Measurement of the radon exhalation rate from the medium surface by tracing the radon concentration

被引:9
|
作者
Tan, Yanliang [1 ]
Xiao, Detao [2 ]
机构
[1] Hengyang Normal Univ, Dept Phys & Elect, Hengyang 421008, Hunan, Peoples R China
[2] Univ S China, Sch Nucl Sci & Technol, Hengyang 421001, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Radon exhalation rate; Accumulation chamber; Tracing the change of radon concentration; Linear fit;
D O I
10.1007/s10967-012-2294-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The paper will present a method based on the accumulation chamber technique for measuring of radon exhalation from the medium surface. A radon monitor traces the change of radon concentration in the accumulation chamber, and then the radon exhalation can be obtained accurately through linear fit. Based on our recent experiments, the radon exhalation rate from the medium surface obtained from this method is in good agreement with the actual exhalation rate of our simulation facility. This method is superior to the competition method which obtains the radon exhalation through the exponential fit by an external PC-system. The calculation for the exponential fit is very easy by computer and related software. However, for portable instruments, the single chip microcomputer can't calculate the exponential fit rapidly. Thus, this method is usable for developing the new portable instrument to classify building materials, etc.
引用
收藏
页码:2295 / 2299
页数:5
相关论文
共 50 条
  • [1] Measurement of the radon exhalation rate from the medium surface by tracing the radon concentration
    Yanliang Tan
    Detao Xiao
    Journal of Radioanalytical and Nuclear Chemistry, 2013, 295 : 2295 - 2299
  • [2] Revision for Measuring the Radon Exhalation Rate From the Medium Surface
    Tan, Yanliang
    Xiao, Detao
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (01) : 209 - 213
  • [3] Measuring radon exhalation rate by tracing the radon concentration of ventilation-type accumulation chamber
    Tan, Yanliang
    Xiao, Detao
    Liu, Xiaosong
    Tang, Quan
    RADIATION MEASUREMENTS, 2013, 58 : 33 - 36
  • [4] RELATIONSHIP BETWEEN RADON EXHALATION RATE FROM GROUND AND ATMOSPHERIC RADON CONCENTRATION
    IKEBE, Y
    YAMANISHI, H
    TOJO, K
    IIDA, T
    JOURNAL OF THE ATOMIC ENERGY SOCIETY OF JAPAN, 1993, 35 (08): : 735 - 738
  • [5] Measurement of radon exhalation rate and soil gas radon concentration in areas of southern Punjab, Pakistan
    Mujahid, S. A.
    Hussain, S.
    Ramzan, M.
    RADIATION PROTECTION DOSIMETRY, 2010, 140 (03) : 300 - 303
  • [6] A simple model for automatically measuring radon exhalation rate from medium surface
    Tan, Yanliang
    Xiao, Detao
    RADIATION MEASUREMENTS, 2014, 64 : 44 - 47
  • [7] Evaluation and measurement methods for the surface radon exhalation rate of buildings
    Lv, Lidan
    He, Zhengzhong
    Qiu, Shoukang
    Tang, Quan
    INDOOR AND BUILT ENVIRONMENT, 2022, 31 (10) : 2378 - 2385
  • [8] Suitability evaluation of measurement method for radon exhalation rate of porous medium containing radon adsorbing materials
    Wang, Haofeng
    Ye, Yongjun
    Yao, Xuanli
    Luo, Liling
    JOURNAL OF HAZARDOUS MATERIALS, 2025, 490
  • [9] Laboratory study on the relationship between the vertical distribution of radon concentration in soil and the exhalation rate of radon from the soil surface
    Wu, Jiulin
    Xie, Ruomei
    Yi, Haibo
    Hu, Tao
    Sun, Jiale
    Liu, Zhipeng
    Li, Huiying
    Liu, Shuaibin
    Yuan, Shuai
    Tan, Yanliang
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2024, 333 (12) : 6149 - 6154
  • [10] The effect of some soil characteristics on soil radon concentration and radon exhalation from soil surface
    Sun, KN
    Gu, QJ
    Cheng, JP
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2004, 41 (11) : 1113 - 1117