Effect of Calibration and Environmental Condition on the Performance of Direct-Reading Organic Vapor Monitors

被引:10
|
作者
Coffey, Christopher [1 ]
LeBouf, Ryan [2 ]
Lee, Larry [3 ]
Slaven, James [3 ]
Martin, Stephen [2 ]
机构
[1] NIOSH, Natl Personal Protect Technol Lab, Morgantown, WV 26505 USA
[2] NIOSH, Div Resp Dis Studies, Morgantown, WV 26505 USA
[3] NIOSH, Hlth Effects Lab Div, Morgantown, WV 26505 USA
关键词
direct-reading organic vapor monitors; flame ionization detector; photoionization detector; SapphIRe; toxic vapor analyzer; IONIZATION GAS-CHROMATOGRAPH; PHOTOIONIZATION DETECTOR; ATMOSPHERES; EXPOSURE;
D O I
10.1080/15459624.2012.725015
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The performance of three MIRAN SapphIRe Portable Infrared Ambient Air Analyzers and three Century Portable Toxic Vapor Analyzers equipped with photoionization (PID) and flame ionization (FID) detectors was compared with charcoal tube sampling. Relationships were investigated using two different calibration methods at four cyclohexane concentrations, three temperatures, and four relative humidities. For the first method, the TVA monitors were calibrated with a single concentration of methane for the FID, and isobutylene for the PID. The SapphIRe monitors were zeroed and the monitor's manufacturer-supplied library was used. For the second method, a five-point cyclohexane calibration curve was created for each monitor Comparison of the monitor results of each calibration method (pooled data) indicated a significant difference between methods (t-test, p < 0.001), The SapphIRe group had results closer to the charcoal tubes with the second calibration method, while the PID and FID monitor groups performed better using the first calibration method. The PID monitor group's performance was affected only at the 90% relative humidity (RH) condition. Using the first method, the monitor readings were compared with the charcoal tube average using mixed linear model analyses of variance (ANOVAs) and regression. The ANOVA results showed there was a statistically significant difference among readings from all monitor types (p <0.0001). The regression results demonstrated that the SapphIRe (r(2) = 0.97) and FID (r(2) = 0.92) monitor groups correlated well with the charcoal tubes. The PID monitor group had a similar correlation when 90% RH was excluded (r(2) = 0.94) but had a weaker correlation when it was included (r(2) = 0.58). The operator should take care when using these monitors at high concentrations and the PID monitors at high humidities, consider the variability between units of the same monitor, and conduct performance verification of the monitor being used.
引用
收藏
页码:670 / 680
页数:11
相关论文
共 50 条
  • [41] THE EFFECT OF SQUARE-WAVE EXPOSURE PROFILES UPON THE PERFORMANCE OF PASSIVE ORGANIC VAPOR MONITORING BADGES
    COMPTON, JR
    DWIGGINS, GA
    FEIGLEY, CE
    LUDWIG, DA
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1984, 45 (07): : 446 - 450
  • [42] Direct evidence for effect of molecular orientation on thermoelectric performance of organic polymer materials by infrared dichroism
    Xu, Kongli
    Gao, Caiyan
    Chen, Guangming
    Qiu, Dong
    ORGANIC ELECTRONICS, 2016, 31 : 41 - 47
  • [43] Effect of Swelling Treatment by Organic Solvent on the Structure and Pyrolysis Performance of the Direct Coal Liquefaction Residue
    He, Xiao-Qiang
    Mo, Wen-Long
    Wang, Qiang
    Ma, Ya-Ya
    Ma, Feng-Yun
    Fan, Xing
    Wei, Xian-Yong
    ENERGY & FUELS, 2020, 34 (07) : 8685 - 8696
  • [44] Direct vapor-phase synthesis of indole:: Effect of MgO on the performance CU/SiO2 catalyst
    Liu Jing
    Li Chunmei
    Huo Xiaomin
    Shi Lei
    Sun Qi
    CHINESE JOURNAL OF CATALYSIS, 2008, 29 (02) : 159 - 162
  • [45] The effect of vapor-grown carbon fiber as an additive to the catalyst layer on the performance of a direct methanol fuel cell
    Park, Sang-Min
    Jung, Doo-Hwan
    Kim, Sang-Kyung
    Lim, Seongyop
    Peck, Donghyun
    Hong, Won Hi
    ELECTROCHIMICA ACTA, 2009, 54 (11) : 3066 - 3072
  • [46] Performance Enhancement in TIPS-pentacene: PS Blend Organic Field Effect Transistors by Solvent Vapor Annealing
    Bharti, Deepak
    Varun, Ishan
    Tiwari, Shree Prakash
    2016 74TH ANNUAL DEVICE RESEARCH CONFERENCE (DRC), 2016,
  • [47] Optimization of exergetic performance and payback period of organic rankine cycle integrated vapor compression refrigeration system based on exergy, economic, and environmental criteria
    Goyal, Ashwni
    Sherwani, Ahmad Faizan
    JOURNAL OF THERMAL ENGINEERING, 2023, 9 (03): : 648 - 658
  • [48] Effect of interactions between ammonium and organic fouling simulated by sodium alginate on performance of direct contact membrane distillation
    Tibi, Fida
    Charfi, Amine
    Cho, Jinwoo
    Kim, Jeonghwan
    SEPARATION AND PURIFICATION TECHNOLOGY, 2022, 278
  • [49] Structure-Performance Correlations in Vapor Phase Deposited Self-Assembled Nanodielectrics for Organic Field-Effect Transistors
    DiBenedetto, Sara A.
    Frattarelli, David L.
    Facchetti, Antonio
    Ratner, Mark A.
    Marks, Tobin J.
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2009, 131 (31) : 11080 - 11090
  • [50] High Performance and Stable N-Channel Organic Field-Effect Transistors by Patterned Solvent-Vapor Annealing
    Khim, Dongyoon
    Baeg, Kang-Jun
    Kim, Juhwan
    Kang, Minji
    Lee, Seung-Hoon
    Chen, Zhihua
    Facchetti, Antonio
    Kim, Dong-Yu
    Noh, Yong-Young
    ACS APPLIED MATERIALS & INTERFACES, 2013, 5 (21) : 10745 - 10752