Validation of adenosine triphosphate to audit manual cleaning of flexible endoscope channels

被引:90
|
作者
Alfa, Michelle J. [1 ,2 ,3 ]
Fatima, Iram [3 ]
Olson, Nancy [3 ]
机构
[1] Diagnost Serv Manitoba, Clin Microbiol, Winnipeg, MB R2H 2A6, Canada
[2] St Boniface Res Ctr, Microbiol Lab, Winnipeg, MB, Canada
[3] Univ Manitoba, Dept Med Microbiol, Winnipeg, MB, Canada
关键词
Simulated use; Endoscope channel; Cleaning-compliance; Benchmark; Relative light units; DECONTAMINATION; EFFICACY;
D O I
10.1016/j.ajic.2012.03.018
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: Compliance with cleaning of flexible endoscope channels cannot be verified using visual inspection. Adenosine triphosphate (ATP) has been suggested as a possible rapid cleaning monitor for flexible endoscope channels. There have not been published validation studies to specify the level of ATP that indicates inadequate cleaning has been achieved. Objective: The objective of this study was to validate the Clean-Trace (3M Inc, St. Paul, MN) ATP water test method for monitoring manual cleaning of flexible endoscopes. Methods: This was a simulated use study using a duodenoscope as the test device. Artificial test soil containing 10(6) colony-forming units of Pseudomonas aeruginosa and Enterococcus faecalis was used to perfuse all channels. The flush sample method for the suction-biopsy (L1) or air-water channel (L2) using 40 and 20 mLs sterile reverse osmosis water, respectively, was validated. Residuals of ATP, protein, hemoglobin, and bioburden were quantitated from channel samples taken from uncleaned, partially cleaned, and fully cleaned duodenoscopes. The benchmarks for clean were as follows: <6.4 mu g/cm(2) protein, <2.2 mu g/cm(2) hemoglobin, and <4-log(10) colony-forming units/cm(2) bioburden. Results: The average ATP in clean channel samples was 27.7 RLUs and 154 RLUs for L1 and L2, respectively (<200 RLUs for all channels). The average protein, hemoglobin, and bioburden benchmarks were achieved if <200 RLUs were detected. If the channel sample was >200 RLUs, the residual organic and bioburden levels would exceed the acceptable benchmarks. Conclusion: Our data validated that flexible endoscopes that have complete manual cleaning will have <200 RLUs by the Clean-Trace ATP test. Copyright (C) 2013 by the Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:245 / 248
页数:4
相关论文
共 50 条
  • [41] Evaluation of cleaning process efficacy of instruments for robotic surgery using the adenosine triphosphate test
    Dolci, Mariana Ehmke
    Lobo, Renata Desordi
    Nunes, Juliana Almeida
    Acuna, Andrea Alfaya
    Cavassin, Larissa Garms Thimoteo
    Monte, Karine Moretti
    Levin, Anna S.
    Bozola, Fernanda Justo Descio
    Oliveira, Maura Salaroli
    SURGERY, 2023, 174 (02) : 296 - 300
  • [42] Manual cleaning and disinfection of flexible endoscopes - an approach to evaluating a combined procedure
    Knieler, R
    JOURNAL OF HOSPITAL INFECTION, 2001, 48 : S84 - S87
  • [43] Methodological proposal for validation of the disinfecting efficacy of an automated flexible endoscope reprocessor
    Graziano, Kazuko Uchikawa
    Auler Pereira, Marta Elisa
    Koda, Elaine
    REVISTA LATINO-AMERICANA DE ENFERMAGEM, 2016, 24
  • [44] ASSESSMENT OF TEST METHODS FOR EVALUATING EFFECTIVENESS OF MANUAL CLEANING OF FLEXIBLE ENDOSCOPES
    Pietsch, Jennifer
    Washburn, Rebecca
    GASTROENTEROLOGY NURSING, 2017, 40 (02) : 177 - 177
  • [45] Role of adenosine triphosphate-dependent potassium channels in canine penile erection
    Cará, AD
    Fregonesi, A
    Antunes, E
    De Nucci, G
    Netto, NR
    UROLOGY, 2004, 64 (03) : 603 - 607
  • [46] Effects of thiamylal on adenosine triphosphate-sensitive potassium channels during acidosis
    Tsutsumi, Y
    Oshita, S
    Kitahara, H
    Kawano, T
    Yoko, S
    ANESTHESIOLOGY, 2000, 93 (3A) : U169 - U169
  • [47] QUINIDINE BLOCKS ADENOSINE 5'-TRIPHOSPHATE-SENSITIVE POTASSIUM CHANNELS IN HEART
    UNDROVINAS, AI
    BURNASHEV, N
    EROSHENKO, D
    FLEIDERVISH, I
    STARMER, CF
    MAKIELSKI, JC
    ROSENSHTRAUKH, LV
    AMERICAN JOURNAL OF PHYSIOLOGY, 1990, 259 (05): : H1609 - H1612
  • [48] Adenosine-5′-triphosphate opens potassium channels in the forearm vascular bed
    Verkaik, NJ
    Van Ginneken, EEM
    Smits, P
    Rongen, GA
    BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2002, 53 (05) : 545P - 546P
  • [49] A new buildup biofilm model that mimics accumulation of material in flexible endoscope channels
    Luciano, Cristiana da Costa
    Olson, Nancy
    DeGagne, Patricia
    Franca, Rodrigo
    Veiga Tipple, Anaclara Ferreira
    Alfa, Michelle
    JOURNAL OF MICROBIOLOGICAL METHODS, 2016, 127 : 224 - 229
  • [50] Can the adenosine triphosphate (ATP) bioluminescence assay be used as an indicator for hospital cleaning? - A pilot study
    Niephaus, Valerie
    Parohl, Nina
    Heiligtag, Sabine
    Reuter, Henning
    Hackler, Reiner
    Popp, Walter
    GMS HYGIENE AND INFECTION CONTROL, 2024, 19