Quantifying cellular oxidative stress by dichlorofluorescein assay using microplate reader

被引:2031
|
作者
Wang, H [1 ]
Joseph, JA [1 ]
机构
[1] Tufts Univ, USDA ARS, HNRCA, Neurosci Lab, Boston, MA 02111 USA
关键词
oxidative stress; dichlorofluorescin; free radicals; dopamine; hydrogen peroxide; AAPH; SIN-1; sodium nitroprusside;
D O I
10.1016/S0891-5849(99)00107-0
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Oxidative stress (OS) has been implicated in various degenerative diseases in aging. In an attempt to quantify OS in a cell model, we examined OS induced by incubating for 30 min with various free radical generators in PC12 cells by using the dichlorofluorescein (DCF) assay, modified for use by a fluorescent microplate reader. The nonfluorescent fluorescin derivatives (dichlorofluorescin, DCFH), after being oxidized by various oxidants, will become DCF and emit fluorescence. By quantifying the fluorescence, we were able to quantify the OS. Our results indicated that the fluorescence varied linearly with increasing concentrations (between 0.1 and 1 mM) of H2O2 and 2,2'-azobios(2-amidinopropane) dihydrochloride (AAPH; a peroxyl radical generator). By contrast, the fluorescence varied as a nonlinear response to increasing concentrations of 3-morpholinosydnonimine hydrochloride (SIN-1; a peroxynitrite generator), sodium nitroprusside (SNP; a nitric oxide generator), and dopamine. Dopamine had a biphasic effect; it decreased the DCF fluorescence, thus acting as an antioxidant, at concentrations <500 mu M in cells, but acted as a pro-oxidant by increasing the fluorescence at 1 mM. While SNP was not a strong pro-oxidant, SIN-1 was the most potent pro-oxidant among those tested, inducing a 70 times increase of fluorescence at a concentration of 100 mu M compared with control. Collectively, due to its indiscriminate nature to various free radicals, DCF can be very useful in quantifying overall OS in cells, especially when used in conjunction with a fluorescent microplate reader. This method is reliable and efficient for evaluating the potency of pro-oxidants and can be used to evaluate the efficacy of antioxidants against OS in cells. (C) 1999 Elsevier Science Inc.
引用
收藏
页码:612 / 616
页数:5
相关论文
共 50 条
  • [31] A fluorescence microplate assay using yopro-1 to measure apoptosis: Application to HL60 cells subjected to oxidative stress
    Plantin-Carrenard, E
    Bringuier, A
    Derappe, C
    Pichon, J
    Guillot, R
    Bernard, M
    Foglietti, MJ
    Feldmann, G
    Aubery, M
    Braut-Boucher, F
    CELL BIOLOGY AND TOXICOLOGY, 2003, 19 (02) : 121 - 133
  • [32] A MICROPLATE READER ASSAY FOR RAPID ENZYMATIC QUANTIFICATION OF SUGARS IN POTATO-TUBERS
    VIOLA, R
    DAVIES, HV
    POTATO RESEARCH, 1992, 35 (01) : 55 - 58
  • [33] DETECTION OF PICOMOLE LEVELS OF HYDROPEROXIDES USING A FLUORESCENT DICHLOROFLUORESCEIN ASSAY
    CATHCART, R
    SCHWIERS, E
    AMES, BN
    ANALYTICAL BIOCHEMISTRY, 1983, 134 (01) : 111 - 116
  • [34] Dihydrofolate reductase enzyme inhibition assay for plasma methotrexate determination using a 96-well microplate reader
    Widemann, BC
    Balis, FM
    Adamson, PC
    CLINICAL CHEMISTRY, 1999, 45 (02) : 223 - 228
  • [35] Microplate assay for quantifying developmental morphologies: Effects of hyalin on sea urchin gastrulation
    Razinia, Ziba
    Carroll, Edward J., Jr.
    Oppenheimer, Steven B.
    FASEB JOURNAL, 2007, 21 (06): : A1155 - A1155
  • [36] Evaluation of the oxidative stress in growing pigs by microplate assays
    Brambilla, G
    Fiori, M
    Archetti, LI
    JOURNAL OF VETERINARY MEDICINE SERIES A-PHYSIOLOGY PATHOLOGY CLINICAL MEDICINE, 2001, 48 (01): : 33 - 38
  • [37] DETECTION OF PICOMOLE LEVELS OF LIPID HYDROPEROXIDES USING A DICHLOROFLUORESCEIN FLUORESCENT ASSAY
    CATHCART, R
    SCHWIERS, E
    AMES, BN
    METHODS IN ENZYMOLOGY, 1984, 105 : 352 - 358
  • [38] A fast and reliable microplate reader assay to assess the antiviral efficacy of cold plasma devices
    Bekeschus, Sander
    Skowski, Henry
    Hahn, Veronika
    Bansemer, Robert
    Gerling, Torsten
    Weltmann, Klaus-Dieter
    von Woedtke, Thomas
    PLASMA PROCESSES AND POLYMERS, 2024, 21 (10)
  • [39] Cellular Oxidative Stress
    Dossena, Silvia
    Marino, Angela
    ANTIOXIDANTS, 2021, 10 (03)
  • [40] AN IMPROVED METHOD FOR DETECTION OF HEMAGGLUTINATION USING AN AUTOMATED MICROPLATE READER
    SEVERNS, ML
    KLINE, LM
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (05) : 349 - 352