Direct and Label-Free Cell Status Monitoring of Spheroids and Microcarriers Using Microfluidic Impedance Cytometry

被引:42
|
作者
Gong, Lingyan [1 ]
Petchakup, Chayakorn [1 ]
Shi, Pujiang [2 ]
Tan, Pei Leng [2 ]
Tan, Lay Poh [2 ]
Tay, Chor Yong [2 ,3 ,4 ,5 ]
Hou, Han Wei [1 ,6 ,7 ]
机构
[1] Nanyang Technol Univ, Sch Mech & Aerosp Engn, 50 Nanyang Ave, Singapore 639798, Singapore
[2] Nanyang Technol Univ, Sch Mat Sci & Engn, 50 Nanyang Ave, Singapore 639798, Singapore
[3] Nanyang Technol Univ, Sch Biol Sci, 60 Nanyang Dr, Singapore 637551, Singapore
[4] Nanyang Environm & Water Res Inst, Environm Chem & Mat Ctr, CleanTech Loop,CleanTech One, Singapore 637141, Singapore
[5] Nanyang Technol Univ Singapore, Energy Res Inst, 50 Nanyang Dr, Singapore 637553, Singapore
[6] Nanyang Technol Univ, Lee Kong Chian Sch Med, 11 Mandalay Rd, Singapore 308232, Singapore
[7] Singapore Massachusetts Inst Technol Alliance Res, Crit Analyt Mfg Personalized Med, 1 CREATE Way,10-01,CREATE Tower, Singapore 138602, Singapore
关键词
biomanufacturing; impedance cytometry; label‐ free; microfluidics; stem cell differentiation; MESENCHYMAL STEM-CELLS; FLOW-CYTOMETRY; SPECTROSCOPY; EXPANSION; MEMBRANE; CULTURE;
D O I
10.1002/smll.202007500
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
3D cellular spheroids/microcarriers (100 mu m-1 mm) are widely used in biomanufacturing, and non-invasive biosensors are useful to monitor cell quality in bioprocesses. In this work, a novel microfluidic approach for label-free and continuous-flow monitoring of single spheroid/microcarrier (hydrogel and Cytodex) based on electrical impedance spectroscopy using co-planar Field's metal electrodes is reported. Through numerical simulation and experimental validation, two unique impedance signatures (|Z(LF)| (60 kHz), |Z(HF)| (1 MHz)) which are optimal for spheroid growth and viability monitoring are identified. Using a closed-loop recirculation system, it is demonstrated that |Z(LF)| increases with breast cancer (MCF-7) spheroid biomass, while higher opacity (impedance ratio |Z(HF)|/|Z(LF)|) indicates cell death due to compromised cell membrane. Anti-cancer drug (paclitaxel)-treated spheroids also exhibit lower |Z(LF)| with increased cell dissociation. Interestingly, impedance characterization of adipose-derived mesenchymal stem cell differentiation on Cytodex microcarriers reveals that adipogenic cells (higher intracellular lipid content) exhibit higher impedance than osteogenic cells (more conductive due to calcium ions) for both microcarriers and single cell level. Taken together, the developed platform offers great versatility for multi-parametric analysis of spheroids/microcarriers at high throughput (approximate to 1 particle/s), and can be readily integrated into bioreactors for long-term and remote monitoring of biomass and cell quality.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Label-free monitoring of cell-based assays: Combining impedance analysis with SPR for multiparametric cell profiling
    Michaelis, S.
    Wegener, J.
    Robelek, R.
    BIOSENSORS & BIOELECTRONICS, 2013, 49 : 63 - 70
  • [42] Towards label-free flow cytometry for automated cell identification using diffuse reflectance spectroscopy
    Watson, Aaron F.
    Haanaes, Nora
    Chambers, Rachel
    Roddan, Alfie
    Sanchez, Elena Monfort
    Runciman, Mark
    Thompson, Alex J.
    BIOPHOTONICS IN POINT-OF-CARE III, 2024, 13008
  • [43] Label-Free Analysis of Red Blood Cell Storage Lesions Using Imaging Flow Cytometry
    Pinto, Ruben N.
    Sebastian, Joseph A.
    Parsons, Michael J.
    Chang, Tim C.
    Turner, Tracey R.
    Acker, Jason P.
    Kolios, Michael C.
    CYTOMETRY PART A, 2019, 95 (09) : 976 - 984
  • [44] Rapid and Accurate Antimicrobial Susceptibility Testing Using Label-Free Electrical Impedance-Based Microfluidic Platform
    Chen, Jiahong
    Zhong, Jianwei
    Chang, Yifu
    Zhou, Yinning
    Koo, Seok Hwee
    Tan, Thean Yen
    Lei, Hongtao
    Ai, Ye
    SMALL, 2024, 20 (06)
  • [45] Label-free electrochemical monitoring of vasopressin in aptamer-based microfluidic biosensors
    He, Peng
    Oncescu, Vlad
    Lee, Seoho
    Choi, Inhee
    Erickson, David
    ANALYTICA CHIMICA ACTA, 2013, 759 : 74 - 80
  • [46] Label-free light scattering microfluidic cytometry using dual-channel 3D hydrodynamic focusing
    Zhang, Shuyu
    Lin, Meiai
    Su, Xuantao
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS IX, 2020, 11190
  • [47] Label-free sperm morphology assessment using imaging flow cytometry
    Vaidyanathan, S.
    Li, A.
    Didion, B. A.
    Friend, S.
    Morrissey, P.
    REPRODUCTION IN DOMESTIC ANIMALS, 2015, 50 : 128 - 128
  • [48] LABEL-FREE MEASUREMENT OF T-CELL ACTIVATION BY MICROFLUIDIC ACOUSTOPHORESIS
    Dabbi, Jayanth M.
    Shi, Yunhua
    Mertiri, Alket
    Christianson, Rebecca J.
    Fiering, Jason
    2021 21ST INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS (TRANSDUCERS), 2021, : 771 - 774
  • [49] Label-free microfluidic cell sorting and detection for rapid blood analysis
    Lu, Nan
    Tay, Hui Min
    Petchakup, Chayakorn
    He, Linwei
    Gong, Lingyan
    Maw, Kay Khine
    Leong, Sheng Yuan
    Lok, Wan Wei
    Ong, Hong Boon
    Guo, Ruya
    Li, King Ho Holden
    Hou, Han Wei
    LAB ON A CHIP, 2023, 23 (05) : 1226 - 1257
  • [50] Apoptotic Bodies in the Pancreatic Tumor Cell Culture Media Enable Label-Free Drug Sensitivity Assessment by Impedance Cytometry
    Honrado, Carlos
    Adair, Sara J.
    Moore, John H.
    Salahi, Armita
    Bauer, Todd W.
    Swami, Nathan S.
    ADVANCED BIOLOGY, 2021, 5 (08):