Signal Alteration of the Cochlear Perilymph on 3 Different Sequences after Intratympanic Gd-DTPA Administration at 3 Tesla: Comparison of 3D-FLAIR, 3D-T1-weighted Imaging, and 3D-CISS

被引:10
|
作者
Yamazaki, Masahiro [1 ]
Naganawa, Shinji [1 ]
Kawai, Hisashi [1 ]
Nihashi, Takashi [1 ]
Nakashima, Tsutomu [2 ]
机构
[1] Nagoya Univ, Grad Sch Med, Dept Radiol, Shouwa Ku, Nagoya, Aichi 4668550, Japan
[2] Nagoya Univ, Grad Sch Med, Dept Otorhinolaryngol, Shouwa Ku, Nagoya, Aichi 4668550, Japan
关键词
cochlea; FLAIR; high resolution; intratympanic gadolinium injection; magnetic resonance imaging; SENSORINEURAL HEARING-LOSS; MENIERES-DISEASE; ENDOLYMPHATIC HYDROPS; PROTEIN-CONCENTRATION; MIDDLE-EAR; FLUID; VISUALIZATION; DEXAMETHASONE; GENTAMICIN; DEAFNESS;
D O I
10.2463/mrms.9.65
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Three-dimensional fluid-attenuated inversion recovery (3D-FLAIR) imaging after intratympanic gadolinium injection is useful for pathophysiologic and morphologic analysis of the inner ear. However, statistical analysis of differences in inner ear signal intensity among 3D-FLAIR and other sequences has not been reported. We evaluated the signal intensity of cochlear fluid on each of 3D-FLAIR, 3D-T-1-weighted imaging (T1WI), and 3D-constructive interference in the steady state (CISS) to clarify the differences in contrast effect among these 3 sequences using intratympanic gadolinium injection. Methods: Twenty-one patients underwent 3D-FLAIR, 3D-T1WI, and 3D-CISS imaging at 3 tesla 24 hours after intratympanic injection of gadolinium. We determined regions of interest of the cochleae (C) and medulla oblongata (M) on each image, evaluated the signal intensity ratio between C and M (CM ratio), and determined the ratio of cochlear signal intensity of the injected side to that of the non-injected side (contrast value). Results: The CM ratio of the injected side (3.00 +/- 1.31, range, 0.53 to 4.88, on 3D-FLAIR; 0.83 +/- 0.30, range, 0.36 to 1.58 on 3D-T1WI) was significantly higher than that of the non-injected side (0.52 +/- 0.14, range, 0.30 to 0.76 on 3D-FLAIR; 0.49 +/- 0.11, range, 0.30 to 0.71 on 3D-T1WI) on 3D-FLAIR and 3D-T1WI (P < 0.001), although no significant difference was observed on 3D-CISS (10.03 +/- 2.19, range, 5.19 to 14.98, on the injected side; 9.52 +/- 1.63 range, 7.48 to 13.48, on the non-injected side) (P = 0.11). The mean contrast value on 3D-FLAIR (5.93 +/- 2.57, range, 1.22 to 11.05) was significantly higher than that on 3D-T1WI (1.73 +/- 0.60, range, 0.98 to 3.09) (P < 0.001). Conclusion: The 3D-FLAIR sequence is the most sensitive for observing alteration in inner ear fluid signal after intratympanic gadolinium injection. Our results warrant use of 3D-FLAIR as a sensitive imaging technique to clarify the pathological and morphological mechanisms of disorders of the inner ear.
引用
收藏
页码:65 / 71
页数:7
相关论文
共 50 条
  • [41] Comparison of T1-weighted 2D TSE, 3D SPGR, and two-point 3D Dixon MRI for automated segmentation of visceral adipose tissue at 3 Tesla
    Fallah, Faezeh
    Machann, Juergen
    Martirosian, Petros
    Bamberg, Fabian
    Schick, Fritz
    Yang, Bin
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2017, 30 (02) : 139 - 151
  • [42] Fluid signal suppression characteristics of 3D-FLAIR with a T2 selective inversion pulse in the skull base
    Naganawa, Shinji
    Kato, Yutaka
    Yoshida, Tadao
    Sone, Michihiko
    NATURE COMMUNICATIONS, 2023, 14 (01)
  • [43] 3D T2-weighted and Gd-EOB-DTPA-enhanced 3D T1-weighted MR cholangiography for evaluation of biliary anatomy in living liver donors
    Cai, Larry
    Yeh, Benjamin M.
    Westphalen, Antonio C.
    Roberts, John
    Wang, Zhen J.
    ABDOMINAL RADIOLOGY, 2017, 42 (03) : 842 - 850
  • [44] 3D T2-weighted and Gd-EOB-DTPA-enhanced 3D T1-weighted MR cholangiography for evaluation of biliary anatomy in living liver donors
    Larry Cai
    Benjamin M. Yeh
    Antonio C. Westphalen
    John Roberts
    Zhen J. Wang
    Abdominal Radiology, 2017, 42 : 842 - 850
  • [45] MRI diagnosis of saccular hydrops: Comparison of heavily-T2 FIESTA-C and 3D-FLAIR sequences with delayed acquisition
    Eliezer, Michael
    Poillon, Guillaume
    Horion, Julien
    Lelion, Phillipe
    Gerardin, Emmanuel
    Magne, Nicolas
    Gillibert, Andre
    Attye, Arnaud
    JOURNAL OF NEURORADIOLOGY, 2021, 48 (06) : 446 - 452
  • [46] Optimized 3D-FLAIR sequences to shorten the delay between intravenous administration of gadolinium and MRI acquisition in patients with Meniere's disease
    Barlet, Juliette
    Vaussy, Alexis
    Ejzenberg, Yohan
    Toupet, Michel
    Hautefort, Charlotte
    Gillibert, Andre
    Attye, Arnaud
    Eliezer, Michael
    EUROPEAN RADIOLOGY, 2022, 32 (10) : 6900 - 6909
  • [47] Comparison of the reproducibility of 2D and 3D amide proton transfer weighted imaging in intracranial rat gliomas at 3 T
    Chen, Xin
    Wei, Xinhua
    Liu, Lingling
    Yan, Xu
    Zhu, Xiaolei
    Xu, Xiangdong
    Jiang, Xinqing
    Liu, Zaiyi
    CHINESE JOURNAL OF ACADEMIC RADIOLOGY, 2020, 3 (01) : 59 - 64
  • [48] Comparison of the reproducibility of 2D and 3D amide proton transfer weighted imaging in intracranial rat gliomas at 3 T
    Xin Chen
    Xinhua Wei
    Lingling Liu
    Xu Yan
    Xiaolei Zhu
    Xiangdong Xu
    Xinqing Jiang
    Zaiyi Liu
    Chinese Journal of Academic Radiology, 2020, 3 : 59 - 64
  • [49] Quantification of Gd-DTPA concentration in neuroimaging using T1 3D MP-RAGE sequence at 3.0 T
    Xu, Fangjingwei
    Han, Hongbin
    Zhang, Hailong
    Pi, Jincai
    Fu, Yu
    MAGNETIC RESONANCE IMAGING, 2011, 29 (06) : 827 - 834
  • [50] Fat-suppressed 3D-T1-weighted-echo planar imaging: comparison with fat-suppressed 3D-T1-weighted-gradient echo in imaging the cartilage of the knee
    Karantanas, AH
    Zibis, AH
    Kitsoulis, P
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2002, 26 (03) : 159 - 165