Uncertainty of antioxidant profiling in complex mixtures using liquid chromatography involving post-column derivatisation

被引:1
|
作者
Glod, Bronislaw K. [1 ]
Kaminski, Marian [2 ]
Zarzycki, Pawel K. [3 ]
机构
[1] Siedlce Univ Nat Sci & Humanities, Fac Sci, Dept Analyt Chem, Inst Chem, PL-08110 Siedlce, Poland
[2] Gdansk Univ Technol, Fac Chem, Dept Chem & Proc Engn, PL-80233 Gdansk, Poland
[3] Koszalin Univ Technol, Dept Civil & Environm Engn, Sect Toxicol & Bioanalyt, PL-75453 Koszalin, Poland
关键词
Total antioxidant activity; Antioxidant fingerprints; Trolox equivalent antioxidant capacity; Post-column derivatisation; HPLC; Temperature; Food analysis; Food composition; Analytical method uncertainty; FLAVONOIDS;
D O I
10.1016/j.jfca.2013.02.012
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The main goal of this paper is to discuss the problems associated with antioxidant profiling in complex samples using a high-throughput HPLC system coupled with post-column derivatisation reactor. Based on the experimental data reported in the literature, we demonstrated that improper optimisation of temperature and/or pH assay conditions performed using an on-line derivatisation reactor may substantially change the antioxidant peaks ratio of targeted phytochemical compounds. It has been found that despite the relatively high stability of flavonoids at high temperature and under binary mobile phase HPLC conditions, the reaction of target compounds with common ABTS, FCR and DPPH radicals at elevated regions (particularly above 100 degrees C) dramatically changes their antioxidant activity values expressed, for example, as TEAC (Trolox equivalent antioxidant capacity) parameters. In principle, separation and detection processes of antioxidant profiling assay must not significantly affect the antioxidant activity of target compounds. In the case of foods eaten by humans or animals, critical experimental parameters such as pH and temperature concerning interaction of target analytes with derivatisation reagent should be as close as possible to the real physiological values. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:216 / 219
页数:4
相关论文
共 50 条
  • [21] Immunoaffinity column cleanup with liquid chromatography using post-column bromination for aflatoxins in medicinal herbs and plant extracts
    Zhang, XH
    Liu, HL
    Chen, JM
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2005, 43 (01) : 47 - 51
  • [22] High-performance liquid chromatography with post-column derivatisation and fluorescence detection for sensitive determination of aflatoxin M1 in milk and cheese
    Manetta, AC
    Di Giuseppe, L
    Giammarco, M
    Fusaro, I
    Simonella, A
    Gramenzi, A
    Formigoni, A
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1083 (1-2) : 219 - 222
  • [23] LIQUID-CHROMATOGRAPHY OF DEMOXEPAM AND PHENOTHIAZINES USING A POST-COLUMN PHOTOCHEMICAL REACTOR AND FLUORESCENCE DETECTION
    BRINKMAN, UAT
    WELLING, PLM
    DEVRIES, G
    SCHOLTEN, AHMT
    FREI, RW
    JOURNAL OF CHROMATOGRAPHY, 1981, 217 (NOV): : 463 - 471
  • [24] Fluorescence detection of biotin using post-column derivatization with OPA in high performance liquid chromatography
    Nojiri, S
    Kamata, K
    Nishijima, M
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 16 (08) : 1357 - 1362
  • [25] BIOANALYSIS OF DRUGS AND METABOLITES BY LIQUID-CHROMATOGRAPHY USING COUPLED COLUMNS OR POST-COLUMN DERIVATIZATION
    JOHANSSON, M
    ACTA PHARMACEUTICA SUECICA, 1988, 25 (06): : 330 - 331
  • [26] Determination of gentamicin in bovine milk using liquid chromatography with post-column derivatization and fluorescence detection
    Kijak, PJ
    Jackson, J
    Shaikh, B
    JOURNAL OF CHROMATOGRAPHY B, 1997, 691 (02): : 377 - 382
  • [27] IN-COLUMN AND POST-COLUMN PHOTOCHEMICAL FLUORESCENCE ENHANCEMENT IN PACKED CAPILLARY LIQUID-CHROMATOGRAPHY
    JANSEN, H
    VREULS, JJ
    VANDERHEIDE, TAJ
    DEJONG, GJ
    BRINKMAN, UAT
    FREI, RW
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1988, 11 (9-10): : 1855 - 1863
  • [28] Immunoaffinity column cleanup with liquid chromatography using post-column bromination for determination of aflatoxins in hazelnut paste: Interlaboratory study
    Senyuva, HZ
    Gilbert, J
    JOURNAL OF AOAC INTERNATIONAL, 2005, 88 (02) : 526 - 535
  • [29] ONLINE POST-COLUMN EXTRACTION IN COLUMN LIQUID-CHROMATOGRAPHY WITH ELECTRON-CAPTURE DETECTION
    MARIS, FA
    NIJENHUIS, M
    FREI, RW
    DEJONG, GJ
    BRINKMAN, UAT
    JOURNAL OF CHROMATOGRAPHY, 1988, 435 (02): : 297 - 306
  • [30] Immunoaffinity column cleanup with liquid chromatography using post-column bromination for determination of aflatoxins in hazelnut paste: Interlaboratory study
    Senyuva, Hamide Z.
    Gilbert, John
    Arasiler, Z.
    Ayabakan, A.
    Burdaspal, P.
    Carter, J.
    De Rechter, P.
    Driffield, M.
    Gallagher, M.
    Kroger, K.
    Özer, H.
    Özkaya, Ş.
    Patel, S.
    Trucksess, M.
    Van Egmond, H.
    Yilmaz, A.
    Journal of AOAC International, 1600, 88 (02): : 526 - 535