Development of real-time motion verification system using in-room optical images for respiratory-gated radiotherapy

被引:6
|
作者
Park, Yang-Kyun [1 ,2 ]
Son, Tae-geun [3 ]
Kim, Hwiyoung [2 ]
Lee, Jaegi [4 ]
Sung, Wonmo [2 ]
Kim, Il Han [1 ,2 ]
Lee, Kunwoo [3 ]
Bang, Young-bong [5 ]
Ye, Sung-Joon [1 ,2 ,4 ,5 ]
机构
[1] Seoul Natl Univ Hosp, Dept Radiat Oncol, Seoul 110744, South Korea
[2] Seoul Natl Univ, Interdisciplinary Program Radiat Appl Life Sci, Seoul, South Korea
[3] Seoul Natl Univ, Dept Mech & Aerosp Engn, Seoul, South Korea
[4] Seoul Natl Univ, Program Biomed Radiat Sci, Grad Sch Convergence Sci & Technol, Dept Transdisciplinary Studies, Seoul, South Korea
[5] Seoul Natl Univ, Adv Inst Convergence Technol, Suwon, South Korea
来源
基金
新加坡国家研究基金会;
关键词
gated radiotherapy; external marker tracking; quality assurance; 4D CT; AUDIOVISUAL BIOFEEDBACK; TUMOR MOTION; BREATH-HOLD; PATIENT SURFACE; LIVER-TUMORS; DISPLACEMENT; CT; MANAGEMENT; ACCURACY; MOVEMENT;
D O I
10.1120/jacmp.v14i5.4245
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Phase-based respiratory-gated radiotherapy relies on the reproducibility of patient breathing during the treatment. To monitor the positional reproducibility of patient breathing against a 4D CT simulation, we developed a real-time motion verification system (RMVS) using an optical tracking technology. The system in the treatment room was integrated with a real-time position management system. To test the system, an anthropomorphic phantom that was mounted on a motion platform moved on a programmed breathing pattern and then underwent a 4D CT simulation with RPM. The phase-resolved anterior surface lines were extracted from the 4D CT data to constitute 4D reference lines. In the treatment room, three infrared reflective markers were attached on the superior, middle, and inferior parts of the phantom along with the body midline and then RMVS could track those markers using an optical camera system. The real-time phase information extracted from RPM was delivered to RMVS via in-house network software. Thus, the real-time anterior-posterior positions of the markers were simultaneously compared with the 4D reference lines. The technical feasibility of RMVS was evaluated by repeating the above procedure under several scenarios such as ideal case (with identical motion parameters between simulation and treatment), cycle change, baseline shift, displacement change, and breathing type changes (abdominal or chest breathing). The system capability for operating under irregular breathing was also investigated using real patient data. The evaluation results showed that RMVS has a competence to detect phase-matching errors between patient's motion during the treatment and 4D CT simulation. Thus, we concluded that RMVS could be used as an online quality assurance tool for phase-based gating treatments.
引用
收藏
页码:25 / 42
页数:18
相关论文
共 50 条
  • [31] Real time radiotherapy verification with Cherenkov imaging: development of a system for beamlet verification
    Pogue, B. W.
    Krishnaswamy, V.
    Jermyn, M.
    Bruza, P.
    Miao, T.
    Ware, William
    Saunders, S. L.
    Andreozzi, J. M.
    Gladstone, D. J.
    Jarvis, L. A.
    9TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, 2017, 847
  • [32] Evaluation of internal lung motion for respiratory-gated radiotherapy using MRI: Part I - Correlating internal lung motion with skin fiducial motion
    Koch, N
    Liu, HH
    Starkschall, G
    Jacobson, M
    Forster, K
    Liao, ZX
    Komaki, R
    Stevens, CW
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (05): : 1459 - 1472
  • [33] Accuracy of real-time respiratory motion tracking and time delay of gating radiotherapy based on optical surface imaging technique
    Li Chen
    Sen Bai
    Guangjun Li
    Zhibin Li
    Qing Xiao
    Long Bai
    Changhu Li
    Lixun Xian
    Zhenyao Hu
    Guyu Dai
    Guangyu Wang
    Radiation Oncology, 15
  • [34] Accuracy of real-time respiratory motion tracking and time delay of gating radiotherapy based on optical surface imaging technique
    Chen, Li
    Bar, Sen
    Li, Guangjun
    Li, Zhibin
    Xiao, Qing
    Bai, Long
    Li, Changhu
    Xian, Lixun
    Hu, Zhenyao
    Dai, Guyu
    Wang, Guangyu
    RADIATION ONCOLOGY, 2020, 15 (01)
  • [35] Analysis of the optimum internal margin for respiratory-gated radiotherapy using end-exhalation phase assessments using a motion phantom
    Yaegashi, Yuji
    Tateoka, Kunihiko
    Nakazawa, Takuya
    Fujimoto, Kazunori
    Shima, Katsumi
    Suzuki, Junji
    Nakata, Akihiro
    Saito, Yuichi
    Abe, Tadanori
    Sakata, Koichi
    Hareyama, Masato
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (02): : 81 - 91
  • [36] Time-resolved dosimetric verification of respiratory-gated radiotherapy exposures using a high-resolution 2D ionisation chamber array
    King, R. B.
    Agnew, C. E.
    O'Connell, B. F.
    Prise, K. M.
    Hounsell, A. R.
    McGarry, C. K.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (15): : 5529 - 5546
  • [37] Modeling internal respiratory motion for real-time targeting of lung tumors in radiotherapy
    Kyriakou, E.
    McKenzie, R.
    Suchowerska, N.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S75 - S75
  • [38] Prediction of respiratory tumour motion for real-time image-guided radiotherapy
    Sharp, GC
    Jiang, SB
    Shimizu, S
    Shirato, H
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (03): : 425 - 440
  • [39] Development of a Real-Time Optical Tracking Goggle System (OTGS) for Intracranial Stereotactic Radiotherapy
    Mittauer, K.
    Yan, G.
    Lu, B.
    Barraclough, B.
    Li, J.
    Liu, C.
    MEDICAL PHYSICS, 2014, 41 (06) : 519 - 520
  • [40] Real-Time Motion Compensation Using Optical Flow
    Benes, Radek
    Riha, Kamil
    TSP 2010: 33RD INTERNATIONAL CONFERENCE ON TELECOMMUNICATIONS AND SIGNAL PROCESSING, 2010, : 166 - 170