Quantifying cellular oxidative stress by dichlorofluorescein assay using microplate reader

被引:2031
|
作者
Wang, H [1 ]
Joseph, JA [1 ]
机构
[1] Tufts Univ, USDA ARS, HNRCA, Neurosci Lab, Boston, MA 02111 USA
关键词
oxidative stress; dichlorofluorescin; free radicals; dopamine; hydrogen peroxide; AAPH; SIN-1; sodium nitroprusside;
D O I
10.1016/S0891-5849(99)00107-0
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Oxidative stress (OS) has been implicated in various degenerative diseases in aging. In an attempt to quantify OS in a cell model, we examined OS induced by incubating for 30 min with various free radical generators in PC12 cells by using the dichlorofluorescein (DCF) assay, modified for use by a fluorescent microplate reader. The nonfluorescent fluorescin derivatives (dichlorofluorescin, DCFH), after being oxidized by various oxidants, will become DCF and emit fluorescence. By quantifying the fluorescence, we were able to quantify the OS. Our results indicated that the fluorescence varied linearly with increasing concentrations (between 0.1 and 1 mM) of H2O2 and 2,2'-azobios(2-amidinopropane) dihydrochloride (AAPH; a peroxyl radical generator). By contrast, the fluorescence varied as a nonlinear response to increasing concentrations of 3-morpholinosydnonimine hydrochloride (SIN-1; a peroxynitrite generator), sodium nitroprusside (SNP; a nitric oxide generator), and dopamine. Dopamine had a biphasic effect; it decreased the DCF fluorescence, thus acting as an antioxidant, at concentrations <500 mu M in cells, but acted as a pro-oxidant by increasing the fluorescence at 1 mM. While SNP was not a strong pro-oxidant, SIN-1 was the most potent pro-oxidant among those tested, inducing a 70 times increase of fluorescence at a concentration of 100 mu M compared with control. Collectively, due to its indiscriminate nature to various free radicals, DCF can be very useful in quantifying overall OS in cells, especially when used in conjunction with a fluorescent microplate reader. This method is reliable and efficient for evaluating the potency of pro-oxidants and can be used to evaluate the efficacy of antioxidants against OS in cells. (C) 1999 Elsevier Science Inc.
引用
收藏
页码:612 / 616
页数:5
相关论文
共 50 条
  • [21] A microplate-based DCFH-DA assay for the evaluation of oxidative stress in whole semen
    Benedetti, Serena
    Catalani, Simona
    De Stefani, Silvia
    Primiterra, Mariangela
    Fraternale, Alessandra
    Palma, Francesco
    Palini, Simone
    HELIYON, 2022, 8 (09)
  • [22] Development of LEDs-based microplate reader for bioanalytical assay measurements
    Alaruri, Sami D.
    Katzlinger, Michael
    Schinwald, Bernhard
    Kronberger, Georg
    Atzler, Joseph
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2013, 24 (10)
  • [23] A microplate reader-based nonisotopic histone deacetylase activity assay
    Heltweg, B
    Jung, M
    ANALYTICAL BIOCHEMISTRY, 2002, 302 (02) : 175 - 183
  • [24] Application of the bicinchoninic method of assay for the reducing sugars to determine carboxymethylcellulase activity of cellulases using a microplate reader
    Zorov, IN
    Dubasova, MY
    Sinitsyn, AP
    Gusakov, AV
    Mitchenko, AA
    Baraznenok, VA
    Gutyerres, B
    Popova, NN
    BIOCHEMISTRY-MOSCOW, 1997, 62 (07) : 704 - 709
  • [25] A MICROPLATE ASSAY FOR THE DETECTION OF OXIDATIVE PRODUCTS USING 2',7'-DICHLOROFLUORESCIN-DIACETATE
    ROSENKRANZ, AR
    SCHMALDIENST, S
    STUHLMEIER, KM
    CHEN, WJ
    KNAPP, W
    ZLABINGER, GJ
    JOURNAL OF IMMUNOLOGICAL METHODS, 1992, 156 (01) : 39 - 45
  • [26] Lactate dehydrogenase kinetics and inhibition using a microplate reader
    Powers, Jennifer L.
    Kiesman, Natalie E.
    Tran, Connie M.
    Brown, John H.
    Bevilacqua, Vicky L. H.
    BIOCHEMISTRY AND MOLECULAR BIOLOGY EDUCATION, 2007, 35 (04) : 287 - 292
  • [27] RAPID METHOD FOR DETERMINING AMYLOSE USING A MICROPLATE READER
    COBB, BG
    SCHOELLES, DB
    HORTSCIENCE, 1989, 24 (03) : 487 - 488
  • [28] USING A MICROPLATE READER TO QUANTIFY DOT IMMUNOBINDING ASSAYS
    FERREIRA, MU
    STOLF, AMS
    FERREIRA, CS
    KATZIN, AM
    RAMOS, AMSV
    KIMURA, E
    DISANTI, SM
    CAMARGO, LMA
    MEMORIAS DO INSTITUTO OSWALDO CRUZ, 1991, 86 (04): : 467 - 468
  • [29] Use of a microplate reader for protein assays and a fixed-time kinetic assay
    Powers, JL
    Kiesman, N
    Tran, C
    Jain, S
    Brown, J
    Bevilacqua, VLH
    FASEB JOURNAL, 2005, 19 (05): : A1395 - A1395
  • [30] A Fluorescence Microplate Assay Using Yopro-1 to measure apoptosis: Application to HL60 Cells Subjected to Oxidative stress
    E. Plantin-Carrenard
    A. Bringuier
    C. Derappe
    J. Pichon
    R. Guillot
    M. Bernard
    M.J. foglietti
    G. Feldmann
    M. Aubery
    F. Braut-Boucher
    Cell Biology and Toxicology, 2003, 19 : 121 - 133