Development of real-time motion verification system using in-room optical images for respiratory-gated radiotherapy

被引:6
|
作者
Park, Yang-Kyun [1 ,2 ]
Son, Tae-geun [3 ]
Kim, Hwiyoung [2 ]
Lee, Jaegi [4 ]
Sung, Wonmo [2 ]
Kim, Il Han [1 ,2 ]
Lee, Kunwoo [3 ]
Bang, Young-bong [5 ]
Ye, Sung-Joon [1 ,2 ,4 ,5 ]
机构
[1] Seoul Natl Univ Hosp, Dept Radiat Oncol, Seoul 110744, South Korea
[2] Seoul Natl Univ, Interdisciplinary Program Radiat Appl Life Sci, Seoul, South Korea
[3] Seoul Natl Univ, Dept Mech & Aerosp Engn, Seoul, South Korea
[4] Seoul Natl Univ, Program Biomed Radiat Sci, Grad Sch Convergence Sci & Technol, Dept Transdisciplinary Studies, Seoul, South Korea
[5] Seoul Natl Univ, Adv Inst Convergence Technol, Suwon, South Korea
来源
基金
新加坡国家研究基金会;
关键词
gated radiotherapy; external marker tracking; quality assurance; 4D CT; AUDIOVISUAL BIOFEEDBACK; TUMOR MOTION; BREATH-HOLD; PATIENT SURFACE; LIVER-TUMORS; DISPLACEMENT; CT; MANAGEMENT; ACCURACY; MOVEMENT;
D O I
10.1120/jacmp.v14i5.4245
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Phase-based respiratory-gated radiotherapy relies on the reproducibility of patient breathing during the treatment. To monitor the positional reproducibility of patient breathing against a 4D CT simulation, we developed a real-time motion verification system (RMVS) using an optical tracking technology. The system in the treatment room was integrated with a real-time position management system. To test the system, an anthropomorphic phantom that was mounted on a motion platform moved on a programmed breathing pattern and then underwent a 4D CT simulation with RPM. The phase-resolved anterior surface lines were extracted from the 4D CT data to constitute 4D reference lines. In the treatment room, three infrared reflective markers were attached on the superior, middle, and inferior parts of the phantom along with the body midline and then RMVS could track those markers using an optical camera system. The real-time phase information extracted from RPM was delivered to RMVS via in-house network software. Thus, the real-time anterior-posterior positions of the markers were simultaneously compared with the 4D reference lines. The technical feasibility of RMVS was evaluated by repeating the above procedure under several scenarios such as ideal case (with identical motion parameters between simulation and treatment), cycle change, baseline shift, displacement change, and breathing type changes (abdominal or chest breathing). The system capability for operating under irregular breathing was also investigated using real patient data. The evaluation results showed that RMVS has a competence to detect phase-matching errors between patient's motion during the treatment and 4D CT simulation. Thus, we concluded that RMVS could be used as an online quality assurance tool for phase-based gating treatments.
引用
收藏
页码:25 / 42
页数:18
相关论文
共 50 条
  • [21] Statistical Determination of the Gating Windows for Respiratory-Gated Radiotherapy Using a Visible Guiding System
    Oh, Se An
    Yea, Ji Woon
    Kim, Sung Kyu
    PLOS ONE, 2016, 11 (05):
  • [22] Estimation of patient-specific imaging dose for real-time tumour monitoring in lung patients during respiratory-gated radiotherapy
    Shiinoki, Takehiro
    Onizuka, Ryota
    Kawahara, Daisuke
    Suzuki, Tatsuhiko
    Yuasa, Yuki
    Fujimoto, Koya
    Uehara, Takuya
    Hanazawa, Hideki
    Shibuya, Keiko
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (06):
  • [23] Predicting respiratory motion for real-time tumour tracking in radiotherapy
    Krilavicius, Tomas
    Zliobaite, Indre
    Simonavicius, Henrikas
    Jarusevicius, Laimonas
    2016 IEEE 29TH INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS (CBMS), 2016, : 7 - 12
  • [24] Template-Less Real-Time Robust Marker Tracking for Respiratory-Gated Radiation Therapy
    Taguchi, Y.
    Hirai, R.
    Sakata, Y.
    Mori, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E651 - E652
  • [25] Real-time intrafraction motion in breast radiotherapy using an optical surface scanner
    Reitz, D.
    Schoenecker, S.
    Freislederer, P.
    Pazos, M.
    Niyazi, M.
    Ganswindt, U.
    Belka, C.
    Corradini, S.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S642 - S643
  • [26] Real-time monitoring of radiofrequency ablation of rabbit liver by respiratory-gated quantitative temperature MRI
    Lepetit-Coiffe, Matthieu
    Quesson, Bruno
    Seror, Olivier
    Dumont, Erik
    Le Bail, Brigitte
    Moonen, Chrit T. W.
    Trillaud, Herve
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (01) : 152 - 159
  • [27] Motion correction of respiratory-gated PET images using deep learning based image registration framework
    Li, Tiantian
    Zhang, Mengxi
    Qi, Wenyuan
    Asma, Evren
    Qi, Jinyi
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (15):
  • [28] Development of An Applicator for Treating Shallow and Moving Tumors with Respiratory-Gated Spot-Scanning Proton Therapy Using Real-Time Image Guidance
    Matsuura, T.
    Fujii, Y.
    Takao, S.
    Yamada, T.
    Matsuzaki, Y.
    Miyamoto, N.
    Takayanagi, T.
    Fujitaka, S.
    Shimizu, S.
    Shirato, H.
    Umegaki, K.
    MEDICAL PHYSICS, 2015, 42 (06) : 3207 - 3208
  • [29] Real-Time Prediction of Respiratory Motion Traces For Radiotherapy with Ensemble learning
    Tatinati, Sivanagaraja
    Veluvolu, Kalyana C.
    Hong, Sun-Mog
    Nazarpour, Kianoush
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 4204 - 4207
  • [30] A real-time respiratory motion monitoring system using KINECT: Proof of concept
    Xia, Junyi
    Siochi, R. Alfredo
    MEDICAL PHYSICS, 2012, 39 (05) : 2682 - 2685