Development of real-time motion verification system using in-room optical images for respiratory-gated radiotherapy

被引:6
|
作者
Park, Yang-Kyun [1 ,2 ]
Son, Tae-geun [3 ]
Kim, Hwiyoung [2 ]
Lee, Jaegi [4 ]
Sung, Wonmo [2 ]
Kim, Il Han [1 ,2 ]
Lee, Kunwoo [3 ]
Bang, Young-bong [5 ]
Ye, Sung-Joon [1 ,2 ,4 ,5 ]
机构
[1] Seoul Natl Univ Hosp, Dept Radiat Oncol, Seoul 110744, South Korea
[2] Seoul Natl Univ, Interdisciplinary Program Radiat Appl Life Sci, Seoul, South Korea
[3] Seoul Natl Univ, Dept Mech & Aerosp Engn, Seoul, South Korea
[4] Seoul Natl Univ, Program Biomed Radiat Sci, Grad Sch Convergence Sci & Technol, Dept Transdisciplinary Studies, Seoul, South Korea
[5] Seoul Natl Univ, Adv Inst Convergence Technol, Suwon, South Korea
来源
基金
新加坡国家研究基金会;
关键词
gated radiotherapy; external marker tracking; quality assurance; 4D CT; AUDIOVISUAL BIOFEEDBACK; TUMOR MOTION; BREATH-HOLD; PATIENT SURFACE; LIVER-TUMORS; DISPLACEMENT; CT; MANAGEMENT; ACCURACY; MOVEMENT;
D O I
10.1120/jacmp.v14i5.4245
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Phase-based respiratory-gated radiotherapy relies on the reproducibility of patient breathing during the treatment. To monitor the positional reproducibility of patient breathing against a 4D CT simulation, we developed a real-time motion verification system (RMVS) using an optical tracking technology. The system in the treatment room was integrated with a real-time position management system. To test the system, an anthropomorphic phantom that was mounted on a motion platform moved on a programmed breathing pattern and then underwent a 4D CT simulation with RPM. The phase-resolved anterior surface lines were extracted from the 4D CT data to constitute 4D reference lines. In the treatment room, three infrared reflective markers were attached on the superior, middle, and inferior parts of the phantom along with the body midline and then RMVS could track those markers using an optical camera system. The real-time phase information extracted from RPM was delivered to RMVS via in-house network software. Thus, the real-time anterior-posterior positions of the markers were simultaneously compared with the 4D reference lines. The technical feasibility of RMVS was evaluated by repeating the above procedure under several scenarios such as ideal case (with identical motion parameters between simulation and treatment), cycle change, baseline shift, displacement change, and breathing type changes (abdominal or chest breathing). The system capability for operating under irregular breathing was also investigated using real patient data. The evaluation results showed that RMVS has a competence to detect phase-matching errors between patient's motion during the treatment and 4D CT simulation. Thus, we concluded that RMVS could be used as an online quality assurance tool for phase-based gating treatments.
引用
收藏
页码:25 / 42
页数:18
相关论文
共 50 条
  • [41] Physical aspects of a real-time tumor-tracking system for gated radiotherapy
    Shirato, H
    Shimizu, S
    Kunieda, T
    Kitamura, K
    van Herk, M
    Kagei, K
    Nishioka, T
    Hashimoto, S
    Fujita, K
    Aoyama, H
    Tsuchiya, K
    Kudo, K
    Miyasaka, K
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (04): : 1187 - 1195
  • [42] A Prototype of a Real-Time Respiratory Motion Monitoring System Using Microsoft Kinect Sensor
    Xia, J.
    MEDICAL PHYSICS, 2012, 39 (06) : 3689 - 3689
  • [43] Development of a Gated Frameless Stereotactic Radiosurgery/Radiotherapy System with Real-time 3D Position Monitoring and Adaptive Head Motion Compensation
    Wen, Z.
    Yenice, K. M.
    Farrey, K.
    Wiersma, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S118 - S119
  • [44] Development of Real-Time Time Gated Digital (TGD) OFDR Method and Its Performance Verification
    Kishida, Kinzo
    Guzik, Artur
    Nishiguchi, Ken'ichi
    Li, Che-Hsien
    Azuma, Daiji
    Liu, Qingwen
    He, Zuyuan
    SENSORS, 2021, 21 (14)
  • [45] Changes in the distance between an internal fiducial marker and a motion tumor on fluoroscopic real-time tumor-tracking system evaluated with an in-room CT system
    Taguchi, K.
    Ebe, K.
    Hiyama, A.
    Tsukamoto, K.
    Sasai, H.
    Nakashima, Y.
    Yamatogi, S.
    Kanzaki, R.
    Matsumoto, T.
    Matsunaga, N.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S612 - S612
  • [46] Development of A Real-Time Nudity Censorship System on Images
    Dewantono, Satrio
    Supriana, Iping
    2014 2ND INTERNATIONAL CONFERENCE ON INFORMATION AND COMMUNICATION TECHNOLOGY (ICOICT), 2014,
  • [47] Real-time and precise monitoring of the breast motion during irradiation using real-time tumor-tracking radiotherapy (RTRT) system
    Kinoshita, R.
    Shimizu, S.
    Katoh, N.
    Onimaru, R.
    Shirato, H.
    Miyasaka, K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S608 - S608
  • [48] Correlation of target movement, diaphragm motion and external sensor signals for respiratory-gated hepatoma radiotherapy using TACE as a target indicator
    Lee, C
    Hong, J
    Ho, C
    Chao, T
    MEDICAL PHYSICS, 2005, 32 (06) : 1945 - 1945
  • [49] Real-time dosimetry in radiotherapy using tailored optical fibers
    Rahman, A. K. M. Mizanur
    Zubair, H. T.
    Begum, Mahfuza
    Abdul-Rashid, H. A.
    Yusoff, Z.
    Omar, Nasr Y. M.
    Ung, N. M.
    Mat-Sharif, K. A.
    Bradley, D. A.
    RADIATION PHYSICS AND CHEMISTRY, 2016, 122 : 43 - 47
  • [50] Ensemble framework based real-time respiratory motion prediction for adaptive radiotherapy applications
    Tatinati, Sivanagaraja
    Nazarpour, Kianoush
    Ang, Wei Tech
    Veluvolu, Kalyana C.
    MEDICAL ENGINEERING & PHYSICS, 2016, 38 (08) : 749 - 757