Measurement of the radon exhalation rate from the medium surface by tracing the radon concentration

被引:9
|
作者
Tan, Yanliang [1 ]
Xiao, Detao [2 ]
机构
[1] Hengyang Normal Univ, Dept Phys & Elect, Hengyang 421008, Hunan, Peoples R China
[2] Univ S China, Sch Nucl Sci & Technol, Hengyang 421001, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Radon exhalation rate; Accumulation chamber; Tracing the change of radon concentration; Linear fit;
D O I
10.1007/s10967-012-2294-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The paper will present a method based on the accumulation chamber technique for measuring of radon exhalation from the medium surface. A radon monitor traces the change of radon concentration in the accumulation chamber, and then the radon exhalation can be obtained accurately through linear fit. Based on our recent experiments, the radon exhalation rate from the medium surface obtained from this method is in good agreement with the actual exhalation rate of our simulation facility. This method is superior to the competition method which obtains the radon exhalation through the exponential fit by an external PC-system. The calculation for the exponential fit is very easy by computer and related software. However, for portable instruments, the single chip microcomputer can't calculate the exponential fit rapidly. Thus, this method is usable for developing the new portable instrument to classify building materials, etc.
引用
收藏
页码:2295 / 2299
页数:5
相关论文
共 50 条
  • [41] In-situ measurement via the flow-through method and numerical simulations for radon exhalation during measurements of the radon exhalation rate
    Xia, Ming
    Ye, Yong-Jun
    Shang, Shan-Wei
    Yu, Ting
    Chen, Dai-Jia
    NUCLEAR SCIENCE AND TECHNIQUES, 2024, 35 (07)
  • [42] In-situ measurement via the flow-through method and numerical simulations for radon exhalation during measurements of the radon exhalation rate
    Ming Xia
    YongJun Ye
    ShanWei Shang
    Ting Yu
    DaiJia Chen
    NuclearScienceandTechniques, 2024, 35 (07) : 28 - 43
  • [43] RADON EXHALATION FROM THE SOIL
    KELLER, G
    SCHUTZ, M
    RADIATION PROTECTION DOSIMETRY, 1988, 24 (1-4) : 43 - 46
  • [44] SOIL RADON EXHALATION RATE MEASUREMENT IN DUHOK CITY BY TWO TECHNIQUES
    Alhamdi, Walat A. H.
    Abdullah, Khairi M-S
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2022, 37 (03): : 229 - 234
  • [46] Measurement of radon exhalation rate from building materials: The case of Highland Region of Ecuador
    Tene, Talia
    Vacacela Gomez, Cristian
    Tubon Usca, Gabriela
    Suquillo, Betzabeth
    Bellucci, Stefano
    CONSTRUCTION AND BUILDING MATERIALS, 2021, 293
  • [47] Study of Indoor Radon, Thoron, Their Progeny Concentration and Radon Exhalation Rate in the Environs of Mohali, Punjab, Northern India
    Mehta, Vimal
    Singh, Supreet Pal
    Chauhan, Rishi Pal
    Mudahar, Gurmel Singh
    AEROSOL AND AIR QUALITY RESEARCH, 2015, 15 (04) : 1380 - 1389
  • [48] Measurement of radioactivity and radon exhalation rate in different kinds of marbles and granites
    El-Dine, NW
    El-Shershaby, A
    Ahmed, F
    Abdel-Haleem, AS
    APPLIED RADIATION AND ISOTOPES, 2001, 55 (06) : 853 - 860
  • [49] Measurement of radon exhalation rate and radiation doses in fly ash samples
    Sharma, Anil
    Pandit, Pragya
    Attri, Asha
    Acharya, Sanigdha
    RADIATION PROTECTION DOSIMETRY, 2024, 200 (11-12) : 1127 - 1131
  • [50] Measurement of radon exhalation rate in various building materials and soil samples
    Pankaj Bala
    Vinod Kumar
    Rohit Mehra
    Journal of Earth System Science, 2017, 126