Improved whole-brain SNR with an integrated high-permittivity material in a head array at 7T

被引:25
|
作者
Lakshmanan, Karthik [1 ,2 ]
Carluccio, Giuseppe [1 ,2 ]
Walczyk, Jerzy [1 ,2 ]
Brown, Ryan [1 ,2 ,3 ]
Rupprecht, Sebastian [4 ]
Yang, Qing X. [4 ]
Lanagan, Michael T. [4 ]
Collins, Christopher M. [1 ,2 ,3 ]
机构
[1] NYU, Sch Med, Dept Radiol, Bernard & Irene Schwartz Ctr Biomed Imaging, 660 First Ave,Fourth Floor, New York, NY 10016 USA
[2] New York Univ, Sch Med, Ctr Adv Imaging Innovat & Res CAI2R, Dept Radiol, New York, NY 10016 USA
[3] Sackler Inst Grad Biomed Sci, New York, NY USA
[4] HyQRS, State Coll, PA USA
基金
美国国家卫生研究院;
关键词
coil; efficiency; MRI; permittivity; SNR; COIL; SENSITIVITY; DESIGN; PADS; MRI;
D O I
10.1002/mrm.28780
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To demonstrate that strategic use of materials with high electric permittivity along with integrated head-sized coil arrays can improve SNR in the entire brain. Methods: Numerical simulations were used to design a high-permittivity material (HPM) helmet for enhancing SNR throughout the brain in receive arrays of 8 and 28 channels. Then, two 30-channel head coils of identical geometry were constructed: one fitted with a prototype helmet-shaped ceramic HPM helmet, and the second with a helmet-shaped low-permittivity shell, each 8-mm thick. An eight-channel dipole array was used for excitation. In vivo maps of excitation flip angle and SNR were acquired. Results: Simulation results showed improvement in transmit efficiency by up to 65% and in receive-side SNR by up to 47% on average through the head with use of an HPM helmet. Experimental results showed that experimental transmit efficiency was improved by approximately 56% at the center of brain, and experimental receive-side SNR (SNR normalized to flip angle) was improved by approximately 21% on average through orthogonal planes through the cerebrum, including at the center of the brain, with the HPM. Conclusion: Although HPM is used increasingly to improve transmit efficiency locally in situations in which the transmit coil and imaging volume are much larger than the HPM, here we demonstrate that HPM can also be used to improve transmit efficiency and receive-side SNR throughout the brain by improving performance of a head-sized receive array. This includes the center of the brain, where it is difficult to improve SNR by other means.
引用
收藏
页码:1167 / 1174
页数:8
相关论文
共 43 条
  • [41] Whole-Brain Amide Proton Transfer (APT) and Nuclear Overhauser Enhancement (NOE) Imaging in Glioma Patients Using Low-Power Steady-State Pulsed Chemical Exchange Saturation Transfer (CEST) Imaging at 7T
    Heo, Hye-Young
    Jones, Craig K.
    Hua, Jun
    Yadav, Nirbhay
    Agarwal, Shruti
    Zhou, Jinyuan
    van Zijl, Peter C. M.
    Pillai, Jay J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (01) : 41 - 50
  • [42] High resolution automated labeling of the hippocampus and amygdala using a 3D convolutional neural network trained on whole brain 700 μm isotropic 7T MP2RAGE MRI
    Pardoe, Heath R.
    Antony, Arun Raj
    Hetherington, Hoby
    Bagic, Anto I.
    Shepherd, Timothy M.
    Friedman, Daniel
    Devinsky, Orrin
    Pan, Jullie
    HUMAN BRAIN MAPPING, 2021, 42 (07) : 2089 - 2098
  • [43] Improved Blood Suppression of Motion-Sensitized Driven Equilibrium in High-Resolution Whole-Brain Vessel Wall Imaging: Comparison of Contrast-Enhanced 3D T1-Weighted FSE with Motion-Sensitized Driven Equilibrium and Delay Alternating with Nutation for Tailored Excitation
    Kim, D. J.
    Lee, H. -j.
    Baik, J.
    Hwang, M. J.
    Miyoshi, M.
    Kang, Y.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2022, 43 (12) : 1713 - 1718