Bolus timing in high-pitch CT angiography of the aorta

被引:14
|
作者
Beeres, Martin [1 ]
Loch, Matthias [1 ]
Schulz, Boris [1 ]
Kerl, Matthias [1 ]
Al-Butmeh, Firas [1 ]
Bodelle, Boris [1 ]
Herrmann, Eva [2 ]
Gruber-Rouh, Tatjana [1 ]
Lee, Clara [1 ]
Jacobi, Volkmar [1 ]
Vogl, Thomas J. [1 ]
Bauer, Ralf W. [1 ]
机构
[1] Clin Goethe Univ, Dept Diagnost & Intervent Radiol, D-60590 Frankfurt, Germany
[2] Clin Goethe Univ, Dept Biostat, D-60590 Frankfurt, Germany
关键词
CT angiography; Aorta; High-pitch CT; Dual-source CT; Bolus geometry; IMAGE QUALITY; INJECTION; PROTOCOLS;
D O I
10.1016/j.ejrad.2013.01.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To investigate the bolus geometry in high-pitch CT angiography (CTA) of the aorta without ECG synchronisation in comparison to single-source CT. Methods: Overall 160 consecutive patients underwent CTA either in conventional single-source mode with a pitch of 1.2 (group 1), or in dual-source mode with a pitch of 3.0 (groups 2, 3 and 4) using different contrast media timings with bolus triggering at 140HU (5 s, group 1; 10 s, group 2; 12 s, group 3; 14 s, group 4). Contrast material, saline flush, flow rate and kV/mAs settings were kept equal for optimum comparability. Aortic attenuation was measured along the z-axis of the patient at different anatomic landmarks and subjective image quality was compared. Results: The most homogeneous enhancement of the aorta was reached with a delay of 10 s after reaching the trigger threshold. The imaging length was not significantly different, but the examination time was significantly (p < 0.001) shorter in the high-pitch group (7.7 s vs. 1.7 s for group 1 vs. 2, 3 and 4). Conclusion: In high-pitch CT angiography using a start delay of 10 s after a trigger threshold of 140HU in the descending aorta is reached, a homogenous contrast along the z-axis is accomplished. (C) 2013 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1028 / 1033
页数:6
相关论文
共 50 条
  • [31] High-pitch dual-source CT coronary angiography: systolic data acquisition at high heart rates
    Goetti, Robert
    Feuchtner, Gudrun
    Stolzmann, Paul
    Desbiolles, Lotus
    Fischer, Michael Alexander
    Karlo, Christoph
    Baumueller, Stephan
    Scheffel, Hans
    Alkadhi, Hatem
    Leschka, Sebastian
    EUROPEAN RADIOLOGY, 2010, 20 (11) : 2565 - 2571
  • [32] High-pitch dual-source CT coronary angiography: systolic data acquisition at high heart rates
    Robert Goetti
    Gudrun Feuchtner
    Paul Stolzmann
    Lotus Desbiolles
    Michael Alexander Fischer
    Christoph Karlo
    Stephan Baumueller
    Hans Scheffel
    Hatem Alkadhi
    Sebastian Leschka
    European Radiology, 2010, 20 : 2565 - 2571
  • [33] The Pattern of Myocardial Perfusion Defects in Patients with Acute Coronary Syndrome Detected by Non-gated High-pitch CT Angiography of Aorta at Emergency Department
    Tsai, Yi-Shan
    Huang, Li-Ting
    Chan, Shih-Hung
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (16) : S4 - S5
  • [34] High-Pitch, Low-Voltage and Low-Iodine-Concentration CT Angiography of Aorta: Assessment of Image Quality and Radiation Dose with Iterative Reconstruction
    Shen, Yanguang
    Sun, Zhonghua
    Xu, Lei
    Li, Yu
    Zhang, Nan
    Yan, Zixu
    Fan, Zhanming
    PLOS ONE, 2015, 10 (02):
  • [35] Optimizing radiation dose by using advanced modelled iterative reconstruction in high-pitch coronary CT angiography
    Gordic, Sonja
    Desbiolles, Lotus
    Sedlmair, Martin
    Manka, Robert
    Plass, Andre
    Schmidt, Bernhard
    Husarik, Daniela B.
    Maisano, Francesco
    Wildermuth, Simon
    Alkadhi, Hatem
    Leschka, Sebastian
    EUROPEAN RADIOLOGY, 2016, 26 (02) : 459 - 468
  • [36] CT-angiography of the aorta in patients with Marfan disease - High-pitch MDCT at different levels of tube voltage combined with Sinogram Affirmed Iterative Reconstruction
    Freyhardt, P.
    Solowjowa, N.
    Boening, G.
    Kahn, J.
    Aufrnesser, B.
    Haage, P.
    Streitparth, F.
    CLINICAL IMAGING, 2018, 51 : 123 - 132
  • [37] Optimizing radiation dose by using advanced modelled iterative reconstruction in high-pitch coronary CT angiography
    Sonja Gordic
    Lotus Desbiolles
    Martin Sedlmair
    Robert Manka
    André Plass
    Bernhard Schmidt
    Daniela B. Husarik
    Francesco Maisano
    Simon Wildermuth
    Hatem Alkadhi
    Sebastian Leschka
    European Radiology, 2016, 26 : 459 - 468
  • [38] Whole-Body High-Pitch CT Angiography: Strategies to Reduce Radiation Dose and Contrast Volume
    Manneck, Sebastian
    Hurwitz, Lynne M.
    Seaman, Danielle M.
    Heye, Tobias
    Boll, Daniel T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 209 (06) : 1396 - 1403
  • [39] Intravenous Contrast Material Administration at High-pitch Dual-source CT Coronary Angiography: Bolus-tracking Technique with Shortened Time of Respiratory Instruction Versus Test Bolus Technique
    Kai Sun
    Guo-rong Liu
    Yue-chun Li
    Rui-juan Han
    Li-fang Cui
    Li-jun Ma
    Li-gang Li
    Chang-yong Li
    ChineseMedicalSciencesJournal, 2012, 27 (04) : 225 - 231
  • [40] Maximizing the clinical benefit of high-pitch, single-heartbeat CT coronary angiography in clinical practice
    St Noble, V.
    Douraghi-Zadeh, D.
    Padley, S. P. G.
    Rubens, M. B.
    Nicol, E. D.
    CLINICAL RADIOLOGY, 2014, 69 (07) : 674 - 677