Improved whole-brain SNR with an integrated high-permittivity material in a head array at 7T

被引:25
|
作者
Lakshmanan, Karthik [1 ,2 ]
Carluccio, Giuseppe [1 ,2 ]
Walczyk, Jerzy [1 ,2 ]
Brown, Ryan [1 ,2 ,3 ]
Rupprecht, Sebastian [4 ]
Yang, Qing X. [4 ]
Lanagan, Michael T. [4 ]
Collins, Christopher M. [1 ,2 ,3 ]
机构
[1] NYU, Sch Med, Dept Radiol, Bernard & Irene Schwartz Ctr Biomed Imaging, 660 First Ave,Fourth Floor, New York, NY 10016 USA
[2] New York Univ, Sch Med, Ctr Adv Imaging Innovat & Res CAI2R, Dept Radiol, New York, NY 10016 USA
[3] Sackler Inst Grad Biomed Sci, New York, NY USA
[4] HyQRS, State Coll, PA USA
基金
美国国家卫生研究院;
关键词
coil; efficiency; MRI; permittivity; SNR; COIL; SENSITIVITY; DESIGN; PADS; MRI;
D O I
10.1002/mrm.28780
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To demonstrate that strategic use of materials with high electric permittivity along with integrated head-sized coil arrays can improve SNR in the entire brain. Methods: Numerical simulations were used to design a high-permittivity material (HPM) helmet for enhancing SNR throughout the brain in receive arrays of 8 and 28 channels. Then, two 30-channel head coils of identical geometry were constructed: one fitted with a prototype helmet-shaped ceramic HPM helmet, and the second with a helmet-shaped low-permittivity shell, each 8-mm thick. An eight-channel dipole array was used for excitation. In vivo maps of excitation flip angle and SNR were acquired. Results: Simulation results showed improvement in transmit efficiency by up to 65% and in receive-side SNR by up to 47% on average through the head with use of an HPM helmet. Experimental results showed that experimental transmit efficiency was improved by approximately 56% at the center of brain, and experimental receive-side SNR (SNR normalized to flip angle) was improved by approximately 21% on average through orthogonal planes through the cerebrum, including at the center of the brain, with the HPM. Conclusion: Although HPM is used increasingly to improve transmit efficiency locally in situations in which the transmit coil and imaging volume are much larger than the HPM, here we demonstrate that HPM can also be used to improve transmit efficiency and receive-side SNR throughout the brain by improving performance of a head-sized receive array. This includes the center of the brain, where it is difficult to improve SNR by other means.
引用
收藏
页码:1167 / 1174
页数:8
相关论文
共 43 条
  • [31] Calibration-free whole-brain CEST imaging at 7T with parallel transmit pulse design for saturation homogeneity utilizing universal pulses (PUSHUP)
    Voelzke, Yannik
    Akbey, Suzan
    Loewen, Daniel
    Pracht, Eberhard Daniel
    Stirnberg, Ruediger
    Gras, Vincent
    Boulant, Nicolas
    Zaiss, Moritz
    Stoecker, Tony
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (02) : 630 - 642
  • [32] Deconstructing the self and reshaping perceptions: An intensive whole-brain 7T MRI case study of the stages of insight during advanced investigative insight meditation
    Yang, Winson F. Z.
    Chowdhury, Avijit
    Sparby, Terje
    Sacchet, Matthew D.
    NEUROIMAGE, 2025, 305
  • [33] Calibration-free whole-brain CEST imaging at 7T with parallel transmit pulse design for saturation homogeneity utilizing universal pulses (PUSHUP)
    Voelzke, Yannik
    Akbey, Suzan
    Loewen, Daniel
    Pracht, Eberhard Daniel
    Stirnberg, Ruediger
    Gras, Vincent
    Boulant, Nicolas
    Zaiss, Moritz
    Stoecker, Tony
    MAGNETIC RESONANCE IN MEDICINE, 2024, : 630 - 642
  • [34] An improved PSF mapping method for EPI distortion correction in human brain at ultra high field (7T)
    Chung, Jun-Young
    In, Myung-Ho
    Oh, Se-Hong
    Zaitsev, Maxim
    Speck, Oliver
    Cho, Zang-Hee
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2011, 24 (03) : 179 - 190
  • [35] An improved PSF mapping method for EPI distortion correction in human brain at ultra high field (7T)
    Jun-Young Chung
    Myung-Ho In
    Se-Hong Oh
    Maxim Zaitsev
    Oliver Speck
    Zang-Hee Cho
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2011, 24 : 179 - 190
  • [36] An 8/15-channel Tx/Rx head neck RF coil combination with region-specific B1+ shimming for whole-brain MRI focused on the cerebellum at 7T
    Pfaffenrot, Viktor
    Brunheim, Sascha
    Rietsch, Stefan H. G.
    Koopmans, Peter J.
    Ernst, Thomas M.
    Kraff, Oliver
    Orzada, Stephan
    Quick, Harald H.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (03) : 1252 - 1265
  • [37] A 31-channel integrated "AC/DC" B0 shim and radiofrequency receive array coil for improved 7T MRI
    Stockmann, Jason P.
    Arango, Nicolas S.
    Witzel, Thomas
    Mareyam, Azma
    Sappo, Charlotte
    Zhou, Jiazheng
    Jenkins, Lucas
    Craven-Brightman, Lincoln
    Milshteyn, Eugene
    Davids, Mathias
    Hoge, W. Scott
    Sliwiak, Monika
    Nasr, Shahin
    Keil, Boris
    Adalsteinsson, Elfar
    Guerin, Bastien
    White, Jacob K.
    Setsompop, Kawin
    Polimeni, Jonathan R.
    Wald, Lawrence L.
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (02) : 1074 - 1092
  • [38] Double-row 18-loop transceive 32-loop receive tight-fit array provides for whole-brain coverage, high transmit performance, and SNR improvement near the brain center at 9.4T
    Avdievich, Nikolai I.
    Giapitzakis, Ioannis-Angelos
    Bause, Jonas
    Shajan, Gunamony
    Scheffler, Klaus
    Henning, Anke
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (05) : 3392 - 3405
  • [39] Reconstruction for 7T high-resolution whole-brain diffusion MRI using two-stage N/2 ghost correction and L1-SPIRiT without single-band reference
    Pan, Ziyi
    Ma, Xiaodong
    Dai, Erpeng
    Auerbach, Edward J.
    Guo, Hua
    Ugurbil, Kamil
    Wu, Xiaoping
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (05) : 1915 - 1930
  • [40] Quantitative 7T sodium magnetic resonance imaging of the human brain using a 32-channel phased-array head coil: Application to patients with secondary progressive multiple sclerosis
    Wilferth, Tobias
    Mennecke, Angelika
    Gast, Lena, V
    Lachner, Sebastian
    Mueller, Max
    Rothhammer, Veit
    Huhn, Konstantin
    Uder, Michael
    Doerfler, Arnd
    Nagel, Armin M.
    Schmidt, Manuel
    NMR IN BIOMEDICINE, 2022, 35 (12)