Bolus timing in high-pitch CT angiography of the aorta

被引:14
|
作者
Beeres, Martin [1 ]
Loch, Matthias [1 ]
Schulz, Boris [1 ]
Kerl, Matthias [1 ]
Al-Butmeh, Firas [1 ]
Bodelle, Boris [1 ]
Herrmann, Eva [2 ]
Gruber-Rouh, Tatjana [1 ]
Lee, Clara [1 ]
Jacobi, Volkmar [1 ]
Vogl, Thomas J. [1 ]
Bauer, Ralf W. [1 ]
机构
[1] Clin Goethe Univ, Dept Diagnost & Intervent Radiol, D-60590 Frankfurt, Germany
[2] Clin Goethe Univ, Dept Biostat, D-60590 Frankfurt, Germany
关键词
CT angiography; Aorta; High-pitch CT; Dual-source CT; Bolus geometry; IMAGE QUALITY; INJECTION; PROTOCOLS;
D O I
10.1016/j.ejrad.2013.01.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To investigate the bolus geometry in high-pitch CT angiography (CTA) of the aorta without ECG synchronisation in comparison to single-source CT. Methods: Overall 160 consecutive patients underwent CTA either in conventional single-source mode with a pitch of 1.2 (group 1), or in dual-source mode with a pitch of 3.0 (groups 2, 3 and 4) using different contrast media timings with bolus triggering at 140HU (5 s, group 1; 10 s, group 2; 12 s, group 3; 14 s, group 4). Contrast material, saline flush, flow rate and kV/mAs settings were kept equal for optimum comparability. Aortic attenuation was measured along the z-axis of the patient at different anatomic landmarks and subjective image quality was compared. Results: The most homogeneous enhancement of the aorta was reached with a delay of 10 s after reaching the trigger threshold. The imaging length was not significantly different, but the examination time was significantly (p < 0.001) shorter in the high-pitch group (7.7 s vs. 1.7 s for group 1 vs. 2, 3 and 4). Conclusion: In high-pitch CT angiography using a start delay of 10 s after a trigger threshold of 140HU in the descending aorta is reached, a homogenous contrast along the z-axis is accomplished. (C) 2013 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1028 / 1033
页数:6
相关论文
共 50 条
  • [41] Performance of turbo high-pitch dual-source CT for coronary CT angiography: first ex vivo and patient experience
    Morsbach, Fabian
    Gordic, Sonja
    Desbiolles, Lotus
    Husarik, Daniela
    Frauenfelder, Thomas
    Schmidt, Bernhard
    Allmendinger, Thomas
    Wildermuth, Simon
    Alkadhi, Hatem
    Leschka, Sebastian
    EUROPEAN RADIOLOGY, 2014, 24 (08) : 1889 - 1895
  • [42] High-Pitch CT Pulmonary Angiography in Third Generation Dual-Source CT: Image Quality in an Unselected Patient Population
    Sabel, Bastian O.
    Buric, Kristijan
    Karara, Nora
    Thierfelder, Kolja M.
    Dinkel, Julien
    Sommer, Wieland H.
    Meinel, Felix G.
    PLOS ONE, 2016, 11 (02):
  • [43] Feasibility of a Single Contrast Bolus High-Pitch Pulmonary CT Angiography Protocol Followed by Low-Dose Retrospectively ECG-Gated Cardiac CT in Patients with Suspected Pulmonary Embolism
    Schaefer, Julia Carmen
    Haubenreisser, Holger
    Meyer, Mathias
    Gruettner, Joachim
    Walter, Thomas
    Borggrefe, Martin
    Schoepf, Joseph U.
    Nance, John W., Jr.
    Schoenberg, Stefan O.
    Henzler, Thomas
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2018, 190 (06): : 542 - 550
  • [44] Performance of turbo high-pitch dual-source CT for coronary CT angiography: first ex vivo and patient experience
    Fabian Morsbach
    Sonja Gordic
    Lotus Desbiolles
    Daniela Husarik
    Thomas Frauenfelder
    Bernhard Schmidt
    Thomas Allmendinger
    Simon Wildermuth
    Hatem Alkadhi
    Sebastian Leschka
    European Radiology, 2014, 24 : 1889 - 1895
  • [45] Double prospectively ECG-triggered high-pitch spiral acquisition for CT coronary angiography: Initial experience
    Wang, Q.
    Qin, J.
    He, B.
    Zhou, Y.
    Yang, J-J
    Hou, X. -L.
    Yang, X. -B.
    Chen, J. -H.
    Chen, Y. -D.
    CLINICAL RADIOLOGY, 2013, 68 (08) : 792 - 798
  • [46] Contrast media volume optimization in high-pitch dual-source CT coronary angiography: feasibility study
    Yang, Wen Jie
    Chen, Ke Min
    Liu, Bo
    Pang, Li Fang
    Zhang, Huan
    Pan, Zi Lai
    Yan, Fu Hua
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (01): : 245 - 252
  • [47] Contrast media volume optimization in high-pitch dual-source CT coronary angiography: feasibility study
    Wen Jie Yang
    Ke Min Chen
    Bo Liu
    Li Fang Pang
    Huan Zhang
    Zi Lai Pan
    Fu Hua Yan
    The International Journal of Cardiovascular Imaging, 2013, 29 : 245 - 252
  • [48] Evaluation of high-pitch dual-source CT angiography for evaluation of coronary and carotid-cerebrovascular arteries
    Sun, Kai
    Li, Kuncheng
    Han, Ruijuan
    Li, Wenhuan
    Chen, Nan
    Yang, Qi
    Du, Xiangying
    Wang, Chen
    Liu, Guorong
    Li, Yuechun
    Zhou, Maorong
    Li, Ligang
    Heidrun, Endt
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (03) : 398 - 406
  • [49] Strengths and limitations of coronary angiography with turbo high-pitch third-generation dual-source CT
    Ochs, M. M.
    Andre, F.
    Korosoglou, G.
    Fritz, T.
    Seitz, S.
    Bogomazov, Y.
    Schlett, C. L.
    Sokiranski, R.
    Sommer, A.
    Gueckel, F.
    Brado, M.
    Kauczor, H. -U.
    Goerich, J.
    Buss, S. J.
    CLINICAL RADIOLOGY, 2017, 72 (09) : 739 - 744
  • [50] An iterative reconstruction method for high-pitch helical luggage CT
    Xue, Hui
    Zhang, Li
    Chen, Zhiqiang
    Jin, Xin
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VIII, 2012, 8506