CRITICAL APPRAISAL OF VOLUMETRIC MODULATED ARC THERAPY IN STEREOTACTIC BODY RADIATION THERAPY FOR METASTASES TO ABDOMINAL LYMPH NODES

被引:61
|
作者
Bignardi, Mario [2 ]
Cozzi, Luca [1 ]
Fogliata, Antonella
Lattuada, Paola [2 ]
Mancosu, Pietro [2 ]
Navarria, Piera [2 ]
Urso, Gaetano [2 ]
Vigorito, Sabrina [2 ]
Scorsetti, Marta [2 ]
机构
[1] Oncol Inst So Switzerland, Dept Radiat Oncol, Med Phys Unit, CH-6504 Bellinzona, Switzerland
[2] Ist Clin Humanitas, Rozzano, Italy
关键词
RapidArc; Stereotactic body radiation therapy; IMRT; Volumetric modulated are therapy; MONTE-CARLO CALCULATIONS; CLINICAL IMPLEMENTATION; CONFORMAL RADIOTHERAPY; INTENSITY MODULATION; DOSE CALCULATION; LIVER; IMRT; CANCER; TUMORS; LUNG;
D O I
10.1016/j.ijrobp.2009.05.035
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: A planning study was performed comparing volumetric modulated arcs, RapidArc (RA), fixed beam IMRT (IM), and conformal radiotherapy (CRT) with multiple static fields or short conformal arcs in a series of patients treated with hypofractionated stereotactic body radiation therapy (SBRT) for solitary or oligo-metastases from different tumors to abdominal lymph nodes. Methods and Materials: Fourteen patients were included in the study. Dose prescription was set to 45 Gy (mean dose to clinical target volume [CTV]) in six fractions of 7.5 Gy. Objectives for CTV and planning target volume (PTV) were as follows: Dose(min) >95%, Dose(max) <107%. For organs at risk the following objectives were used: Maximum dose to spine <18 Gy; V-15Gy <35% for both kidneys, V-36Gy <1% for duodenum, V36Gy <3% for stomach and small bowel, V-15Gy <(total liver volume - 700 cm(3)) for liver. Dose-volume histograms were evaluated to assess plan quality. Results: Planning objectives on CTV and PTV were achieved by all techniques. Use of RA improved PTV coverage (V-95% = 90.2% +/- 5.2% for RA compared with 82.5% +/- 9.6% and 84.5% +/- 8.2% for CRT and IM, respectively). Most planning objectives for organs at risk were met by all techniques except for the duodenum, small bowel, and stomach, in which the CRT plans exceeded the dose/volume constraints in some patients. The MU/fraction values were as follows: 2186 +/- 211 for RA, 2583 +/- 699 for IM, and 1554 +/- 153 for CRT. Effective treatment time resulted as follows: 3.7 +/- 0.4 min for RA, 10.6 +/- 1.2 min for IM, and 6.3 +/- 0.5 min for CRT. Conclusions: Delivery of SBRT by RA showed improvements in conformal avoidance with respect to standard conformal irradiation. Delivery parameters confirmed logistical advantages of RA, particularly compared with IM. (C) 2009 Elsevier Inc.
引用
收藏
页码:1570 / 1577
页数:8
相关论文
共 50 条
  • [1] VOLUMETRIC MODULATED ARC THERAPY IN STEREOTACTIC BODY RADIATION THERAPY FOR METASTASES TO ABDOMINAL LYMPH-NODES
    Bignardi, M.
    Cozzi, L.
    Cozzi, A. Fogliata
    Lattuada, P.
    Mancosu, P.
    Navarria, P.
    Vigorito, S.
    Urso, G.
    Scorsetti, M.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S198 - S198
  • [2] STEREOTACTIC BODY RADIATION THERAPY FOR METASTASES TO ABDOMINAL LYMPH NODES
    Bignardi, M.
    Castiglioni, S.
    Navarria, P.
    Pentimalli, S.
    Ninone, S. Agostino
    Lattuada, P.
    Urso, G.
    Scorsetti, M.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S235 - S235
  • [3] Volumetric Modulated Arc Therapy for Stereotactic Body Radiation Therapy: Initial Clinical Experience
    Matuszak, M.
    Yan, D.
    Grills, I.
    Martinez, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S723 - S724
  • [4] Critical appraisal of the role of volumetric modulated arc therapy in the radiation therapy management of breast cancer
    Cozzi, Luca
    Lohr, Frank
    Fogliata, Antonella
    Franceschini, Davide
    De Rose, Fiorenza
    Filippi, A. R.
    Guidi, Gabriele
    Vanoni, Valentina
    Scorsetti, Marta
    RADIATION ONCOLOGY, 2017, 12
  • [5] Critical appraisal of the role of volumetric modulated arc therapy in the radiation therapy management of breast cancer
    Luca Cozzi
    Frank Lohr
    Antonella Fogliata
    Davide Franceschini
    Fiorenza De Rose
    A R Filippi
    Gabriele Guidi
    Valentina Vanoni
    Marta Scorsetti
    Radiation Oncology, 12
  • [6] A comparison of robustness of volumetric modulated arc therapy and dynamic conformal arc therapy for lung stereotactic body radiation therapy
    Teague, Kathlina M.
    Miller, Daniel C.
    Nyamwanda, Jacqueline A.
    Prichard, Hugh A.
    Kirk, Michael C.
    MEDICAL DOSIMETRY, 2022, 47 (01) : 110 - 110
  • [7] Volumetric Modulated Arc Therapy (VMAT) Treatment Planning for Thoracic Vertebral Metastases Using Stereotactic Body Radiation Therapy (SBRT)
    Mallory, M.
    Pokhrel, D.
    Badkul, R. K.
    Jiang, H.
    Wang, F.
    Lominska, C. E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E650 - E651
  • [8] Fractionated Stereotactic Radiation Therapy Using Volumetric Modulated Arc Therapy in Patients with Solitary Brain Metastases
    Zhou, Chong
    Xia, Youyou
    Huang, Pei
    Guan, Luan
    Shen, Xiaoming
    Hao, Dawei
    Chen, Meng
    Ren, Hongrong
    Lian, Lian
    Yin, Haitao
    BIOMED RESEARCH INTERNATIONAL, 2020, 2020
  • [9] Role of Stereotactic Body Radiation Therapy With Volumetric Modulated Arc Therapy Technique and FFF Beams for Abdomino-Pelvic Lymph Node Metastases in Oligometastatic Patients
    Franzese, C.
    Cozzi, L.
    Clerici, E.
    D'Agostino, G. R.
    Navarria, P.
    Comito, T.
    De Rose, F.
    Ascolese, A. M.
    Franceschini, D.
    Mancosu, P.
    Tomatis, S.
    Scorsetti, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E142 - E143
  • [10] Stereotactic Body Radiation Therapy and Immunotherapy in Abdominal and Pelvic Lymph Node Metastases
    Katipally, R. R.
    Korpics, M. C.
    Partouche, J.
    Cutright, D.
    Pointer, K. B.
    Bestvina, C. M.
    Luke, J. J.
    Pitroda, S. P.
    Chmura, S. J.
    Juloori, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 111 (03): : S58 - S58