping; Partition coefficient (lambda); Extracellular volume fraction (ECV); Diffuse myocardial fibrosis; Modified look-locker with inversion recovery (MOLLI); DIFFUSE MYOCARDIAL FIBROSIS; EXTRACELLULAR VOLUME FRACTION; INTRAINDIVIDUAL ASSESSMENT; GD-DTPA; VALIDATION; QUANTIFICATION; ASSOCIATION; RELAXATION; INFARCTION; SHMOLLI;
D O I
10.1186/1532-429X-15-64
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Cardiovascular magnetic resonance (CMR) T1 mapping indices, such as T1 time and partition coefficient (lambda), have shown potential to assess diffuse myocardial fibrosis. The purpose of this study was to investigate how scanner and field strength variation affect the accuracy and precision/reproducibility of T1 mapping indices. Methods: CMR studies were performed on two 1.5T and three 3T scanners. Eight phantoms were made to mimic the T1/T2 of pre- and post-contrast myocardium and blood at 1.5T and 3T. T1 mapping using MOLLI was performed with simulated heart rate of 40-100 bpm. Inversion recovery spin echo (IR-SE) was the reference standard for T1 determination. Accuracy was defined as the percent error between MOLLI and IR-SE, and scan/re-scan reproducibility was defined as the relative percent mean difference between repeat MOLLI scans. Partition coefficient was estimated by Delta R1myocardium phantom/Delta R1blood phantom. Generalized linear mixed model was used to compare the accuracy and precision/reproducibility of T1 and lambda across field strength, scanners, and protocols. Results: Field strength significantly affected MOLLI T1 accuracy (6.3% error for 1.5T vs. 10.8% error for 3T, p<0.001) but not lambda accuracy (8.8% error for 1.5T vs. 8.0% error for 3T, p=0.11). Partition coefficients of MOLLI were not different between two 1.5T scanners (47.2% vs. 47.9%, p=0.13), and showed only slight variation across three 3T scanners (49.2% vs. 49.8% vs. 49.9%, p=0.016). Partition coefficient also had significantly lower percent error for precision (better scan/re-scan reproducibility) than measurement of individual T1 values (3.6% for lambda vs. 4.3%-4.8% for T1 values, approximately, for pre/post blood and myocardium values). Conclusion: Based on phantom studies, T1 errors using MOLLI ranged from 6-14% across various MR scanners while errors for partition coefficient were less (6-10%). Compared with absolute T1 times, partition coefficient showed less variability across platforms and field strengths as well as higher precision.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Modified look-locker inversion recovery T1 mapping indices: assessment of accuracy and reproducibility between magnetic resonance scanners
    Fabio S Raman
    Nadine Kawel-Boehm
    Neville Gai
    Melanie Freed
    Jing Han
    Chia-Ying Liu
    Joao AC Lima
    David A Bluemke
    Songtao Liu
    Journal of Cardiovascular Magnetic Resonance, 15
  • [2] Modified look-locker inversion recovery T1 mapping indices: assessment of accuracy and reproducibility between MRI scanners
    Fabio S Raman
    Nadine Kawel
    Neville Gai
    Melanie Freed
    Jing Han
    Peter Kellman
    Chia-Ying Liu
    Joao A Lima
    David A Bluemke
    Songtao Liu
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [3] Accuracy, Precision, and Reproducibility of Myocardial T1 Mapping: A Comparison of Four T1 Estimation Algorithms for Modified Look-Locker Inversion Recovery (MOLLI)
    Shao, Jiaxin
    Liu, Dapeng
    Sung, Kyunghyun
    Kim-Lien Nguyen
    Hu, Peng
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (05) : 1746 - 1756
  • [4] Fast calculation software for modified Look-Locker inversion recovery (MOLLI) T1 mapping
    Yoon-Chul Kim
    Khu Rai Kim
    Hyelee Lee
    Yeon Hyeon Choe
    BMC Medical Imaging, 21
  • [5] Effects of heart rate in modified look-locker inversion recovery (MOLLI) T1 mapping
    Yoshinori Suizuki
    Kunihiko Teraoka
    Yoshiaki Komori
    Andreas Greiser
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [6] Improved segmented modified Look-Locker inversion recovery T1 mapping sequence in mice
    Nezafat, Maryam
    Ramos, Isabel T.
    Henningsson, Markus
    Pratti, Andrea
    Basha, Tamer
    Botnar, Rene M.
    PLOS ONE, 2017, 12 (11):
  • [7] Fast calculation software for modified Look-Locker inversion recovery (MOLLI) T1 mapping
    Kim, Yoon-Chul
    Kim, Khu Rai
    Lee, Hyelee
    Choe, Yeon Hyeon
    BMC MEDICAL IMAGING, 2021, 21 (01)
  • [8] Modified Look-Locker inversion recovery (MOLLI) for high-resolution T1 mapping of the heart
    Messroghli, DR
    Radjenovic, A
    Kozerke, S
    Higgins, DM
    Sivananthan, MU
    Ridgway, JP
    MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (01) : 141 - 146
  • [9] Selection of magnetization catalyzation and readout methods for modified Look-Locker inversion recovery: A T1 mapping primer
    Cameron, Donnie
    Higgins, David M.
    Stehning, Christian
    Kouwenhoven, Marc
    Bouhrara, Mustapha
    Frenneaux, Michael P.
    Dawson, Dana K.
    Redpath, Thomas W.
    MAGNETIC RESONANCE IMAGING, 2015, 33 (04) : 363 - 373
  • [10] Modified look-locker inversion recovery (MOLLI) T1 mapping with inversion group (IG) fitting - A method for improved precision
    Sussman, Marshall S.
    Wintersperger, Bernd J.
    MAGNETIC RESONANCE IMAGING, 2019, 62 : 38 - 45