Uncertainty of antioxidant profiling in complex mixtures using liquid chromatography involving post-column derivatisation

被引:1
|
作者
Glod, Bronislaw K. [1 ]
Kaminski, Marian [2 ]
Zarzycki, Pawel K. [3 ]
机构
[1] Siedlce Univ Nat Sci & Humanities, Fac Sci, Dept Analyt Chem, Inst Chem, PL-08110 Siedlce, Poland
[2] Gdansk Univ Technol, Fac Chem, Dept Chem & Proc Engn, PL-80233 Gdansk, Poland
[3] Koszalin Univ Technol, Dept Civil & Environm Engn, Sect Toxicol & Bioanalyt, PL-75453 Koszalin, Poland
关键词
Total antioxidant activity; Antioxidant fingerprints; Trolox equivalent antioxidant capacity; Post-column derivatisation; HPLC; Temperature; Food analysis; Food composition; Analytical method uncertainty; FLAVONOIDS;
D O I
10.1016/j.jfca.2013.02.012
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The main goal of this paper is to discuss the problems associated with antioxidant profiling in complex samples using a high-throughput HPLC system coupled with post-column derivatisation reactor. Based on the experimental data reported in the literature, we demonstrated that improper optimisation of temperature and/or pH assay conditions performed using an on-line derivatisation reactor may substantially change the antioxidant peaks ratio of targeted phytochemical compounds. It has been found that despite the relatively high stability of flavonoids at high temperature and under binary mobile phase HPLC conditions, the reaction of target compounds with common ABTS, FCR and DPPH radicals at elevated regions (particularly above 100 degrees C) dramatically changes their antioxidant activity values expressed, for example, as TEAC (Trolox equivalent antioxidant capacity) parameters. In principle, separation and detection processes of antioxidant profiling assay must not significantly affect the antioxidant activity of target compounds. In the case of foods eaten by humans or animals, critical experimental parameters such as pH and temperature concerning interaction of target analytes with derivatisation reagent should be as close as possible to the real physiological values. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:216 / 219
页数:4
相关论文
共 50 条
  • [31] Measurement of bromate in bread by liquid chromatography with post-column flow reactor detection
    Himata, K
    Noda, M
    Ando, S
    Yamada, Y
    JOURNAL OF AOAC INTERNATIONAL, 2000, 83 (02) : 347 - 355
  • [32] Fluorimetric determination of pantothenic acid in foods by liquid chromatography with post-column derivatization
    Pakin, C
    Bergaentzlé, M
    Hubscher, V
    Aoudé-Werner, D
    Hasselmann, C
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1035 (01) : 87 - 95
  • [33] DERIVATIZATION AND POST-COLUMN REACTIONS FOR IMPROVED DETECTION IN LIQUID-CHROMATOGRAPHY ELECTROCHEMISTRY
    KRULL, IS
    SELAVKA, CM
    DUDA, C
    JACOBS, W
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1985, 8 (15): : 2845 - 2870
  • [34] Quantification of PSP toxins in toxic shellfish matrices using post column oxidation liquid chromatography and pre-column oxidation liquid chromatography methods suggests post-column oxidation liquid chromatography as a good monitoring method of choice
    Rey, Veroica
    Botana, Ana M.
    Botana, Luis M.
    TOXICON, 2017, 129 : 28 - 35
  • [35] Quantitative profiling of proteins in complex mixtures using liquid chromatography and mass spectrometry
    Chelius, D
    Bondarenko, PV
    JOURNAL OF PROTEOME RESEARCH, 2002, 1 (04) : 317 - 323
  • [36] Determination of tetracycline antibiotics in salmon muscle by liquid chromatography using post-column derivatization with fluorescence detection
    Pena, AL
    Lino, CM
    Silveira, MIN
    JOURNAL OF AOAC INTERNATIONAL, 2003, 86 (05) : 925 - 929
  • [37] POST-COLUMN DERIVATIZATION OF GUANIDINO COMPOUNDS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING NINHYDRIN
    HIRAGA, Y
    KINOSHITA, T
    JOURNAL OF CHROMATOGRAPHY, 1981, 226 (01): : 43 - 51
  • [38] Fluorescence Bioanalysis of Bevacizumab Using Pre-Column and Post-Column Derivatization - Liquid Chromatography After Immunoaffinity Magnetic Purification
    Todoroki, Kenichiro
    Nakano, Tatsuki
    Hayashi, Hideki
    Mizuno, Hajime
    Min, Jun Zhe
    Toyo'oka, Toshimasa
    CHROMATOGRAPHY, 2020, 41 (03) : 115 - 122
  • [39] On-line on-chip post-column derivatisation reactions for pre-ionisation of analytes and cluster analysis in gradient μ-liquid chromatography/electrospray mass spectrometry
    Spikmans, V
    Lane, SJ
    Leavens, B
    Manz, A
    Smith, NW
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (14) : 1377 - 1388
  • [40] Determination of Hexavalent Chromium in Leather by Ion-exchange Chromatography. Direct Method versus Post-column Derivatisation Method
    Compte, Irene
    Cuadros, Rosa
    Bacardit, Anna
    Combalia, Felip
    Font, Joaquim
    JOURNAL OF THE SOCIETY OF LEATHER TECHNOLOGISTS AND CHEMISTS, 2021, 105 (04): : 175 - 182