Quantifying cellular oxidative stress by dichlorofluorescein assay using microplate reader

被引:2031
|
作者
Wang, H [1 ]
Joseph, JA [1 ]
机构
[1] Tufts Univ, USDA ARS, HNRCA, Neurosci Lab, Boston, MA 02111 USA
关键词
oxidative stress; dichlorofluorescin; free radicals; dopamine; hydrogen peroxide; AAPH; SIN-1; sodium nitroprusside;
D O I
10.1016/S0891-5849(99)00107-0
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Oxidative stress (OS) has been implicated in various degenerative diseases in aging. In an attempt to quantify OS in a cell model, we examined OS induced by incubating for 30 min with various free radical generators in PC12 cells by using the dichlorofluorescein (DCF) assay, modified for use by a fluorescent microplate reader. The nonfluorescent fluorescin derivatives (dichlorofluorescin, DCFH), after being oxidized by various oxidants, will become DCF and emit fluorescence. By quantifying the fluorescence, we were able to quantify the OS. Our results indicated that the fluorescence varied linearly with increasing concentrations (between 0.1 and 1 mM) of H2O2 and 2,2'-azobios(2-amidinopropane) dihydrochloride (AAPH; a peroxyl radical generator). By contrast, the fluorescence varied as a nonlinear response to increasing concentrations of 3-morpholinosydnonimine hydrochloride (SIN-1; a peroxynitrite generator), sodium nitroprusside (SNP; a nitric oxide generator), and dopamine. Dopamine had a biphasic effect; it decreased the DCF fluorescence, thus acting as an antioxidant, at concentrations <500 mu M in cells, but acted as a pro-oxidant by increasing the fluorescence at 1 mM. While SNP was not a strong pro-oxidant, SIN-1 was the most potent pro-oxidant among those tested, inducing a 70 times increase of fluorescence at a concentration of 100 mu M compared with control. Collectively, due to its indiscriminate nature to various free radicals, DCF can be very useful in quantifying overall OS in cells, especially when used in conjunction with a fluorescent microplate reader. This method is reliable and efficient for evaluating the potency of pro-oxidants and can be used to evaluate the efficacy of antioxidants against OS in cells. (C) 1999 Elsevier Science Inc.
引用
收藏
页码:612 / 616
页数:5
相关论文
共 50 条
  • [41] DETERMINATION OF NITRATE LEVELS IN WATER SAMPLES USING A MICROPLATE READER
    STANLEY, CD
    JONES, JB
    SOIL AND CROP SCIENCE SOCIETY OF FLORIDA PROCEEDINGS, 1992, 51 : 56 - 58
  • [42] Early Perspective: Microplate Applications of the Cellular Thermal Shift Assay (CETSA)
    Seashore-Ludlow, Brinton
    Lundback, Thomas
    JOURNAL OF BIOMOLECULAR SCREENING, 2016, 21 (10) : 1019 - 1033
  • [43] Microplate assay for quantifying developmental morphologies: effects of exogenous hyalin on sea urchin gastrulation
    Razinia, Z.
    Carroll, E. J., Jr.
    Oppenheimer, S. B.
    ZYGOTE, 2007, 15 (02) : 159 - 164
  • [44] Photoreduction of 2′-7′-dichlorofluorescein.: An ESR study with implications for oxidative stress measurements
    Rota, C
    Marchesi, E
    Chignell, CF
    Mason, RP
    FREE RADICAL BIOLOGY AND MEDICINE, 1998, 25 : S102 - S102
  • [45] USE OF A MICROPLATE READER IN AN ASSAY OF GLUTATHIONE-REDUCTASE USING 5,5'-DITHIOBIS(2-NITROBENZOIC ACID)
    CRIBB, AE
    LEEDER, JS
    SPIELBERG, SP
    ANALYTICAL BIOCHEMISTRY, 1989, 183 (01) : 195 - 196
  • [46] MICROPLATE READER ASSAY FOR MEASUREMENT OF OPSONIZED ZYMOSAN-STIMULATED SUPEROXIDE ANION PRODUCTION BY NEUTROPHILS
    CAREY, LA
    SCHUHL, RA
    GEE, MH
    BIOTECHNIQUES, 1995, 19 (05) : 824 - 829
  • [47] A novel microplate reader-based high-throughput assay for estrogen receptor binding
    Gurer-Orhan, H
    Kool, J
    Vermeulen, NPE
    Meerman, JHN
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2005, 85 (03) : 149 - 161
  • [48] Scanometry as microplate reader for high throughput method based on DPPH dry reagent for antioxidant assay
    Mochammad Amrun Hidayat
    Aulia Fitri
    Bambang Kuswandi
    ActaPharmaceuticaSinicaB, 2017, 7 (03) : 395 - 400
  • [49] Detection of reactive oxygen species induced by radiation in cells using the dichlorofluorescein assay
    Korystov, Yuri N.
    Shaposhnikova, Vera V.
    Korystova, Antonina F.
    Emel'yanov, Maksim O.
    RADIATION RESEARCH, 2007, 168 (02) : 226 - 232
  • [50] High Throughput Screening of Pyruvic Acid in Onions using Microplate Reader
    Kulkarni, Akshata
    Uckoo, Ram M.
    Jayaprakasha, G. K.
    Patil, Bhimanagouda S.
    HORTSCIENCE, 2013, 48 (09) : S235 - S235