Selective and sensitive determination of phenolic compounds using carbon screen printing electrodes modified with reduced graphene oxide and silver nanoparticles

被引:8
|
作者
Chakkarapani, Lakshmi Devi [1 ]
Bytesnikova, Zuzana [2 ]
Richtera, Lukas [2 ]
Brandl, Martin [1 ]
机构
[1] Univ Continuing Educ, Ctr Water & Environm Sensors, Krems, Austria
[2] Mendel Univ Brno, Dept Chem & Biochem, Zemedelska 1, Brno 61300, Czech Republic
关键词
Nanoparticles; Screen -printed electrodes; Butylated hydroxyanisole; Reduced graphene oxide; Vanillin; BUTYLATED HYDROXYANISOLE BHA; VOLTAMMETRIC DETERMINATION; ELECTROCHEMICAL DETECTION; ANTIOXIDANT ACTIVITY; ASCORBIC-ACID; FOOD SAMPLES; VANILLIN; SENSOR; METAL; HYDROXYTOLUENE;
D O I
10.1016/j.apmt.2024.102113
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Butylated hydroxyanisole (BHA) and vanillin (VA) are the well-known phenolic compounds often used as preservatives in various foods and beverages. BHA is a safe additive whose concentration in food should not exceed 0.02 %. VA is used as a flavoring agent in foods, but the maximum allowable amount for VA is limited to 7 mg/ 100 g. However, elevated levels of BHA and VA can lead to severe health issues in the human body. To ensure reliable quality control, the food industry must accurately determine the BHA and VA content in food. In this work, we developed an electrochemical sensor for the detection of BHA and VA using a screen-printed electrode (SPE) modified with reduced graphene oxide and silver nanoparticles (RGO-Ag NPs). The SPE modified with RGO-Ag NPs showed an oxidation potential for BHA of 0.34 V and 0.62 V for VA in phosphate buffer solution (0.1 M PBS, pH 7.4) at a scan rate of 50 mV/s. In contrast, the unmodified SPE shows no significant current and oxidation potential response of BHA and VA under the same experimental conditions. (Cyclic voltammetry (CV) measurements for BHA ranged from 9.9 mu M to 239.25 mu M, while differential pulse voltammetry (DPV) measurements of BHA provided a linear calibration from 0.49 mu M to 3.67 mu M with a lower detection limit of 0.16 mu M (S/N = 3). For VA, CV measurements covered a range from 82.6 mu M to 242.4 mu M, and DPV measurements displayed a linear calibration from 1.47 mu M to 12.79 mu M with a detection limit of 0.15 mu M (S/N = 3).
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Electrochemically Reduced Graphene Oxide Modified Screen-Printed Electrodes for Sensitive Determination of Acetylsalicylic Acid
    Zhao, Chunzhi
    Ling, Jihong
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (11): : 10177 - 10186
  • [2] Highly sensitive determination of benorilate using silver nanoparticles/polyindole/reduced graphene oxide nanocomposite modified electrode
    Li, Rong-Fang
    Zhang, Sheng-Feng
    Kong, Fen-Ying
    Wang, Zhong-Xia
    Fang, Hai-Lin
    Wang, Wei
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2021, 903
  • [3] Electrochemical determination of NADH using screen printed carbon electrodes modified with reduced graphene oxide and poly(allylamine hydrochloride)
    Oana-Maria Istrate
    Lucian Rotariu
    Camelia Bala
    Microchimica Acta, 2016, 183 : 57 - 65
  • [4] Electrochemical determination of NADH using screen printed carbon electrodes modified with reduced graphene oxide and poly(allylamine hydrochloride)
    Istrate, Oana-Maria
    Rotariu, Lucian
    Bala, Camelia
    MICROCHIMICA ACTA, 2016, 183 (01) : 57 - 65
  • [5] Voltammetric detection of carbofuran determination using screen-printed carbon electrodes modified with gold nanoparticles and graphene oxide
    Jirasirichote, Apapond
    Punrat, Eakkasit
    Suea-Ngam, Akkapol
    Chailapakul, Orawon
    Chuanuwatanakul, Suchada
    TALANTA, 2017, 175 : 331 - 337
  • [6] Voltammetric Determination of Trace Methyl Parathion using Electrochemically Reduced Graphene Oxide Modified Carbon Screen-Printed Electrodes
    Azimi, Hesameddin
    Sullivan, Connor
    Lu, Dingnan
    Brack, Eric
    Drew, Christopher
    Kurup, Pradeep
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2023, 15 (05): : 356 - 370
  • [7] Naproxen electrooxidation using carbon paper electrodes modified with reduced graphene oxide and platinum nanoparticles
    Molina, J.
    Olcina, L.
    Bonastre, J.
    Cases, F.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2024, 967
  • [8] Highly sensitive determination of piroxicam using a glassy carbon electrode modified with silver nanoparticles dotted single walled carbon nanotubes-reduced graphene oxide nanocomposite
    Zhang, Jin-Wei
    Li, Rong-Fang
    Yao, Lei
    Wang, Zhong-Xia
    Lv, Wei-Xin
    Kong, Fen-Ying
    Wang, Wei
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 823 : 1 - 8
  • [9] Determination of sunset yellow and tartrazine in drinks using screen-printed carbon electrodes modified with reduced graphene oxide and NiBTC frameworks
    Wu, Jen-Han
    Lee, Hui-Ling
    MICROCHEMICAL JOURNAL, 2020, 158
  • [10] MODIFIED SCREEN-PRINTED CARBON ELECTRODES WITH TYROSINASE FOR DETERMINATION OF PHENOLIC COMPOUNDS IN SMOKED FOOD
    Dragancea, V.
    Sturza, R.
    Boujtita, M.
    CHEMISTRY JOURNAL OF MOLDOVA, 2010, 5 (02): : 47 - 53