A simple model for automatically measuring radon exhalation rate from medium surface

被引:8
|
作者
Tan, Yanliang [1 ,2 ]
Xiao, Detao [2 ]
机构
[1] Hengyang Normal Univ, Dept Phys & Elect, Hengyang City 421008, Hunan, Peoples R China
[2] Univ South China, Sch Nucl Sci & Technol, Hengyang City 421001, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Simple model; Radon exhalation rate; Sufficient condition;
D O I
10.1016/j.radmeas.2014.04.006
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A simple model to measure radon exhalation rate from medium surface is developed in this paper. This model is based on a combination of the "accumulation chamber" technique and a radon monitor. The radon monitor is used to perform measurement of radon concentration evolution inside the accumulation chamber, and radon exhalation rate is evaluated via nonlinear least-square fitting of the measured data. If the flow rate of the pump is high enough, radon concentration in the detector's internal cell becomes to be equal to that in the accumulation chamber quickly, and the simple model for measuring the radon exhalation rate can be generated analytically. Generally, the pump flow rate of radon monitor is low, not satisfying the condition. We find other sufficient conditions of this simplified model. On these conditions, the radon exhalation rate can be calculated accurately through this model even the flow rate of the pump is not so high. This method can be applied to develop and improve the instruments for measuring the radon exhalation rate. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:44 / 47
页数:4
相关论文
共 50 条
  • [1] Revision for Measuring the Radon Exhalation Rate From the Medium Surface
    Tan, Yanliang
    Xiao, Detao
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (01) : 209 - 213
  • [2] Measurement of the radon exhalation rate from the medium surface by tracing the radon concentration
    Tan, Yanliang
    Xiao, Detao
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2013, 295 (03) : 2295 - 2299
  • [3] Measurement of the radon exhalation rate from the medium surface by tracing the radon concentration
    Yanliang Tan
    Detao Xiao
    Journal of Radioanalytical and Nuclear Chemistry, 2013, 295 : 2295 - 2299
  • [4] A simple device for measuring radon exhalation from the ground
    Savvides, E.
    Manolopoulou, M.
    Papastefanou, C.
    Charalambous, S.
    International Journal of Applied Radiation and Isotopes, 1985, 36 (01): : 79 - 81
  • [5] A SIMPLE DEVICE FOR MEASURING RADON EXHALATION FROM THE GROUND
    SAVVIDES, E
    MANOLOPOULOU, M
    PAPASTEFANOU, C
    CHARALAMBOUS, S
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1985, 36 (01): : 79 - 81
  • [6] No flow meter method for measuring radon exhalation from the medium surface with a ventilation chamber
    Tan, Yanliang
    Yuan, Hongzhi
    Xie, Yuxi
    Liu, Can
    Liu, Xiaosong
    Fan, Zhongkai
    Kearfott, Kimberlee
    APPLIED RADIATION AND ISOTOPES, 2020, 166
  • [7] SIMPLE METHOD FOR MEASURING THE RADON DIFFUSION-COEFFICIENT AND EXHALATION RATE FROM BUILDING-MATERIALS
    STRANDEN, E
    HEALTH PHYSICS, 1979, 37 (02): : 242 - 244
  • [8] Revision for measuring radon exhalation rate in open loop
    Tan, Y.
    Xiao, D.
    Yuan, H.
    Tang, Q.
    Liu, X.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [9] Measuring radon exhalation rate through three cycles
    Tan, Y.
    Xiao, D.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [10] Determination of representative elementary surface for accurately measuring radon exhalation rate in masonry wall
    Chen, Mengge
    Ye, Yongjun
    Zhou, Ning
    Yao, Xuanli
    JOURNAL OF HAZARDOUS MATERIALS, 2025, 482