Uncertainty of antioxidant profiling in complex mixtures using liquid chromatography involving post-column derivatisation

被引:1
|
作者
Glod, Bronislaw K. [1 ]
Kaminski, Marian [2 ]
Zarzycki, Pawel K. [3 ]
机构
[1] Siedlce Univ Nat Sci & Humanities, Fac Sci, Dept Analyt Chem, Inst Chem, PL-08110 Siedlce, Poland
[2] Gdansk Univ Technol, Fac Chem, Dept Chem & Proc Engn, PL-80233 Gdansk, Poland
[3] Koszalin Univ Technol, Dept Civil & Environm Engn, Sect Toxicol & Bioanalyt, PL-75453 Koszalin, Poland
关键词
Total antioxidant activity; Antioxidant fingerprints; Trolox equivalent antioxidant capacity; Post-column derivatisation; HPLC; Temperature; Food analysis; Food composition; Analytical method uncertainty; FLAVONOIDS;
D O I
10.1016/j.jfca.2013.02.012
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The main goal of this paper is to discuss the problems associated with antioxidant profiling in complex samples using a high-throughput HPLC system coupled with post-column derivatisation reactor. Based on the experimental data reported in the literature, we demonstrated that improper optimisation of temperature and/or pH assay conditions performed using an on-line derivatisation reactor may substantially change the antioxidant peaks ratio of targeted phytochemical compounds. It has been found that despite the relatively high stability of flavonoids at high temperature and under binary mobile phase HPLC conditions, the reaction of target compounds with common ABTS, FCR and DPPH radicals at elevated regions (particularly above 100 degrees C) dramatically changes their antioxidant activity values expressed, for example, as TEAC (Trolox equivalent antioxidant capacity) parameters. In principle, separation and detection processes of antioxidant profiling assay must not significantly affect the antioxidant activity of target compounds. In the case of foods eaten by humans or animals, critical experimental parameters such as pH and temperature concerning interaction of target analytes with derivatisation reagent should be as close as possible to the real physiological values. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:216 / 219
页数:4
相关论文
共 50 条
  • [41] Determination of organothiophosphorus pesticides in water by liquid chromatography and post-column chemiluminescence with cerium(IV)
    Catala-Icardo, Monica
    Lahuerta-Zamora, Luis
    Torres-Cartas, Sagrario
    Meseguer-Lloret, Susana
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1341 : 31 - 40
  • [42] URINARY METANEPHRINES AS MEASURED BY LIQUID-CHROMATOGRAPHY WITH AN ONLINE POST-COLUMN REACTION DETECTOR
    FLOOD, JG
    MCCOMB, RB
    CLINICAL CHEMISTRY, 1981, 27 (07) : 1268 - 1271
  • [43] NEW ASPECTS OF POST-COLUMN DERIVATIZATION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    FREI, RW
    MICHEL, L
    SANTI, W
    JOURNAL OF CHROMATOGRAPHY, 1977, 142 (NOV): : 261 - 270
  • [44] DETERMINATION OF ALKANOLAMINES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH POST-COLUMN DERIVATIZATION
    NAKAE, A
    MANSHO, K
    TSUJI, K
    BUNSEKI KAGAKU, 1981, 30 (06) : 353 - 357
  • [45] DETERMINATION OF HISTAMINE IN FISH BY LIQUID-CHROMATOGRAPHY WITH POST-COLUMN REACTION AND FLUOROMETRIC DETECTION
    WALTERS, MJ
    JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1984, 67 (06): : 1040 - 1043
  • [46] Determination of carbosulfan in oranges by high-performance liquid chromatography with post-column fluorescence
    FMC Corp.,Agric.Chem.Gp, Princeton, NJ 08543, United States
    Analyst, 120 (10): : 2479 - 2481
  • [47] DESIGN AND APPLICATION OF A POST-COLUMN EXTRACTION SYSTEM COMPATIBLE WITH MINIATURIZED LIQUID-CHROMATOGRAPHY
    APFFEL, JA
    BRINKMAN, UAT
    FREI, RW
    CHROMATOGRAPHIA, 1984, 18 (01) : 5 - 10
  • [48] Recent advances in post-column derivatization: Enhancing sensitivity and selectivity in liquid chromatography analysis
    Shi, Endao
    Zuo, Lihua
    Yao, Huan
    Sun, Zhi
    Chen, Di
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2024, 177
  • [49] AN UPDATE ON POST-COLUMN DERIVATIZATION METHODOLOGY IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    STEWART, JT
    BACHMAN, WJ
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1988, 7 (03) : 106 - 111
  • [50] Analysis of oligosaccharides in a honey by high performance liquid chromatography with a post-column reaction system
    Mishima, S
    Hiraiwa, N
    Araki, Y
    JOURNAL OF THE JAPANESE SOCIETY FOR FOOD SCIENCE AND TECHNOLOGY-NIPPON SHOKUHIN KAGAKU KOGAKU KAISHI, 2003, 50 (02): : 78 - 84