CRITICAL APPRAISAL OF VOLUMETRIC MODULATED ARC THERAPY IN STEREOTACTIC BODY RADIATION THERAPY FOR METASTASES TO ABDOMINAL LYMPH NODES

被引:61
|
作者
Bignardi, Mario [2 ]
Cozzi, Luca [1 ]
Fogliata, Antonella
Lattuada, Paola [2 ]
Mancosu, Pietro [2 ]
Navarria, Piera [2 ]
Urso, Gaetano [2 ]
Vigorito, Sabrina [2 ]
Scorsetti, Marta [2 ]
机构
[1] Oncol Inst So Switzerland, Dept Radiat Oncol, Med Phys Unit, CH-6504 Bellinzona, Switzerland
[2] Ist Clin Humanitas, Rozzano, Italy
关键词
RapidArc; Stereotactic body radiation therapy; IMRT; Volumetric modulated are therapy; MONTE-CARLO CALCULATIONS; CLINICAL IMPLEMENTATION; CONFORMAL RADIOTHERAPY; INTENSITY MODULATION; DOSE CALCULATION; LIVER; IMRT; CANCER; TUMORS; LUNG;
D O I
10.1016/j.ijrobp.2009.05.035
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: A planning study was performed comparing volumetric modulated arcs, RapidArc (RA), fixed beam IMRT (IM), and conformal radiotherapy (CRT) with multiple static fields or short conformal arcs in a series of patients treated with hypofractionated stereotactic body radiation therapy (SBRT) for solitary or oligo-metastases from different tumors to abdominal lymph nodes. Methods and Materials: Fourteen patients were included in the study. Dose prescription was set to 45 Gy (mean dose to clinical target volume [CTV]) in six fractions of 7.5 Gy. Objectives for CTV and planning target volume (PTV) were as follows: Dose(min) >95%, Dose(max) <107%. For organs at risk the following objectives were used: Maximum dose to spine <18 Gy; V-15Gy <35% for both kidneys, V-36Gy <1% for duodenum, V36Gy <3% for stomach and small bowel, V-15Gy <(total liver volume - 700 cm(3)) for liver. Dose-volume histograms were evaluated to assess plan quality. Results: Planning objectives on CTV and PTV were achieved by all techniques. Use of RA improved PTV coverage (V-95% = 90.2% +/- 5.2% for RA compared with 82.5% +/- 9.6% and 84.5% +/- 8.2% for CRT and IM, respectively). Most planning objectives for organs at risk were met by all techniques except for the duodenum, small bowel, and stomach, in which the CRT plans exceeded the dose/volume constraints in some patients. The MU/fraction values were as follows: 2186 +/- 211 for RA, 2583 +/- 699 for IM, and 1554 +/- 153 for CRT. Effective treatment time resulted as follows: 3.7 +/- 0.4 min for RA, 10.6 +/- 1.2 min for IM, and 6.3 +/- 0.5 min for CRT. Conclusions: Delivery of SBRT by RA showed improvements in conformal avoidance with respect to standard conformal irradiation. Delivery parameters confirmed logistical advantages of RA, particularly compared with IM. (C) 2009 Elsevier Inc.
引用
收藏
页码:1570 / 1577
页数:8
相关论文
共 50 条
  • [31] Comparing Lung Dosimetry and Secondary Malignancy Risks Associated With Stereotactic Body Radiation Therapy (SBRT) Using Intensity Modulated Radiation Therapy (IMRT), Coplanar Volumetric Modulated Arc Therapy (VMAT), and Noncoplanar Volumetric Modulated Arc Therapy Techniques
    Ng, J.
    Horowitz, D. P.
    Yan, P.
    Schweizer, M.
    Feng, W.
    Chao, K.
    Brenner, D. J.
    Hei, T. K.
    Shuryak, I.
    Cheng, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S588 - S588
  • [32] Single Arc Volumetric Modulated Arc Therapy (VMAT) for the Treatment of Prostate and Pelvic Lymph Nodes
    Wai, P.
    Sardo, A.
    Bedford, J. L.
    Warrington, A. P.
    CLINICAL ONCOLOGY, 2009, 21 (03) : 256 - 256
  • [33] Dosimetric Study of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiation Therapy (IMRT) for Stereotactic Body Radiation Therapy (SBRT) in Early Stage Lung Cancer
    Ahmad, I.
    Yah, R.
    Quinn, K.
    Seebach, A.
    Wang, H.
    MEDICAL PHYSICS, 2015, 42 (06) : 3411 - 3411
  • [34] Intrafraction Motion in Stereotactic Body Radiation Therapy for Non-Small Cell Lung Cancer: Intensity Modulated Radiation Therapy Versus Volumetric Modulated Arc Therapy
    Rossi, Maddalena M. G.
    Peulen, Heike M. U.
    Belderbos, Jose S. A.
    Sonke, Jan-Jakob
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 95 (02): : 835 - 843
  • [35] Dosimetric comparison of volumetric modulated arc therapy with robotic stereotactic radiation therapy in hepatocellular carcinoma
    Paik, Eun Kyung
    Kim, Mi-Sook
    Choi, Chul Won
    Il Jang, Won
    Lee, Sung Hyun
    Choi, Sang Hyoun
    Kim, Kum Bae
    Lee, Dong Han
    RADIATION ONCOLOGY JOURNAL, 2015, 33 (03): : 233 - 241
  • [36] Spine Stereotactic Ablative Body Radiation Therapy (SABR) With Volumetric Modulated Arc Therapy (VMAT) for Vertebral Metastases With and Without Metastatic Spinal Cord Compression (MSCC)
    Gestaut, M. M.
    Thawani, N.
    Kim, S.
    Gutti, V. R.
    Morrow, A.
    Ward, R. A.
    Huang, J. H.
    Patel, M. K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E517 - E518
  • [37] Evaluation of Fiducial Motion during Treatment of Upper Abdominal Lymph Nodes with Stereotactic Body Radiation Therapy
    Willcox, J.
    Hurwitz, M.
    Abrams, M. J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2024, 120 (02): : E497 - E497
  • [38] Feasibility of stereotactic body radiation therapy with volumetric modulated arc therapy and high intensity photon beams for hepatocellular carcinoma patients
    Wang, Po-Ming
    Hsu, Wei-Chung
    Chung, Na-Na
    Chang, Feng-Ling
    Jang, Chin-Jyh
    Fogliata, Antonella
    Scorsetti, Marta
    Cozzi, Luca
    RADIATION ONCOLOGY, 2014, 9
  • [39] Feasibility of stereotactic body radiation therapy with volumetric modulated arc therapy and high intensity photon beams for hepatocellular carcinoma patients
    Po-Ming Wang
    Wei-Chung Hsu
    Na-Na Chung
    Feng-Ling Chang
    Chin-Jyh Jang
    Antonella Fogliata
    Marta Scorsetti
    Luca Cozzi
    Radiation Oncology, 9
  • [40] Evaluation of collimator rotation for volumetric modulated arc therapy lung stereotactic body radiation therapy using flattening filter free
    Sandrini, Emmily Santos
    da Silva, Ademir Xavier
    da Silva, Claudia Menezes
    APPLIED RADIATION AND ISOTOPES, 2018, 141 : 257 - 260