An energy transfer method for 4D Monte Carlo dose calculation

被引:42
|
作者
Siebers, Jeffrey V. [1 ]
Zhong, Hualiang [1 ]
机构
[1] Virginia Commonwealth Univ, Dept Radiat Oncol, Richmond, VA 23298 USA
关键词
four dimensional therapy; Monte Carlo; dose mapping;
D O I
10.1118/1.2968215
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This article presents a new method for four-dimensional Monte Carlo dose calculations which properly addresses dose mapping for deforming anatomy. The method, called the energy transfer method (ETM), separates the particle transport and particle scoring geometries: Particle transport takes place in the typical rectilinear coordinate system of the source image, while energy deposition scoring takes place in a desired reference image via use of deformable image registration. Dose is the energy deposited per unit mass in the reference image. ETM has been implemented into DOSXYZnrc and compared with a conventional dose interpolation method (DIM) on deformable phantoms. For voxels whose contents merge in the deforming phantom, the doses calculated by ETM are exactly the same as an analytical solution, contrasting to the DIM which has an average 1.1% dose discrepancy in the beam direction with a maximum error of 24.9% found in the penumbra of a 6 MV beam. The DIM error observed persists even if voxel subdivision is used. The ETM is computationally efficient and will be useful for 4D dose addition and benchmarking alternative 4D dose addition algorithms. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:4096 / 4105
页数:10
相关论文
共 50 条
  • [41] 3D dose distribution calculation in a voxelized human phantom by means of Monte Carlo method
    Abella, V.
    Miro, R.
    Juste, B.
    Verdu, G.
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (4-5) : 709 - 713
  • [42] Monte Carlo dose calculation on deforming anatomy
    Peterhans, Matthias
    Frei, Daniel
    Manser, Peter
    Aguirre, Mauricio Reyes
    Fix, Michael K.
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2011, 21 (02): : 113 - 123
  • [43] Experimental Verification of 4D Monte Carlo Simulations in a Deforming Anatomy
    Gholampourkashi, S.
    Cygler, J.
    Lavigne, B.
    Heath, E.
    MEDICAL PHYSICS, 2018, 45 (06) : E698 - E698
  • [44] 4D Monte Carlo Dose Calculations for Particle Therapy Combined with a Computational Biomechanical Model of Lung Motion
    Ishikawa, K. L.
    Takagi, S.
    Matthys, K.
    Wada, S.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [45] 4D Monte Carlo Based Patient-Specific Dose Reconstruction Incorporating Surface Motion Measurements
    Shiha, M.
    Cygler, J.
    Macrae, R.
    Gholampourkashi, S.
    Heath, E.
    MEDICAL PHYSICS, 2020, 47 (06) : E445 - E445
  • [46] Investigation of voxel warping and energy mapping approaches for fast 4D Monte Carlo dose calculations in deformed geometries using VMC++
    Heath, Emily
    Tessier, Frederic
    Kawrakow, Iwan
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (16): : 5187 - 5202
  • [47] Monte Carlo calculation method on low energy electronscattering in polybasic medium
    TAN Zhenyu 1 and HE Yancai 2 1. College of Electric Power
    2. Shanghai Institute of Ceramics
    Chinese Science Bulletin, 1998, (02) : 171 - 174
  • [48] CALCULATION OF ENERGY LIBERATION IN THE LOOP CHANNELS BY THE MONTE-CARLO METHOD
    ANTONOV, VA
    ARINKIN, FM
    BATYRBEKOV, GA
    BLYSKAVKA, AA
    SINYAVSKII, VV
    SOBOLEV, YA
    SOVIET ATOMIC ENERGY, 1982, 53 (05): : 778 - 781
  • [49] Domain-Division Monte Carlo Dose Calculation Method for Particle Therapy
    Ishikawa, Kl
    Niita, K.
    Takeda, K.
    Fukunishi, N.
    Takagi, S.
    MEDICAL PHYSICS, 2010, 37 (06) : 3284 - +
  • [50] The Use of Monte Carlo Method as An Independent Dose Verification Calculation Tool for TomoTherapy
    Chen, Q.
    Ding, K.
    Levinson, L.
    Read, P.
    Benedict, S.
    MEDICAL PHYSICS, 2012, 39 (06) : 3709 - 3709