Comparison of T1-weighted 2D TSE, 3D SPGR, and two-point 3D Dixon MRI for automated segmentation of visceral adipose tissue at 3 Tesla

被引:17
|
作者
Fallah, Faezeh [1 ,2 ]
Machann, Juergen [2 ,3 ,4 ]
Martirosian, Petros [2 ]
Bamberg, Fabian [5 ]
Schick, Fritz [2 ]
Yang, Bin [1 ]
机构
[1] Univ Stuttgart, Inst Signal Proc & Syst Theory, Pfaffenwaldring 47, D-70569 Stuttgart, Germany
[2] Univ Clin Tubingen, Sect Expt Radiol, Dept Diagnost & Intervent Radiol, Tubingen, Germany
[3] Univ Tubingen, Inst Diabet Res & Metab Dis IDM, Helmholtz Ctr Munich, Tubingen, Germany
[4] German Ctr Diabet Res DZD, Tubingen, Germany
[5] Univ Clin Tubingen, Dept Diagnost & Intervent Radiol, Tubingen, Germany
关键词
Visceral adipose tissue; Automatic volumetry; Two-point Dixon imaging; T1-weighted imaging; 3; Tesla; FAT; QUANTIFICATION; WATER; CLASSIFICATION; ACCUMULATION; TOPOGRAPHY; SEPARATION; IDEAL; DEEP;
D O I
10.1007/s10334-016-0588-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate and compare conventional T1-weighted 2D turbo spin echo (TSE), T1-weighted 3D volumetric interpolated breath-hold examination (VIBE), and two-point 3D Dixon-VIBE sequences for automatic segmentation of visceral adipose tissue (VAT) volume at 3 Tesla by measuring and compensating for errors arising from intensity nonuniformity (INU) and partial volume effects (PVE). The body trunks of 28 volunteers with body mass index values ranging from 18 to 41.2 kg/m(2) (30.02 +/- 6.63 kg/m(2)) were scanned at 3 Tesla using three imaging techniques. Automatic methods were applied to reduce INU and PVE and to segment VAT. The automatically segmented VAT volumes obtained from all acquisitions were then statistically and objectively evaluated against the manually segmented (reference) VAT volumes. Comparing the reference volumes with the VAT volumes automatically segmented over the uncorrected images showed that INU led to an average relative volume difference of -59.22 +/- 11.59, 2.21 +/- 47.04, and -43.05 +/- 5.01 % for the TSE, VIBE, and Dixon images, respectively, while PVE led to average differences of -34.85 +/- 19.85, -15.13 +/- 11.04, and -33.79 +/- 20.38 %. After signal correction, differences of -2.72 +/- 6.60, 34.02 +/- 36.99, and -2.23 +/- 7.58 % were obtained between the reference and the automatically segmented volumes. A paired-sample two-tailed t test revealed no significant difference between the reference and automatically segmented VAT volumes of the corrected TSE (p = 0.614) and Dixon (p = 0.969) images, but showed a significant VAT overestimation using the corrected VIBE images. Under similar imaging conditions and spatial resolution, automatically segmented VAT volumes obtained from the corrected TSE and Dixon images agreed with each other and with the reference volumes. These results demonstrate the efficacy of the signal correction methods and the similar accuracy of TSE and Dixon imaging for automatic volumetry of VAT at 3 Tesla.
引用
收藏
页码:139 / 151
页数:13
相关论文
共 50 条
  • [1] Comparison of T1-weighted 2D TSE, 3D SPGR, and two-point 3D Dixon MRI for automated segmentation of visceral adipose tissue at 3 Tesla
    Faezeh Fallah
    Jürgen Machann
    Petros Martirosian
    Fabian Bamberg
    Fritz Schick
    Bin Yang
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2017, 30 : 139 - 151
  • [2] Comparison between 2D FSE T2-weighted Dixon MRI and contrast-enhanced 2D FSE and 3D FSPGR T1-weighted Dixon MRI to quantify inflammation in hands of patients with early rheumatoid arthritis
    Dion, Brice
    Lacrosse, Romain
    Michoux, Nicolas
    Stoenoiu, Maria
    Durez, Patrick
    Lecouvet, Frederic
    Kirchgesner, Thomas
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2023, 104 (7-8) : 351 - 358
  • [3] Comparison of 2D Thin Section Dixon, 3D Isotropic SPACE, and 2D T2-Weighted Sequences in Ankle MRI
    Ahn, Tae Ran
    Jeong, Yu Mi
    Jeon, Ji Young
    Park, So Hyun
    Lee, Sheen-Woo
    INVESTIGATIVE MAGNETIC RESONANCE IMAGING, 2022, 26 (04) : 284 - 293
  • [4] Fat suppression techniques for breast MRI: Dixon versus spectral fat saturation for 3D T1-weighted at 3 T
    Kalovidouri, Anastasia
    Firmenich, Natacha
    Delattre, Benedicte M. A.
    Picarra, Marlise
    Becker, Christoph D.
    Montet, Xavier
    Botsikas, Diomidis
    RADIOLOGIA MEDICA, 2017, 122 (10): : 731 - 742
  • [5] Fat suppression techniques for breast MRI: Dixon versus spectral fat saturation for 3D T1-weighted at 3 T
    Anastasia Kalovidouri
    Natacha Firmenich
    Benedicte M. A. Delattre
    Marlise Picarra
    Christoph D. Becker
    Xavier Montet
    Diomidis Botsikas
    La radiologia medica, 2017, 122 : 731 - 742
  • [6] Automated 3D MRI pancreas segmentation
    Sheng, K.
    Gou, S.
    Hu, P.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S892 - S893
  • [7] 3D T1-weighted MRI of the human knee at 1.5T
    Borthakur, A
    Regatte, RR
    Akella, SV
    Wheaton, AJ
    Kneeland, JB
    Reddy, R
    RADIOLOGY, 2002, 225 : 329 - 329
  • [8] 3D CISS, 3D MP-PAGE and 2D TSE for MRI prior to cochlear implantation.
    Seitz, J
    Held, P
    Waldeck, A
    Völk, M
    Lenhart, M
    Strotzer, M
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (03): : 227 - 231
  • [9] Review on 2D and 3D MRI Image Segmentation Techniques
    Shirly, S.
    Ramesh, K.
    CURRENT MEDICAL IMAGING REVIEWS, 2019, 15 (02) : 150 - 160
  • [10] MR imaging of articular cartilage at 1.5T and 3.0T: comparison of IDEAL 2D FSE and 3D SPGR with fat-saturated 2D FSE and 3D SPGR in a porcine model
    Cha, Jang Gyu
    Yoo, Jae Ho
    Rhee, Sun Jung
    Hwang, Seung Sik
    Han, Jong Kyu
    ACTA RADIOLOGICA, 2014, 55 (04) : 462 - 469