Determination of Efficiency of 3D Fluid-Attenuated Inversion Recovery (FLAIR) in the Imaging of Multiple Sclerosis in Comparison With 2D FLAIR at 3-Tesla MRI

被引:2
|
作者
Kummari, Satyanarayana [1 ]
Burra, Kiran Goud [2 ]
Reddy, Vudem Ranjith Kumar [3 ]
Das, Saraswata [4 ]
Anilkumar, Challa [1 ]
机构
[1] Great Eastern Med Sch & Hosp, Dept Radiol, Srikakulam, India
[2] Govt Dist Hosp, Dept Radiol, Medak, India
[3] Surabhi Inst Med Sci, Dept Radiol, Siddipet, India
[4] Coll Med & JNM Hosp, Dept Radiodiag, Kalyani, India
关键词
3-tesla mri; cnr; snr; comparison; mri; 3d-flair; 2d-flair; multiple sclerosis; FAST SPIN-ECHO; DIAGNOSTIC-CRITERIA; PULSE SEQUENCES; LESION LOAD; BRAIN; QUANTIFICATION; ARTIFACTS;
D O I
10.7759/cureus.48136
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: A fluid-attenuated inversion recovery (FLAIR) method eliminates the cerebrospinal fluid (CSF) signal, enhancing white matter lesion detection by enhancing the contrast between the lesion and CSF. Three-dimensional (3D) volume acquisition has the advantage of multiplanar reformation of contiguous slices yielding improved signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs). To our knowledge, there are only three studies comparing 3D-and 2D-FLAIR sequences with respect to multiple sclerosis (MS) lesions at 3 tesla.Aims and objectives: This study aimed to determine the efficiency of 3D-FLAIR in the detection of lesions of multiple sclerosis in terms of spatial and contrast resolutions in comparison with 2D-FLAIR sequences.Methodology: A total of 75 patients with MS undergoing magnetic resonance imaging (MRI) brain at the Department of Radiology, Krishna Institute of Medical Sciences (KIMS), Secunderabad, Telangana, India. This is an observational comparative study. Independent-samples t-tests were performed in the present study to compare the number of lesions detected. The measured CNR and SNR values were subjected to Mann-Whitney U test.Results: As a result of the 3D-FLAIR, more lesions were found as compared to 2D-FLAIR (p = 0.001). There was a greater CNRs for 3D-FLAIR images than for 2D-FLAIR images (p = 0.001). Lesions, CSF, white matter, and gray matter showed significantly higher SNRs with 3D-FLAIR (p = 0.001).Conclusion: 3D-FLAIR has exhibited greater sensitivity in detecting lesions associated with MS when contrasted with the 2D-FLAIR sequence. Significantly more lesions and higher SNRs and CNRs were detected with 3D-FLAIR in contrast to 2D-FLAIR. 3D-FLAIR may be considered the sequence of choice for MS imaging in the future.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Comparison of 3D Cube FLAIR with 2D FLAIR for Multiple Sclerosis Imaging at 3 Tesla
    Patzig, M.
    Burke, M.
    Brueckmann, H.
    Fesl, G.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2014, 186 (05): : 484 - 488
  • [2] Population-based prevalence of infarctions on 3D fluid-attenuated inversion recovery (FLAIR) imaging
    Cogswell, Petrice M.
    Aakre, Jeremiah A.
    Castillo, Anna M.
    Knopman, David S.
    Kantarci, Kejal
    Rabinstein, Alejandro A.
    Petersen, Ronald C.
    Clifford, R. Jack, Jr.
    Mielke, Michelle M.
    Vemuri, Prashanthi
    Graff-Radford, Jonathan
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2022, 31 (08):
  • [3] Fluid-attenuated inversion recovery vascular hyperintensities are not visible using 3D CUBE FLAIR sequence
    Hodel, Jerome
    Leclerc, Xavier
    Rodallec, Mathieu
    Gerber, Sophie
    Blanc, Raphael
    Outteryck, Olivier
    Benadjaoud, Samir
    Rabrait, Cecile
    Zuber, Mathieu
    Pruvo, Jean-Pierre
    Zins, Marc
    EUROPEAN RADIOLOGY, 2013, 23 (07) : 1963 - 1969
  • [4] Fluid-attenuated inversion recovery vascular hyperintensities are not visible using 3D CUBE FLAIR sequence
    Jérôme Hodel
    Xavier Leclerc
    Mathieu Rodallec
    Sophie Gerber
    Raphael Blanc
    Olivier Outteryck
    Samir Benadjaoud
    Cécile Rabrait
    Mathieu Zuber
    Jean-Pierre Pruvo
    Marc Zins
    European Radiology, 2013, 23 : 1963 - 1969
  • [5] Pitfalls of 3D FLAIR Brain Imaging: A Prospective Comparison with 2D FLAIR
    Kakeda, Shingo
    Korogi, Yukunori
    Hiai, Yasuhiro
    Ohnari, Norihiro
    Sato, Toru
    Hirai, Toshinori
    ACADEMIC RADIOLOGY, 2012, 19 (10) : 1225 - 1232
  • [6] Fluid attenuated inversion recovery (FLAIR) MRI at 7.0 Tesla: comparison with 1.5 and 3.0 Tesla
    Jaco J. M. Zwanenburg
    Jeroen Hendrikse
    Fredy Visser
    Taro Takahara
    Peter R. Luijten
    European Radiology, 2010, 20 : 915 - 922
  • [7] Fluid attenuated inversion recovery (FLAIR) MRI at 7.0 Tesla: comparison with 1.5 and 3.0 Tesla
    Zwanenburg, Jaco J. M.
    Hendrikse, Jeroen
    Visser, Fredy
    Takahara, Taro
    Luijten, Peter R.
    EUROPEAN RADIOLOGY, 2010, 20 (04) : 915 - 922
  • [8] OIL FLAIR: Optimized interleaved fluid-attenuated inversion recovery in 2D fast spin echo
    Listerud, J
    Mitchell, J
    Bagley, L
    Grossman, R
    MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (02) : 320 - 325
  • [9] 3D fluid attenuated inversion recovery (FLAIR) magnetic resonance imaging at different stages of otosclerosis
    Stefano Berrettini
    Francesco Lombardo
    Luca Bruschini
    Annalisa Ciabotti
    Canapicchi Raffaello
    Francesca De Cori Sara
    European Archives of Oto-Rhino-Laryngology, 2018, 275 : 2643 - 2652
  • [10] 3D fluid attenuated inversion recovery (FLAIR) magnetic resonance imaging at different stages of otosclerosis
    Berrettini, Stefano
    Lombardo, Francesco
    Bruschini, Luca
    Ciabotti, Annalisa
    Raffaello, Canapicchi
    Sara, De Cori
    Daniele, De Marchi
    Forli, Francesca
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2018, 275 (11) : 2643 - 2652