Bolus timing in high-pitch CT angiography of the aorta

被引:14
|
作者
Beeres, Martin [1 ]
Loch, Matthias [1 ]
Schulz, Boris [1 ]
Kerl, Matthias [1 ]
Al-Butmeh, Firas [1 ]
Bodelle, Boris [1 ]
Herrmann, Eva [2 ]
Gruber-Rouh, Tatjana [1 ]
Lee, Clara [1 ]
Jacobi, Volkmar [1 ]
Vogl, Thomas J. [1 ]
Bauer, Ralf W. [1 ]
机构
[1] Clin Goethe Univ, Dept Diagnost & Intervent Radiol, D-60590 Frankfurt, Germany
[2] Clin Goethe Univ, Dept Biostat, D-60590 Frankfurt, Germany
关键词
CT angiography; Aorta; High-pitch CT; Dual-source CT; Bolus geometry; IMAGE QUALITY; INJECTION; PROTOCOLS;
D O I
10.1016/j.ejrad.2013.01.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To investigate the bolus geometry in high-pitch CT angiography (CTA) of the aorta without ECG synchronisation in comparison to single-source CT. Methods: Overall 160 consecutive patients underwent CTA either in conventional single-source mode with a pitch of 1.2 (group 1), or in dual-source mode with a pitch of 3.0 (groups 2, 3 and 4) using different contrast media timings with bolus triggering at 140HU (5 s, group 1; 10 s, group 2; 12 s, group 3; 14 s, group 4). Contrast material, saline flush, flow rate and kV/mAs settings were kept equal for optimum comparability. Aortic attenuation was measured along the z-axis of the patient at different anatomic landmarks and subjective image quality was compared. Results: The most homogeneous enhancement of the aorta was reached with a delay of 10 s after reaching the trigger threshold. The imaging length was not significantly different, but the examination time was significantly (p < 0.001) shorter in the high-pitch group (7.7 s vs. 1.7 s for group 1 vs. 2, 3 and 4). Conclusion: In high-pitch CT angiography using a start delay of 10 s after a trigger threshold of 140HU in the descending aorta is reached, a homogenous contrast along the z-axis is accomplished. (C) 2013 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1028 / 1033
页数:6
相关论文
共 50 条
  • [21] High-pitch dual-source CT coronary angiography with low volumes of contrast medium
    Lembcke, Alexander
    Schwenke, Carsten
    Hein, Patrick A.
    Knobloch, Gesine
    Durmus, Tahir
    Hamm, Bernd
    Huppertz, Alexander
    EUROPEAN RADIOLOGY, 2014, 24 (01) : 120 - 127
  • [22] Contrast medium application in pediatric high-pitch cardiovascular CT angiography: Manual or power injection?
    Saake, Marc
    Lell, Michael M.
    Rompel, Oliver
    Gloeckler, Martin
    May, Matthias
    Eller, Achim
    Achenbach, Stephan
    Uder, Michael
    Wuest, Wolfgang
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2014, 8 (04) : 315 - 322
  • [23] High-pitch coronary CT angiography with third generation dual-source CT: limits of heart rate
    Gordic, Sonja
    Husarik, Daniela B.
    Desbiolles, Lotus
    Leschka, Sebastian
    Frauenfelder, Thomas
    Alkadhi, Hatem
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (06): : 1173 - 1179
  • [24] High-pitch Dual-source CT Angiography before TAVI - the Value of ECG Gating
    Bucher, Andreas Michael
    Albrecht, Moritz Hans
    Scholtz, Jan Erik
    Herrmann, Eva
    Kaup, Moritz
    Gruber-Rouh, Tatjana
    Jacobi, Volkmar
    Vogl, Thomas Josef
    Beeres, Martin
    CURRENT MEDICAL IMAGING REVIEWS, 2019, 15 (04) : 373 - 379
  • [25] High-pitch coronary CT angiography with third generation dual-source CT: limits of heart rate
    Sonja Gordic
    Daniela B. Husarik
    Lotus Desbiolles
    Sebastian Leschka
    Thomas Frauenfelder
    Hatem Alkadhi
    The International Journal of Cardiovascular Imaging, 2014, 30 : 1173 - 1179
  • [26] Systolic High-Pitch Coronary CT Angiography for Evaluation of the Coronary Arteries in Heart Transplant Recipients
    Bastarrika, Gorka
    Calvo, Marta
    Ezponda, Ana
    Garcia-Baizan, Alejandra
    Caballeros, Meylin
    Rabago, Gregorio
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 215 (04) : 828 - 833
  • [27] High-pitch dual-source CT coronary angiography with low volumes of contrast medium
    Alexander Lembcke
    Carsten Schwenke
    Patrick A. Hein
    Gesine Knobloch
    Tahir Durmus
    Bernd Hamm
    Alexander Huppertz
    European Radiology, 2014, 24 : 120 - 127
  • [28] Highly accelerated, Dixon-based non-contrast MR angiography versus high-pitch CT angiography
    Zeilinger, Martin Georg
    Giese, Daniel
    Schmidt, Michaela
    May, Matthias Stefan
    Janka, Rolf
    Heiss, Rafael
    Ammon, Fabian
    Achenbach, Stephan
    Uder, Michael
    Treutlein, Christoph
    RADIOLOGIA MEDICA, 2024, 129 (02): : 268 - 279
  • [29] Non-ECG-gated high-pitch CT angiography versus hybrid ECG-gated CT angiography for aorta using 512-slice CT: comparison of image quality and radiation dose
    Lee, Jimin
    Jeong, Yeon Joo
    Lee, Geewon
    Kim, Chang Won
    Kim, Jin You
    Lee, Nam Kyung
    Lee, Han Cheol
    Lee, Ji Won
    ACTA RADIOLOGICA, 2023, 64 (02) : 515 - 523
  • [30] Highly accelerated, Dixon-based non-contrast MR angiography versus high-pitch CT angiography
    Martin Georg Zeilinger
    Daniel Giese
    Michaela Schmidt
    Matthias Stefan May
    Rolf Janka
    Rafael Heiss
    Fabian Ammon
    Stephan Achenbach
    Michael Uder
    Christoph Treutlein
    La radiologia medica, 2024, 129 : 268 - 279