Vascular centerline extraction in 3D MR angiograms for phase contrast MRI blood flow measurement

被引:17
|
作者
Hoyos, Marcela Hernandez [1 ,3 ]
Orlowski, Piotr [2 ]
Piatkowska-Janko, Ewa [2 ]
Bogorodzki, Piotr [2 ]
Orkisz, Maciej [1 ]
机构
[1] Inst Natl Sci Appl, CREATIS, CNRS 5515, F-69621 Villeurbanne, France
[2] Warsaw Univ Technol, Fac Elect & Telecommun, Inst Radioelect, ZEJM BINSK, PL-00665 Warsaw, Poland
[3] Univ Los Andes, Grp Ingn Biomed, Grp Imagine, Bogota, DC, Colombia
关键词
Computer-assisted Image Analysis; MRI angiography; Three-dimensional image; Carotid arteries; Vertebral arteries;
D O I
10.1007/s11548-006-0005-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The accuracy of 2D phase contrast (PC) magnetic resonance angiography (MRA) depends on the alignment between the vessels and the imaging plane. PC MRA imaging of blood flow is challenging when the flow in several vessels is to be evaluated with one acquisition. For this purpose, semiautomatic determination of the plane most perpendicular to several vessels is proposed based on centerlines extracted from 3D MRA. Arterial centerlines are extracted from 3D MRA based on iterative estimation-prediction, multi-scale analysis of image moments, and a second-order shape model. The optimal plane is determined by minimizing misalignment between its normal vector and the centerlines' tangent vectors. The method was evaluated on a phantom and on 35 patients, by seeking the optimal plane for cerebral blood flow quantification simultaneously in internal carotids and vertebral arteries. In the phantom, difference of orientation and of height between known and calculated planes was 1.2 degrees and 2.5mm, respectively. In the patients, all but one centerline were correctly extracted and the misalignment of the plane was within 12 degrees per artery. Semi-automatic centerline extraction simplifies and automates determination of the plane orthogonal to one vessel, thereby permitting automatic simultaneous minimization of the misalignment with several vessels in PC MRA.
引用
收藏
页码:51 / 61
页数:11
相关论文
共 50 条
  • [21] Automatic centerline extraction for 3D virtual bronchoscopy
    Law, TY
    Heng, PA
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2000, 2000, 1935 : 786 - 795
  • [22] Real-time imaging and triggering of 3D contrast-enhanced MR angiograms using MR fluoroscopy
    Stephen J. Riederer
    Sean B. Fain
    David G. Kruger
    Reed F. Busse
    Magnetic Resonance Materials in Physics, Biology and Medicine, 1999, 8 (3) : 196 - 206
  • [23] 3D vascular analysis from biplane angiograms
    Hoffmann, KR
    Sen, A
    Lan, L
    Williams, BB
    Chua, KG
    Doi, K
    RADIOLOGY, 1997, 205 : 1414 - 1414
  • [24] Intracranial vascular stenosis and occlusion: comparison of 3D time-of-flight and 3D phase-contrast MR angiography
    Oelerich, M
    Lentschig, MG
    Zunker, P
    Reimer, P
    Rummeny, EJ
    Schuierer, G
    NEURORADIOLOGY, 1998, 40 (09) : 567 - 573
  • [25] Intracranial vascular stenosis and occlusion: comparison of 3D time-of-flight and 3D phase-contrast MR angiography
    M. Oelerich
    M. G. Lentschig
    P. Zunker
    P. Reimer
    E. J. Rummeny
    G. Schuierer
    Neuroradiology, 1998, 40 : 567 - 573
  • [26] Flow Analysis in Cardiac Chambers Combining Phase Contrast, 3D Tagged and Cine MRI
    Chabiniok, Radomir
    Wong, James
    Giese, Daniel
    Nordsletten, David
    Shi, Wenzhe
    Greil, Gerald
    Rueckert, Daniel
    Razavi, Reza
    Schaeffter, Tobias
    Smith, Nic
    FUNCTIONAL IMAGING AND MODELING OF THE HEART, 2013, 7945 : 360 - 369
  • [27] Laser centerline extraction method for 3D measurement of structured light in multi-scenarios
    Song X.
    Li J.
    Chen H.
    Li F.
    Wan C.
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2020, 49 (01):
  • [28] A robust and accurate centerline extraction method of multiple laser stripe for complex 3D measurement
    Yang, Tian
    Wu, Shiwei
    Zhang, Song
    Yang, Shichao
    Wu, Yanxue
    Liu, Fei
    ADVANCED ENGINEERING INFORMATICS, 2023, 58
  • [29] MR imaging of renal allografts with cine-phase contrast blood flow measurement
    Smith, JK
    Kenney, PJ
    Queen, EP
    RADIOLOGY, 1996, 201 : 1595 - 1595
  • [30] Visualization of intraaneurysmal flow patterns with transluminal flow images of 3D MR angiograms in conjunction with aneurysmal configurations
    Satoh, T
    Onoda, K
    Tsuchimoto, S
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2003, 24 (07) : 1436 - 1445