Validation of adenosine triphosphate to audit manual cleaning of flexible endoscope channels

被引:90
|
作者
Alfa, Michelle J. [1 ,2 ,3 ]
Fatima, Iram [3 ]
Olson, Nancy [3 ]
机构
[1] Diagnost Serv Manitoba, Clin Microbiol, Winnipeg, MB R2H 2A6, Canada
[2] St Boniface Res Ctr, Microbiol Lab, Winnipeg, MB, Canada
[3] Univ Manitoba, Dept Med Microbiol, Winnipeg, MB, Canada
关键词
Simulated use; Endoscope channel; Cleaning-compliance; Benchmark; Relative light units; DECONTAMINATION; EFFICACY;
D O I
10.1016/j.ajic.2012.03.018
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: Compliance with cleaning of flexible endoscope channels cannot be verified using visual inspection. Adenosine triphosphate (ATP) has been suggested as a possible rapid cleaning monitor for flexible endoscope channels. There have not been published validation studies to specify the level of ATP that indicates inadequate cleaning has been achieved. Objective: The objective of this study was to validate the Clean-Trace (3M Inc, St. Paul, MN) ATP water test method for monitoring manual cleaning of flexible endoscopes. Methods: This was a simulated use study using a duodenoscope as the test device. Artificial test soil containing 10(6) colony-forming units of Pseudomonas aeruginosa and Enterococcus faecalis was used to perfuse all channels. The flush sample method for the suction-biopsy (L1) or air-water channel (L2) using 40 and 20 mLs sterile reverse osmosis water, respectively, was validated. Residuals of ATP, protein, hemoglobin, and bioburden were quantitated from channel samples taken from uncleaned, partially cleaned, and fully cleaned duodenoscopes. The benchmarks for clean were as follows: <6.4 mu g/cm(2) protein, <2.2 mu g/cm(2) hemoglobin, and <4-log(10) colony-forming units/cm(2) bioburden. Results: The average ATP in clean channel samples was 27.7 RLUs and 154 RLUs for L1 and L2, respectively (<200 RLUs for all channels). The average protein, hemoglobin, and bioburden benchmarks were achieved if <200 RLUs were detected. If the channel sample was >200 RLUs, the residual organic and bioburden levels would exceed the acceptable benchmarks. Conclusion: Our data validated that flexible endoscopes that have complete manual cleaning will have <200 RLUs by the Clean-Trace ATP test. Copyright (C) 2013 by the Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:245 / 248
页数:4
相关论文
共 50 条
  • [1] The adenosine triphosphate test is a rapid and reliable audit tool to assess manual cleaning adequacy of flexible endoscope channels
    Alfa, Michelle J.
    Fatima, Iram
    Olson, Nancy
    AMERICAN JOURNAL OF INFECTION CONTROL, 2013, 41 (03) : 249 - 253
  • [2] Development and validation of rapid use scope test strips to determine the efficacy of manual cleaning for flexible endoscope channels
    Alfa, Michelle J.
    Olson, Nancy
    DeGagne, Pat
    Simner, Patricia J.
    AMERICAN JOURNAL OF INFECTION CONTROL, 2012, 40 (09) : 860 - 865
  • [3] Effectiveness of adenosine triphosphate to monitor manual cleaning and disinfection efficacy of flexible endoscopes in Hong Kong
    Chan, Ada S. F.
    Chan, Henry L. Y.
    Yan, Bruno K. L.
    Lai, Mooris K. C.
    JGH OPEN, 2023, 7 (02): : 141 - 147
  • [4] Simulated-use validation of a sponge ATP method for determining the adequacy of manual cleaning of endoscope channels
    Alfa M.J.
    Olson N.
    BMC Research Notes, 9 (1)
  • [5] ADENOSINE TRIPHOSPHATE (ATP) EVALUATION OF MANUAL CLEANING FOR ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY SCOPES
    Lucht, Katherine
    Oliver, Bill
    Przybylski, Elizabeth
    GASTROENTEROLOGY NURSING, 2017, 40 (02) : 175 - 175
  • [6] Use of adenosine triphosphate to audit reprocessing of flexible endoscopes with an elevator mechanism
    Quan, Erik
    Mahmood, Rizwan
    Naik, Amar
    Sargon, Peter
    Shastri, Nikhil
    Venu, Mukund
    Parada, Jorge P.
    Gupta, Neil
    AMERICAN JOURNAL OF INFECTION CONTROL, 2018, 46 (11) : 1272 - 1277
  • [7] Use of Adenosine Triphosphate to Audit Reprocessing of Flexible Endoscopes With an Elevator Mechanism
    Quan, Erik
    Parada, Jorge
    Shastri, Nikhil
    Naik, Amar S.
    Venu, Mukund
    Gupta, Neil
    GASTROINTESTINAL ENDOSCOPY, 2017, 85 (05) : AB165 - AB166
  • [8] Adenosine Triphosphate Testing As a Rapid Surveillance Tool for Assessing the Adequacy of Manual Cleaning of Flexible Endoscopes Prior to High Level Disinfection
    Sethi, Saurabh
    Friedland, Shai
    Banerjee, Subhas
    GASTROINTESTINAL ENDOSCOPY, 2015, 81 (05) : AB232 - AB233
  • [9] The potential benefits of an automated flexible endoscope channel brushing system for manual cleaning of endoscopes
    van der Ploeg, Koen
    Bruno, Marco J.
    ENDOSCOPY, 2023, 55 (07) : 643 - 644
  • [10] The validity of adenosine triphosphate measurement in detecting endoscope contamination
    Mccafferty, C. E.
    Micali, G. T.
    Aghajani, M. J.
    Lockart, I. G.
    Abi-Hanna, D.
    Vickery, K.
    Jensen, S. O.
    Gosbell, I. B.
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2017, 32 : 25 - 25