An energy transfer method for 4D Monte Carlo dose calculation

被引:42
|
作者
Siebers, Jeffrey V. [1 ]
Zhong, Hualiang [1 ]
机构
[1] Virginia Commonwealth Univ, Dept Radiat Oncol, Richmond, VA 23298 USA
关键词
four dimensional therapy; Monte Carlo; dose mapping;
D O I
10.1118/1.2968215
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This article presents a new method for four-dimensional Monte Carlo dose calculations which properly addresses dose mapping for deforming anatomy. The method, called the energy transfer method (ETM), separates the particle transport and particle scoring geometries: Particle transport takes place in the typical rectilinear coordinate system of the source image, while energy deposition scoring takes place in a desired reference image via use of deformable image registration. Dose is the energy deposited per unit mass in the reference image. ETM has been implemented into DOSXYZnrc and compared with a conventional dose interpolation method (DIM) on deformable phantoms. For voxels whose contents merge in the deforming phantom, the doses calculated by ETM are exactly the same as an analytical solution, contrasting to the DIM which has an average 1.1% dose discrepancy in the beam direction with a maximum error of 24.9% found in the penumbra of a 6 MV beam. The DIM error observed persists even if voxel subdivision is used. The ETM is computationally efficient and will be useful for 4D dose addition and benchmarking alternative 4D dose addition algorithms. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:4096 / 4105
页数:10
相关论文
共 50 条
  • [31] 4D Monte Carlo dosimetry and its validation with measurements
    Park, K.
    Huang, T.
    Forster, K.
    Stevens, C.
    Zhang, G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S652 - S652
  • [32] 4D Monte Carlo Robustness Test for Proton Therapy
    Souris, K.
    Sterpin, E.
    Lee, J.
    MEDICAL PHYSICS, 2015, 42 (06) : 3615 - 3615
  • [33] A virtual photon energy fluence model for Monte Carlo dose calculation
    Fippel, M
    Haryanto, F
    Dohm, O
    Nüsslin, F
    Kriesen, S
    MEDICAL PHYSICS, 2003, 30 (03) : 301 - 311
  • [34] The regional Monte Carlo method: A dose calculation method based on accuracy requirement
    Woo, MK
    Scora, DJ
    Wong, E
    MEDICAL PHYSICS, 1998, 25 (10) : 1866 - 1871
  • [35] Monte carlo calculation for radiation dose prediction easily predicting monte carlo method for indoor radiation dose (part i)
    Omori T.
    Kato S.
    Kim M.
    Nukatsuka S.
    Journal of Environmental Engineering (Japan), 2016, 81 (727): : 835 - 843
  • [36] CALCULATION OF THE HYDRATION ENERGY OF ETHANOL BY THE MONTE-CARLO METHOD
    LEVCHUK, VN
    SHEYKHET, II
    SIMKIN, BY
    CHEMICAL PHYSICS LETTERS, 1991, 185 (3-4) : 339 - 343
  • [37] Basic features of the Monte Carlo method for dose calculation in radiation therapy
    Fippel, M.
    Nsslin, F.
    2001, Elsevier GmbH (11): : 73 - 82
  • [38] CALCULATION OF DOSE COMPOSITION OUTSIDE SHIELDING OF HIGH-ENERGY ACCELERATORS BY MONTE-CARLO METHOD
    MOKHOV, NV
    FROLOV, VV
    SOVIET ATOMIC ENERGY, 1975, 38 (04): : 288 - 290
  • [39] A general method to derive tissue parameters for Monte Carlo dose calculation with multi-energy CT
    Lalonde, Arthur
    Bouchard, Hugo
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (22): : 8044 - 8069
  • [40] Estimated Linear Energy Transfer and Depth Dose Profiles Through Combined Radioluminescence Imaging & Monte Carlo Calculation
    Rahman, M.
    Bruza, P.
    Zhang, R.
    Lin, Y.
    Langen, K.
    Gladstone, D.
    Pogue, B.
    MEDICAL PHYSICS, 2020, 47 (06) : E767 - E767