Towards label-free flow cytometry for automated cell identification using diffuse reflectance spectroscopy

被引:0
|
作者
Watson, Aaron F. [1 ]
Haanaes, Nora [1 ]
Chambers, Rachel [1 ]
Roddan, Alfie [1 ,2 ]
Sanchez, Elena Monfort [1 ,2 ]
Runciman, Mark [1 ,2 ]
Thompson, Alex J. [1 ,2 ]
机构
[1] Imperial Coll London, Inst Global Hlth Innovat, Hamlyn Ctr, London SW7 2AZ, England
[2] Imperial Coll London, St Marys Hosp Campus, Dept Surg & Canc, London W2 1NY, England
来源
关键词
D O I
10.1117/12.3021679
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Flow cytometry is widely used for cell identification and characterization and involves labelling biological and clinical samples with fluorochrome-conjugated antibodies specific to cell markers. This requires use of expensive exogenous reagents and necessitates complex pre-processing of samples. Additionally, extensive challenges arise in clinical samples consisting of highly plastic and heterogenous cell types observed in diseases such as cancer. As such, it is challenging to apply flow cytometry to point-of-care diagnostic applications. To address this issue, we investigated the combination of diffuse reflectance spectroscopy (DRS), microfluidics and machine learning to offer rapid, low-cost, label-free cell identification for potential deployment at the point of care. To achieve this, we utilized a compact fibre-optic diffuse reflectance spectrometer with multi-depth sensing capability. This system was applied to a proof-of-concept cell identification study where we were able to discriminate triple negative breast cancer cells from healthy fibroblasts using commercially available flow channel slides (Ibidi GmbH, channel dimensions: 5 mm width, 0.4 mm height). However, we observed high inter-experimental variability, which was partially attributed to the relatively large fluidic channels. Thus, we investigated in-house fabrication of microfluidics of varying channel widths (0.6-2 mm). To this end, we used a Mars ELEGOO 3D printer and commercially available printing materials to batch fabricate optically and mechanically viable microfluidic chips that were both cheap and customizable. Using these in-house microfluidic devices, we demonstrated DRS-based discrimination of cancer cells of different origins, further indicating the potential of this approach for point-of-care cell identification/characterization. Ultimately, we hope this work will lead to the development of cheap, deployable, and accurate point-of-care tools for rapid, label-free cell identification.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Impedance spectroscopy flow cytometry: Parameters for label-free cell differentiation
    Cheung, K
    Gawad, S
    Renaud, P
    Micro Total Analysis Systems 2004, Vol 1, 2005, (296): : 55 - 57
  • [2] Impedance spectroscopy flow cytometry: On-chip label-free cell differentiation
    Cheung, K
    Gawad, S
    Renaud, P
    CYTOMETRY PART A, 2005, 65A (02) : 124 - 132
  • [3] Label-free intraoperative nerve detection and visualization using ratiometric diffuse reflectance spectroscopy
    Graham A. Throckmorton
    Ezekiel Haugen
    Giju Thomas
    Parker Willmon
    Justin S. Baba
    Carmen C. Solórzano
    Anita Mahadevan-Jansen
    Scientific Reports, 13
  • [4] Label-free intraoperative nerve detection and visualization using ratiometric diffuse reflectance spectroscopy
    Throckmorton, Graham A.
    Haugen, Ezekiel
    Thomas, Giju
    Willmon, Parker
    Baba, Justin S.
    Solorzano, Carmen C.
    Mahadevan-Jansen, Anita
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [5] Diffuse reflectance spectroscopy and Raman spectroscopy for label-free molecular characterization and automated detection of human cartilage and subchondral bone
    Kreiss, Lucas
    Hohmann, Martin
    Klaempfl, Florian
    Schuermann, Sebastian
    Dehghani, Faramarz
    Schmidt, Michael
    Friedrich, Oliver
    Buechler, Lorenz
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 301
  • [7] Label-free flow cytometry-based enzyme inhibitor identification
    Nickelsen, Anna
    Jose, Joachim
    ANALYTICA CHIMICA ACTA, 2021, 1179
  • [8] Absolute sizing and label-free identification of extracellular vesicles by flow cytometry
    van der Pol, Edwin
    de Rond, Leonie
    Coumans, Frank A. W.
    Gool, Elmar L.
    Boing, Anita N.
    Sturk, Auguste
    Nieuwland, Rienk
    van Leeuwen, Ton G.
    NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE, 2018, 14 (03) : 801 - 810
  • [9] Label-free multiphoton imaging flow cytometry
    Kinegawa, Ryo
    Gala de Pablo, Julia
    Wang, Yi
    Hiramatsu, Kotaro
    Goda, Keisuke
    CYTOMETRY PART A, 2023, 103 (07) : 584 - 592
  • [10] Towards automated cancer screening: Label-free classification of fixed cell samples using wavelength modulated Raman spectroscopy
    Woolford, Lana
    Chen, Mingzhou
    Dholakia, Kishan
    Herrington, C. Simon
    JOURNAL OF BIOPHOTONICS, 2018, 11 (04)