Signal Alteration of the Cochlear Perilymph on 3 Different Sequences after Intratympanic Gd-DTPA Administration at 3 Tesla: Comparison of 3D-FLAIR, 3D-T1-weighted Imaging, and 3D-CISS

被引:10
|
作者
Yamazaki, Masahiro [1 ]
Naganawa, Shinji [1 ]
Kawai, Hisashi [1 ]
Nihashi, Takashi [1 ]
Nakashima, Tsutomu [2 ]
机构
[1] Nagoya Univ, Grad Sch Med, Dept Radiol, Shouwa Ku, Nagoya, Aichi 4668550, Japan
[2] Nagoya Univ, Grad Sch Med, Dept Otorhinolaryngol, Shouwa Ku, Nagoya, Aichi 4668550, Japan
关键词
cochlea; FLAIR; high resolution; intratympanic gadolinium injection; magnetic resonance imaging; SENSORINEURAL HEARING-LOSS; MENIERES-DISEASE; ENDOLYMPHATIC HYDROPS; PROTEIN-CONCENTRATION; MIDDLE-EAR; FLUID; VISUALIZATION; DEXAMETHASONE; GENTAMICIN; DEAFNESS;
D O I
10.2463/mrms.9.65
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Three-dimensional fluid-attenuated inversion recovery (3D-FLAIR) imaging after intratympanic gadolinium injection is useful for pathophysiologic and morphologic analysis of the inner ear. However, statistical analysis of differences in inner ear signal intensity among 3D-FLAIR and other sequences has not been reported. We evaluated the signal intensity of cochlear fluid on each of 3D-FLAIR, 3D-T-1-weighted imaging (T1WI), and 3D-constructive interference in the steady state (CISS) to clarify the differences in contrast effect among these 3 sequences using intratympanic gadolinium injection. Methods: Twenty-one patients underwent 3D-FLAIR, 3D-T1WI, and 3D-CISS imaging at 3 tesla 24 hours after intratympanic injection of gadolinium. We determined regions of interest of the cochleae (C) and medulla oblongata (M) on each image, evaluated the signal intensity ratio between C and M (CM ratio), and determined the ratio of cochlear signal intensity of the injected side to that of the non-injected side (contrast value). Results: The CM ratio of the injected side (3.00 +/- 1.31, range, 0.53 to 4.88, on 3D-FLAIR; 0.83 +/- 0.30, range, 0.36 to 1.58 on 3D-T1WI) was significantly higher than that of the non-injected side (0.52 +/- 0.14, range, 0.30 to 0.76 on 3D-FLAIR; 0.49 +/- 0.11, range, 0.30 to 0.71 on 3D-T1WI) on 3D-FLAIR and 3D-T1WI (P < 0.001), although no significant difference was observed on 3D-CISS (10.03 +/- 2.19, range, 5.19 to 14.98, on the injected side; 9.52 +/- 1.63 range, 7.48 to 13.48, on the non-injected side) (P = 0.11). The mean contrast value on 3D-FLAIR (5.93 +/- 2.57, range, 1.22 to 11.05) was significantly higher than that on 3D-T1WI (1.73 +/- 0.60, range, 0.98 to 3.09) (P < 0.001). Conclusion: The 3D-FLAIR sequence is the most sensitive for observing alteration in inner ear fluid signal after intratympanic gadolinium injection. Our results warrant use of 3D-FLAIR as a sensitive imaging technique to clarify the pathological and morphological mechanisms of disorders of the inner ear.
引用
收藏
页码:65 / 71
页数:7
相关论文
共 50 条
  • [31] Comparing lesion detection of infratentorial multiple sclerosis lesions between T2-weighted spin-echo, 2D-FLAIR, and 3D-FLAIR sequences
    Wang, Kevin Y.
    Uribe, Tomas A.
    Lincoln, Christie M.
    CLINICAL IMAGING, 2018, 51 : 229 - 234
  • [32] Leptomeningeal Enhancement Due to COVID-19 on 3D-FLAIR and T1 Black-Blood MR Imaging Sequences
    Velonakis, G.
    Karavasilis, E.
    Filippiadis, D. K.
    Almyroudi, M. P.
    Korompoki, E.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2021, 42 (07) : E39 - E41
  • [33] Determination of Efficiency of 3D Fluid-Attenuated Inversion Recovery (FLAIR) in the Imaging of Multiple Sclerosis in Comparison With 2D FLAIR at 3-Tesla MRI
    Kummari, Satyanarayana
    Burra, Kiran Goud
    Reddy, Vudem Ranjith Kumar
    Das, Saraswata
    Anilkumar, Challa
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (11)
  • [34] Evaluating agreement between mean upper cervical cord area measurements from 3d-flair and 3d-t1 brain images
    Costantini, G.
    Prados, F.
    Bosa, C.
    Pasanisi, M. B.
    Schillaci, V.
    Alteno, A.
    Ferraris, M.
    Gava, U.
    Chio, A.
    Vercellino, M.
    Cavalla, P.
    MULTIPLE SCLEROSIS JOURNAL, 2020, 26 (3_SUPPL) : 390 - 390
  • [35] Assessment of Cochlea Endolymphatic Hydrops Using 3-D FLAIR and 3-D Real IR Sequence in Guinea Pigs via 3T MRI After Intratympanic Gadolinium: A Histopathological Comparison
    Wang, Feng
    Lyu, Huiying
    Zhao, Menglong
    Sha, Yan
    Zhang, Fang
    Cheng, Yushu
    Huang, Wenhu
    Tang, Wenlin
    Xie, Youzhou
    Lu, Ping
    OTOLOGY & NEUROTOLOGY, 2017, 38 (04) : 585 - 590
  • [36] Comparison of post-contrast 3D-T1-MPRAGE, 3D-T1-SPACE and 3D-T2-FLAIR MR images in evaluation of meningeal abnormalities at 3-T MRI
    Jeevanandham, Balaji
    Kalyanpur, Tejas
    Gupta, Prashant
    Cherian, Mathew
    BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1074):
  • [37] Renal artery stenosis: 3D-phase-contrast MR angiography pre and post Gd-DTPA versus 3D-breathhold-ultrafast MR imaging
    Hahn, U
    Miller, S
    Naegele, T
    Schick, F
    Duda, SH
    Claussen, CD
    RADIOLOGY, 1997, 205 : 279 - 279
  • [38] Comparison of the contrast enhancement pattern in two different T1-weighted 3-D sequences in MR imaging of the breast
    Wiberg, MK
    Boné, B
    Bronge, L
    Aspelin, P
    ACTA RADIOLOGICA, 1998, 39 (06) : 680 - 685
  • [39] Fluid signal suppression characteristics of 3D-FLAIR with a T2 selective inversion pulse in the skull base
    Shinji Naganawa
    Yutaka Kato
    Tadao Yoshida
    Michihiko Sone
    Nature Communications, 14
  • [40] Comparison of T1-weighted 2D TSE, 3D SPGR, and two-point 3D Dixon MRI for automated segmentation of visceral adipose tissue at 3 Tesla
    Faezeh Fallah
    Jürgen Machann
    Petros Martirosian
    Fabian Bamberg
    Fritz Schick
    Bin Yang
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2017, 30 : 139 - 151