摘要
The accuracy of 2D phase contrast (PC) magnetic resonance angiography (MRA) depends on the alignment between the vessels and the imaging plane. PC MRA imaging of blood flow is challenging when the flow in several vessels is to be evaluated with one acquisition. For this purpose, semiautomatic determination of the plane most perpendicular to several vessels is proposed based on centerlines extracted from 3D MRA. Arterial centerlines are extracted from 3D MRA based on iterative estimation-prediction, multi-scale analysis of image moments, and a second-order shape model. The optimal plane is determined by minimizing misalignment between its normal vector and the centerlines' tangent vectors. The method was evaluated on a phantom and on 35 patients, by seeking the optimal plane for cerebral blood flow quantification simultaneously in internal carotids and vertebral arteries. In the phantom, difference of orientation and of height between known and calculated planes was 1.2 degrees and 2.5mm, respectively. In the patients, all but one centerline were correctly extracted and the misalignment of the plane was within 12 degrees per artery. Semi-automatic centerline extraction simplifies and automates determination of the plane orthogonal to one vessel, thereby permitting automatic simultaneous minimization of the misalignment with several vessels in PC MRA.
引用
收藏
页码:51 / 61
页数:11
相关论文
共 50 条
  • [31] 3D phase contrast EPI MR angiography of the carotid arteries
    Debatin, J.F., 1600, Lippincott Williams and Wilkins (19):
  • [32] Semiautomatic segmentation of 3D contrast-enhanced MR and stenosis quantification angiograms of the internal carotid artery
    van Bemmel, CM
    Viergever, MA
    Niessen, WJ
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (04) : 753 - 760
  • [33] Blood Flow Measurement with Phase Contrast MRI According to Flip Angle in the Ascending Aorta
    Kim, Moon Sun
    Kweon, Dae Cheol
    JOURNAL OF THE KOREAN MAGNETICS SOCIETY, 2016, 26 (04): : 142 - 148
  • [34] Effect of 3D flow disturbances on MR angiography as studied with 3D computer simulation of blood flow
    Ortega, HV
    Mohamed, FB
    Godo, M
    Vinitski, S
    Iwanaga, T
    Tartaglino, LM
    RADIOLOGY, 1996, 201 : 355 - 355
  • [35] Volume tracking – a novel method for visualization and quantification of intracardiac blood flow from 3D time resolved phase contrast MRI
    Johannes Töger
    Martin Ugander
    Håkan Arheden
    Einar Heiberg
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [36] Flow visualization of recurrent aneurysms after coil embolization by 3D phase-contrast MRI
    Kenichi Kono
    Tomoaki Terada
    Acta Neurochirurgica, 2014, 156 : 2035 - 2040
  • [37] Flow visualization of recurrent aneurysms after coil embolization by 3D phase-contrast MRI
    Kono, Kenichi
    Terada, Tomoaki
    ACTA NEUROCHIRURGICA, 2014, 156 (11) : 2035 - 2040
  • [38] Fully Automatic 3D Glioma Extraction in Multi-contrast MRI
    Dvorak, Pavel
    Bartusek, Karel
    IMAGE ANALYSIS AND RECOGNITION, ICIAR 2014, PT II, 2014, 8815 : 239 - 246
  • [39] 3D pulmonary perfusion MRI and MR angiography of pulmonary embolism in pigs after a single injection of a blood pool MR contrast agent
    Christian Fink
    Sebastian Ley
    Michael Puderbach
    Christian Plathow
    Michael Bock
    Hans-Ulrich Kauczor
    European Radiology, 2004, 14 : 1291 - 1296
  • [40] 3D pulmonary perfusion MRI and MR angiography of pulmonary embolism in pigs after a single injection of a blood pool MR contrast agent
    Fink, C
    Ley, S
    Puderbach, M
    Plathow, C
    Bock, M
    Kauczor, HU
    EUROPEAN RADIOLOGY, 2004, 14 (07) : 1291 - 1296