Improved whole-brain SNR with an integrated high-permittivity material in a head array at 7T

被引:25
|
作者
Lakshmanan, Karthik [1 ,2 ]
Carluccio, Giuseppe [1 ,2 ]
Walczyk, Jerzy [1 ,2 ]
Brown, Ryan [1 ,2 ,3 ]
Rupprecht, Sebastian [4 ]
Yang, Qing X. [4 ]
Lanagan, Michael T. [4 ]
Collins, Christopher M. [1 ,2 ,3 ]
机构
[1] NYU, Sch Med, Dept Radiol, Bernard & Irene Schwartz Ctr Biomed Imaging, 660 First Ave,Fourth Floor, New York, NY 10016 USA
[2] New York Univ, Sch Med, Ctr Adv Imaging Innovat & Res CAI2R, Dept Radiol, New York, NY 10016 USA
[3] Sackler Inst Grad Biomed Sci, New York, NY USA
[4] HyQRS, State Coll, PA USA
基金
美国国家卫生研究院;
关键词
coil; efficiency; MRI; permittivity; SNR; COIL; SENSITIVITY; DESIGN; PADS; MRI;
D O I
10.1002/mrm.28780
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To demonstrate that strategic use of materials with high electric permittivity along with integrated head-sized coil arrays can improve SNR in the entire brain. Methods: Numerical simulations were used to design a high-permittivity material (HPM) helmet for enhancing SNR throughout the brain in receive arrays of 8 and 28 channels. Then, two 30-channel head coils of identical geometry were constructed: one fitted with a prototype helmet-shaped ceramic HPM helmet, and the second with a helmet-shaped low-permittivity shell, each 8-mm thick. An eight-channel dipole array was used for excitation. In vivo maps of excitation flip angle and SNR were acquired. Results: Simulation results showed improvement in transmit efficiency by up to 65% and in receive-side SNR by up to 47% on average through the head with use of an HPM helmet. Experimental results showed that experimental transmit efficiency was improved by approximately 56% at the center of brain, and experimental receive-side SNR (SNR normalized to flip angle) was improved by approximately 21% on average through orthogonal planes through the cerebrum, including at the center of the brain, with the HPM. Conclusion: Although HPM is used increasingly to improve transmit efficiency locally in situations in which the transmit coil and imaging volume are much larger than the HPM, here we demonstrate that HPM can also be used to improve transmit efficiency and receive-side SNR throughout the brain by improving performance of a head-sized receive array. This includes the center of the brain, where it is difficult to improve SNR by other means.
引用
收藏
页码:1167 / 1174
页数:8
相关论文
共 43 条
  • [1] Improved brain imaging with a head array with integrated high-permittivity material
    Lakshmanan, Karthik
    Walczyk, Jerzy
    Brown, Ryan
    Rupprecht, Sebastian
    Yang, Qing X.
    Lanagan, Michael T.
    Collins, Christopher
    5TH INTERNATIONAL CONFERENCE ON METAMATERIALS AND NANOPHOTONICS (METANANO 2020), 2020, 2300
  • [2] Large improvement in RF magnetic fields and imaging SNR with whole-head high-permittivity slurry helmet for human-brain MRI applications at 7T
    Soon, Soo Han
    Li, Xin
    Waks, Matt
    Zhu, Xiao-Hong
    Wiesner, Hannes M.
    Gandji, Navid P.
    Yang, Qing X.
    Lanagan, Michael T.
    Chen, Wei
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (03) : 1205 - 1219
  • [3] High-permittivity pads to enhance SNR and transmit efficiency in MRI of the heart at 7T: a simulation study
    Carluccio, Giuseppe
    Collins, Christopher M.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2022, 35 (06) : 903 - 909
  • [4] High-permittivity pads to enhance SNR and transmit efficiency in MRI of the heart at 7T: a simulation study
    Giuseppe Carluccio
    Christopher M. Collins
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2022, 35 : 903 - 909
  • [5] Large improvement in RF magnetic fields and imaging SNR with whole-head high-permittivity slurry helmet for human-brain MRI applications at 7 T
    Soon, Soo Han
    Li, Xin
    Waks, Matt
    Zhu, Xiao-Hong
    Wiesner, Hannes M.
    Gandji, Navid P.
    Yang, Qing X.
    Lanagan, Michael T.
    Chen, Wei
    MAGNETIC RESONANCE IN MEDICINE, 2024,
  • [6] High-permittivity pad design tool for 7T neuroimaging and 3T body imaging
    van Gemert, Jeroen
    Brink, Wyger
    Webb, Andrew
    Remis, Rob
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (05) : 3370 - 3378
  • [7] A 16-channel AC/DC array coil for anesthetized monkey whole-brain imaging at 7T
    Gao, Yang
    Mareyam, Azma
    Sun, Yi
    Witzel, Thomas
    Arango, Nicolas
    Kuang, Irene
    White, Jacob
    Roe, Anna Wang
    Wald, Lawrence
    Stockmann, Jason
    Zhang, Xiaotong
    NEUROIMAGE, 2020, 207
  • [8] High-resolution whole-brain diffusion MRI at 7T using radiofrequency parallel transmission
    Wu, Xiaoping
    Auerbach, Edward J.
    Vu, An T.
    Moeller, Steen
    Lenglet, Christophe
    Schmitter, Sebastian
    Van de Moortele, Pierre-Francois
    Yacoub, Essa
    Ugurbil, Kamil
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (05) : 1857 - 1870
  • [9] An integrated RF-receive/B0-shim array coil boosts performance of whole-brain MR spectroscopic imaging at 7T
    Esmaeili, Morteza
    Stockmann, Jason
    Strasser, Bernhard
    Arango, Nicolas
    Thapa, Bijaya
    Wang, Zhe
    van der Kouwe, Andre
    Dietrich, Jorg
    Cahill, Daniel P.
    Batchelor, Tracy T.
    White, Jacob
    Adalsteinsson, Elfar
    Wald, Lawrence
    Andronesi, Ovidiu C.
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [10] Whole-brain 3D FLAIR at 7T using direct signal control
    Beqiri, Arian
    Hoogduin, Hans
    Sbrizzi, Alessandro
    Hajnal, Joseph V.
    Malik, Shaihan J.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (04) : 1533 - 1545