An energy transfer method for 4D Monte Carlo dose calculation

被引:42
|
作者
Siebers, Jeffrey V. [1 ]
Zhong, Hualiang [1 ]
机构
[1] Virginia Commonwealth Univ, Dept Radiat Oncol, Richmond, VA 23298 USA
关键词
four dimensional therapy; Monte Carlo; dose mapping;
D O I
10.1118/1.2968215
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This article presents a new method for four-dimensional Monte Carlo dose calculations which properly addresses dose mapping for deforming anatomy. The method, called the energy transfer method (ETM), separates the particle transport and particle scoring geometries: Particle transport takes place in the typical rectilinear coordinate system of the source image, while energy deposition scoring takes place in a desired reference image via use of deformable image registration. Dose is the energy deposited per unit mass in the reference image. ETM has been implemented into DOSXYZnrc and compared with a conventional dose interpolation method (DIM) on deformable phantoms. For voxels whose contents merge in the deforming phantom, the doses calculated by ETM are exactly the same as an analytical solution, contrasting to the DIM which has an average 1.1% dose discrepancy in the beam direction with a maximum error of 24.9% found in the penumbra of a 6 MV beam. The DIM error observed persists even if voxel subdivision is used. The ETM is computationally efficient and will be useful for 4D dose addition and benchmarking alternative 4D dose addition algorithms. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:4096 / 4105
页数:10
相关论文
共 50 条
  • [21] A Monte Carlo approach to the 4D scattering equations
    Farrow, Joseph A.
    JOURNAL OF HIGH ENERGY PHYSICS, 2018, (08):
  • [22] A Monte Carlo approach to the 4D scattering equations
    Joseph A. Farrow
    Journal of High Energy Physics, 2018
  • [23] Method for a motion model based automated 4D dose calculation
    Ziegler, Marc
    Brandt, Tobias
    Lettmaier, Sebastian
    Fietkau, Rainer
    Bert, Christoph
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (22):
  • [24] Study of Dose Calculation Using Monte Carlo Method in Radiotherapy
    Gao, C.
    Chi, Z.
    Liu, D.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [25] 4D Monte Carlo dose reconstructions using surface motion measurements: a feasibility study
    Shiha, Meaghen
    Cygler, Joanna E.
    MacRae, Robert
    Heath, Emily
    MEDICAL PHYSICS, 2022, 49 (08) : 5684 - 5684
  • [26] 4D Monte Carlo dose calculations in deforming anatomy using direct voxel tracking
    Heath, E
    Collins, L
    Seuntjens, J
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S45 - S45
  • [27] Validation of 4D Monte Carlo dose calculations using a programmable deformable lung phantom
    Gholampourkashi, Sara
    Cygler, Joanna E.
    Lavigne, Bernie
    Heath, Emily
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 76 : 16 - 27
  • [28] Use of a realistic breathing lung phantom to verify 4D Monte Carlo dose calculations
    Gholampourkashi, S.
    Cygler, J.
    Lavigne, B.
    Heath, E.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S45 - S46
  • [29] Statistical breathing curve sampling to quantify interplay effects of moving lung tumors in a 4D Monte Carlo dose calculation framework
    von Muenchow, Asmus
    Straub, Katrin
    Losert, Christoph
    Shpani, Roel
    Hofmaier, Jan
    Freislederer, Philipp
    Heinz, Christian
    Thieke, Christian
    Sohn, Matthias
    Alber, Markus
    Floca, Ralf
    Belka, Claus
    Parodi, Katia
    Reiner, Michael
    Kamp, Florian
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 101 : 104 - 111
  • [30] CALCULATION OF TRANSFER COEFFICIENTS OF RAREFIED GASES BY MONTE CARLO METHOD
    KOLESNIC.EG
    BAIBUZ, VF
    HIGH TEMPERATURE, 1968, 6 (06) : 963 - &