Effect of Calibration and Environmental Condition on the Performance of Direct-Reading Organic Vapor Monitors

被引:10
|
作者
Coffey, Christopher [1 ]
LeBouf, Ryan [2 ]
Lee, Larry [3 ]
Slaven, James [3 ]
Martin, Stephen [2 ]
机构
[1] NIOSH, Natl Personal Protect Technol Lab, Morgantown, WV 26505 USA
[2] NIOSH, Div Resp Dis Studies, Morgantown, WV 26505 USA
[3] NIOSH, Hlth Effects Lab Div, Morgantown, WV 26505 USA
关键词
direct-reading organic vapor monitors; flame ionization detector; photoionization detector; SapphIRe; toxic vapor analyzer; IONIZATION GAS-CHROMATOGRAPH; PHOTOIONIZATION DETECTOR; ATMOSPHERES; EXPOSURE;
D O I
10.1080/15459624.2012.725015
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The performance of three MIRAN SapphIRe Portable Infrared Ambient Air Analyzers and three Century Portable Toxic Vapor Analyzers equipped with photoionization (PID) and flame ionization (FID) detectors was compared with charcoal tube sampling. Relationships were investigated using two different calibration methods at four cyclohexane concentrations, three temperatures, and four relative humidities. For the first method, the TVA monitors were calibrated with a single concentration of methane for the FID, and isobutylene for the PID. The SapphIRe monitors were zeroed and the monitor's manufacturer-supplied library was used. For the second method, a five-point cyclohexane calibration curve was created for each monitor Comparison of the monitor results of each calibration method (pooled data) indicated a significant difference between methods (t-test, p < 0.001), The SapphIRe group had results closer to the charcoal tubes with the second calibration method, while the PID and FID monitor groups performed better using the first calibration method. The PID monitor group's performance was affected only at the 90% relative humidity (RH) condition. Using the first method, the monitor readings were compared with the charcoal tube average using mixed linear model analyses of variance (ANOVAs) and regression. The ANOVA results showed there was a statistically significant difference among readings from all monitor types (p <0.0001). The regression results demonstrated that the SapphIRe (r(2) = 0.97) and FID (r(2) = 0.92) monitor groups correlated well with the charcoal tubes. The PID monitor group had a similar correlation when 90% RH was excluded (r(2) = 0.94) but had a weaker correlation when it was included (r(2) = 0.58). The operator should take care when using these monitors at high concentrations and the PID monitors at high humidities, consider the variability between units of the same monitor, and conduct performance verification of the monitor being used.
引用
收藏
页码:670 / 680
页数:11
相关论文
共 50 条
  • [1] Effect of calibration environment on the performance of direct-reading organic vapor monitors
    LeBouf, Ryan F.
    Slaven, James E.
    Coffey, Christopher C.
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2013, 63 (05) : 528 - 533
  • [2] Effect of interferents on the performance of direct-reading organic vapor monitors
    LeBouf, Ryan F.
    Coffey, Christopher C.
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2015, 65 (03) : 261 - 269
  • [3] Performance testing of three portable, direct-reading dust monitors
    Thorpe, A
    Walsh, PT
    ANNALS OF OCCUPATIONAL HYGIENE, 2002, 46 (02): : 197 - 207
  • [4] DIRECT-READING OHMMETER NEEDS NO CALIBRATION
    RAMPRAKASH, V
    ELECTRONICS, 1976, 49 (23): : 115 - 116
  • [6] OPTIMIZING THE PERFORMANCE OF DIRECT-READING DOSIMETERS
    JACKSON, TP
    HEALTH PHYSICS, 1985, 49 (01): : 49 - 54
  • [7] Dealing with the Size-of-Source Effect in the Calibration of Direct-Reading Radiation Thermometers
    Saunders, P.
    TEMPERATURE: ITS MEASUREMENT AND CONTROL IN SCIENCE AND INDUSTRY, VOL 8, 2013, 1552 : 619 - 624
  • [8] COMPARATIVE LABORATORY TRIALS OF 2 PORTABLE DIRECT-READING DUST MONITORS
    CHUNG, KYK
    VAUGHAN, NP
    ANNALS OF OCCUPATIONAL HYGIENE, 1989, 33 (04): : 591 - 606
  • [9] Direct-reading absolute calibration of AC voltage ratio standards
    Callegaro, L
    Bosco, GC
    D'Elia, V
    Serazio, D
    2002 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS, CONFERENCE DIGEST, 2002, : 262 - 263
  • [10] Direct-reading absolute calibration of AC voltage ratio standards
    Callegaro, L
    Bosco, GC
    D'Elia, V
    Serazio, D
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2003, 52 (02) : 380 - 383