Vascular centerline extraction in 3D MR angiograms for phase contrast MRI blood flow measurement

被引:17
|
作者
Hoyos, Marcela Hernandez [1 ,3 ]
Orlowski, Piotr [2 ]
Piatkowska-Janko, Ewa [2 ]
Bogorodzki, Piotr [2 ]
Orkisz, Maciej [1 ]
机构
[1] Inst Natl Sci Appl, CREATIS, CNRS 5515, F-69621 Villeurbanne, France
[2] Warsaw Univ Technol, Fac Elect & Telecommun, Inst Radioelect, ZEJM BINSK, PL-00665 Warsaw, Poland
[3] Univ Los Andes, Grp Ingn Biomed, Grp Imagine, Bogota, DC, Colombia
关键词
Computer-assisted Image Analysis; MRI angiography; Three-dimensional image; Carotid arteries; Vertebral arteries;
D O I
10.1007/s11548-006-0005-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The accuracy of 2D phase contrast (PC) magnetic resonance angiography (MRA) depends on the alignment between the vessels and the imaging plane. PC MRA imaging of blood flow is challenging when the flow in several vessels is to be evaluated with one acquisition. For this purpose, semiautomatic determination of the plane most perpendicular to several vessels is proposed based on centerlines extracted from 3D MRA. Arterial centerlines are extracted from 3D MRA based on iterative estimation-prediction, multi-scale analysis of image moments, and a second-order shape model. The optimal plane is determined by minimizing misalignment between its normal vector and the centerlines' tangent vectors. The method was evaluated on a phantom and on 35 patients, by seeking the optimal plane for cerebral blood flow quantification simultaneously in internal carotids and vertebral arteries. In the phantom, difference of orientation and of height between known and calculated planes was 1.2 degrees and 2.5mm, respectively. In the patients, all but one centerline were correctly extracted and the misalignment of the plane was within 12 degrees per artery. Semi-automatic centerline extraction simplifies and automates determination of the plane orthogonal to one vessel, thereby permitting automatic simultaneous minimization of the misalignment with several vessels in PC MRA.
引用
收藏
页码:51 / 61
页数:11
相关论文
共 50 条
  • [41] QUANTITATIVE FLOW MEASUREMENT IN PHASE-CONTRAST MR ANGIOGRAPHY
    WALKER, MF
    SOUZA, SP
    DUMOULIN, CL
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (02) : 304 - 313
  • [42] A novel robust tube detection filter for 3D centerline extraction
    Pock, T
    Beichel, R
    Bischof, H
    IMAGE ANALYSIS, PROCEEDINGS, 2005, 3540 : 481 - 490
  • [43] Determination of carotid artery stenosis by blood flow measurement using ungated 2D-phase contrast MR angiography
    Buijs, PC
    Bakker, CJ
    Mali, WP
    RADIOLOGY, 1997, 205 : 1130 - 1130
  • [44] 3D actin network centerline extraction with multiple active contours
    Xu, Ting
    Vavylonis, Dimitrios
    Huang, Xiaolei
    MEDICAL IMAGE ANALYSIS, 2014, 18 (02) : 272 - 284
  • [45] FLAIR vascular hyperintensities and 4D MR angiograms for the estimation of collateral blood flow in anterior cerebral artery ischemia
    Gawlitza, Matthias
    Boehme, Johannes
    Maros, Mate
    Lobsien, Donald
    Michalski, Dominik
    Groden, Christoph
    Hoffmann, Karl-Titus
    Foerster, Alex
    PLOS ONE, 2017, 12 (02):
  • [46] Recurrent varicocele - Demonstration by 3D phase-contrast MR angiography
    vonHeijne, A
    ACTA RADIOLOGICA, 1997, 38 (06) : 1020 - 1022
  • [47] Rapid measurement of renal artery blood flow with ungated spiral phase-contrast MRI
    Park, JB
    Santos, JM
    Hargreaves, BA
    Nayak, KS
    Sommer, G
    Hu, BS
    Nishimura, DG
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (05) : 590 - 595
  • [48] Particle trace visualization of intracardiac flow using time-resolved 3D phase contrast MRI
    Wigström, L
    Ebbers, T
    Fyrenius, A
    Karlsson, M
    Engvall, J
    Wranne, B
    Bolger, AF
    MAGNETIC RESONANCE IN MEDICINE, 1999, 41 (04) : 793 - 799
  • [49] Flow inside a bone scaffold: Visualization using 3D phase contrast MRI and comparison with numerical simulations
    Han, Suyue
    Currier, Todd
    Edraki, Mahdiar
    Liu, Boyuan
    Lynch, Maureen E.
    Modarres-Sadeghi, Yahya
    JOURNAL OF BIOMECHANICS, 2021, 126
  • [50] Contrast enhanced computerized tomography measurement of vascular blood flow
    Sixou, B.
    Boissel, L.
    Sigovan, M.
    6TH INTERNATIONAL WORKSHOP ON NEW COMPUTATIONAL METHODS FOR INVERSE PROBLEMS, 2016, 756