Effect of Calibration and Environmental Condition on the Performance of Direct-Reading Organic Vapor Monitors

被引:10
|
作者
Coffey, Christopher [1 ]
LeBouf, Ryan [2 ]
Lee, Larry [3 ]
Slaven, James [3 ]
Martin, Stephen [2 ]
机构
[1] NIOSH, Natl Personal Protect Technol Lab, Morgantown, WV 26505 USA
[2] NIOSH, Div Resp Dis Studies, Morgantown, WV 26505 USA
[3] NIOSH, Hlth Effects Lab Div, Morgantown, WV 26505 USA
关键词
direct-reading organic vapor monitors; flame ionization detector; photoionization detector; SapphIRe; toxic vapor analyzer; IONIZATION GAS-CHROMATOGRAPH; PHOTOIONIZATION DETECTOR; ATMOSPHERES; EXPOSURE;
D O I
10.1080/15459624.2012.725015
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The performance of three MIRAN SapphIRe Portable Infrared Ambient Air Analyzers and three Century Portable Toxic Vapor Analyzers equipped with photoionization (PID) and flame ionization (FID) detectors was compared with charcoal tube sampling. Relationships were investigated using two different calibration methods at four cyclohexane concentrations, three temperatures, and four relative humidities. For the first method, the TVA monitors were calibrated with a single concentration of methane for the FID, and isobutylene for the PID. The SapphIRe monitors were zeroed and the monitor's manufacturer-supplied library was used. For the second method, a five-point cyclohexane calibration curve was created for each monitor Comparison of the monitor results of each calibration method (pooled data) indicated a significant difference between methods (t-test, p < 0.001), The SapphIRe group had results closer to the charcoal tubes with the second calibration method, while the PID and FID monitor groups performed better using the first calibration method. The PID monitor group's performance was affected only at the 90% relative humidity (RH) condition. Using the first method, the monitor readings were compared with the charcoal tube average using mixed linear model analyses of variance (ANOVAs) and regression. The ANOVA results showed there was a statistically significant difference among readings from all monitor types (p <0.0001). The regression results demonstrated that the SapphIRe (r(2) = 0.97) and FID (r(2) = 0.92) monitor groups correlated well with the charcoal tubes. The PID monitor group had a similar correlation when 90% RH was excluded (r(2) = 0.94) but had a weaker correlation when it was included (r(2) = 0.58). The operator should take care when using these monitors at high concentrations and the PID monitors at high humidities, consider the variability between units of the same monitor, and conduct performance verification of the monitor being used.
引用
收藏
页码:670 / 680
页数:11
相关论文
共 50 条
  • [21] DESIGN AND PERFORMANCE OF A DIRECT-READING, MULTICHANNEL SPECTROMETER FOR THE DETERMINATION OF CHLORINATED PURGEABLE ORGANIC-COMPOUNDS BY FLAME INFRARED-EMISSION SPECTROMETRY
    KUBALA, SW
    TILOTTA, DC
    BUSCH, MA
    BUSCH, KW
    TALANTA, 1991, 38 (06) : 589 - 602
  • [22] STUDIES ON ORGANIC MICROANALYSIS .8. MODIFIED DIRECT-READING FLOW METER FOR CARBON AND HYDROGEN DETERMINATION
    HOZUMI, K
    IMAEDA, K
    YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 1953, 73 (09): : 907 - 911
  • [23] OBSERVATIONS ON EFFECT OF ORGANIC SOLVENTS IN DIRECT-READING EMISSION-SPECTROMETRIC DETERMINATION OF TRACE ELEMENTS IN RARE-EARTH COMPOUNDS BY ROTATING ELECTRODE
    OSUMI, Y
    KATO, A
    MIYAKE, Y
    ZEITSCHRIFT FUR ANALYTISCHE CHEMIE FRESENIUS, 1970, 251 (01): : 7 - &
  • [24] Effect of working fluids on the performance of a novel direct vapor generation solar organic Rankine cycle system
    Li, Jing
    Alvi, Jahan Zeb
    Pei, Gang
    Ji, Jie
    Li, Pengcheng
    Fu, Huide
    APPLIED THERMAL ENGINEERING, 2016, 98 : 786 - 797
  • [25] Effect of phase change materials on the performance of direct vapor generation solar organic Rankine cycle system
    Alvi, Jahan Zeb
    Feng, Yongqiang
    Wang, Qian
    Imran, Muhammad
    Pei, Gang
    ENERGY, 2021, 223
  • [26] PIENKOWSKY-TYPE CALIBRATION SCHEME FOR 5211SIGMA1 WEIGHT SERIES USING 2 KNIFE-EDGE DIRECT-READING BALANCES
    PEISER, HS
    JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS SECTION C-ENGINEERING AND INSTRUMENTATION, 1964, C 68 (04): : 261 - +
  • [27] A COMPARATIVE STUDY OF BLENDED METALLO-ORGANIC OIL MIXTURES AS CALIBRATING STANDARDS FOR DIRECT-READING EMISSION SPECTROMETRIC DETERMINATION OF METALS IN LUBRICATING OILS
    EVENS, FM
    COWLEY, TG
    TRICE, BC
    APPLIED SPECTROSCOPY, 1969, 23 (06) : 663 - &
  • [28] Effect of Phase Change Material Storage on the Dynamic Performance of a Direct Vapor Generation Solar Organic Rankine Cycle System
    Alvi, Jahan Zeb
    Feng, Yongqiang
    Wang, Qian
    Imran, Muhammad
    Khan, Lehar Asip
    Pei, Gang
    ENERGIES, 2020, 13 (22)
  • [29] Do Environmental Performance and Environmental Management Have a Direct Effect on Firm Value?
    Soedjatmiko, Soedjatmiko
    Tjahjadi, Bambang
    Soewarno, Noorlailie
    JOURNAL OF ASIAN FINANCE ECONOMICS AND BUSINESS, 2021, 8 (01): : 687 - 696
  • [30] Effect of environmental condition on the performance of proton exchange membrane fuel cell
    Wu, Maosheng
    Yu, Datai
    Li, Guo
    Zhang, Yangping
    Beijing Keji Daxue Xuebao/Journal of University of Science and Technology Beijing, 2003, 25 (06): : 584 - 586