Measurement of the radon exhalation rate from the medium surface by tracing the radon concentration

被引:9
|
作者
Tan, Yanliang [1 ]
Xiao, Detao [2 ]
机构
[1] Hengyang Normal Univ, Dept Phys & Elect, Hengyang 421008, Hunan, Peoples R China
[2] Univ S China, Sch Nucl Sci & Technol, Hengyang 421001, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Radon exhalation rate; Accumulation chamber; Tracing the change of radon concentration; Linear fit;
D O I
10.1007/s10967-012-2294-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The paper will present a method based on the accumulation chamber technique for measuring of radon exhalation from the medium surface. A radon monitor traces the change of radon concentration in the accumulation chamber, and then the radon exhalation can be obtained accurately through linear fit. Based on our recent experiments, the radon exhalation rate from the medium surface obtained from this method is in good agreement with the actual exhalation rate of our simulation facility. This method is superior to the competition method which obtains the radon exhalation through the exponential fit by an external PC-system. The calculation for the exponential fit is very easy by computer and related software. However, for portable instruments, the single chip microcomputer can't calculate the exponential fit rapidly. Thus, this method is usable for developing the new portable instrument to classify building materials, etc.
引用
收藏
页码:2295 / 2299
页数:5
相关论文
共 50 条
  • [31] Comparison of indoor radon level with radon exhalation rate from soil in Garhwal Himalaya
    Gusain, G. S.
    Prasad, Ganesh
    Prasad, Yogesh
    Ramola, R. C.
    RADIATION MEASUREMENTS, 2009, 44 (9-10) : 1032 - 1035
  • [32] Effect of humidity on radon exhalation rate from concrete
    Yamanishi, H
    Obayashi, H
    Tsuji, N
    Nakayoshi, H
    RADON AND THORON IN THE HUMAN ENVIRONMENT, 1998, : 429 - 434
  • [33] The influence of precipitation on radon exhalation rate
    Rehs, B
    Wendt, J
    Reineking, A
    Porstendörfer, J
    RADIOACTIVITY IN HUMANS AND THE ENVIRONMENT, 1998, : 373 - 378
  • [34] IN—SITU MEASUREMENTS OF RADON EXHALATION RATE FROM BUILDING SURFACE IN HONG KONG
    余君岳
    关祖杰
    杨健明
    M.J.Stokes
    NuclearScienceandTechniques, 1993, (03) : 176 - 180
  • [35] Measurement of the radon and thoron exhalation rates from the water surface of Yixin lake
    Wu, Jiulin
    Liu, Shuaibin
    Hu, Tao
    Lin, Fen
    Xie, Ruomei
    Yuan, Shuai
    Yi, Haibo
    Mo, Yixiang
    Sun, Jiale
    Cheng, Linquan
    Li, Huiying
    Liu, Zhipeng
    Fan, Zhongkai
    Tan, Yanliang
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2024, 56 (04) : 1538 - 1543
  • [36] Evaluation of radon exhalation rate from granite stone
    Nassiri, P.
    Ebrahimi, H.
    Shalkouhi, P. Jafari
    JOURNAL OF SCIENTIFIC & INDUSTRIAL RESEARCH, 2011, 70 (03): : 230 - 231
  • [37] Study of radon/thoron exhalation rate, soil-gas radon concentration, and assessment of indoor radon/thoron concentration in Siwalik Himalayas of Jammu & Kashmir
    Kaur, Manpreet
    Kumar, Ajay
    Mehra, Rohit
    Mishra, Rosaline
    HUMAN AND ECOLOGICAL RISK ASSESSMENT, 2018, 24 (08): : 2275 - 2287
  • [38] Radon-222 concentration in subsoils and its exhalation rate from a soil sample
    Denagbe, SJ
    RADIATION MEASUREMENTS, 2000, 32 (01) : 27 - 34
  • [39] No flow meter method for measuring radon exhalation from the medium surface with a ventilation chamber
    Tan, Yanliang
    Yuan, Hongzhi
    Xie, Yuxi
    Liu, Can
    Liu, Xiaosong
    Fan, Zhongkai
    Kearfott, Kimberlee
    APPLIED RADIATION AND ISOTOPES, 2020, 166
  • [40] Field measurement of radon exhalation rate from the soil by CR-39 detector
    A. Vasidov
    Journal of Radioanalytical and Nuclear Chemistry, 2014, 302 : 919 - 923