Selective and sensitive determination of phenolic compounds using carbon screen printing electrodes modified with reduced graphene oxide and silver nanoparticles

被引:8
|
作者
Chakkarapani, Lakshmi Devi [1 ]
Bytesnikova, Zuzana [2 ]
Richtera, Lukas [2 ]
Brandl, Martin [1 ]
机构
[1] Univ Continuing Educ, Ctr Water & Environm Sensors, Krems, Austria
[2] Mendel Univ Brno, Dept Chem & Biochem, Zemedelska 1, Brno 61300, Czech Republic
关键词
Nanoparticles; Screen -printed electrodes; Butylated hydroxyanisole; Reduced graphene oxide; Vanillin; BUTYLATED HYDROXYANISOLE BHA; VOLTAMMETRIC DETERMINATION; ELECTROCHEMICAL DETECTION; ANTIOXIDANT ACTIVITY; ASCORBIC-ACID; FOOD SAMPLES; VANILLIN; SENSOR; METAL; HYDROXYTOLUENE;
D O I
10.1016/j.apmt.2024.102113
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Butylated hydroxyanisole (BHA) and vanillin (VA) are the well-known phenolic compounds often used as preservatives in various foods and beverages. BHA is a safe additive whose concentration in food should not exceed 0.02 %. VA is used as a flavoring agent in foods, but the maximum allowable amount for VA is limited to 7 mg/ 100 g. However, elevated levels of BHA and VA can lead to severe health issues in the human body. To ensure reliable quality control, the food industry must accurately determine the BHA and VA content in food. In this work, we developed an electrochemical sensor for the detection of BHA and VA using a screen-printed electrode (SPE) modified with reduced graphene oxide and silver nanoparticles (RGO-Ag NPs). The SPE modified with RGO-Ag NPs showed an oxidation potential for BHA of 0.34 V and 0.62 V for VA in phosphate buffer solution (0.1 M PBS, pH 7.4) at a scan rate of 50 mV/s. In contrast, the unmodified SPE shows no significant current and oxidation potential response of BHA and VA under the same experimental conditions. (Cyclic voltammetry (CV) measurements for BHA ranged from 9.9 mu M to 239.25 mu M, while differential pulse voltammetry (DPV) measurements of BHA provided a linear calibration from 0.49 mu M to 3.67 mu M with a lower detection limit of 0.16 mu M (S/N = 3). For VA, CV measurements covered a range from 82.6 mu M to 242.4 mu M, and DPV measurements displayed a linear calibration from 1.47 mu M to 12.79 mu M with a detection limit of 0.15 mu M (S/N = 3).
引用
收藏
页数:14
相关论文
共 50 条
  • [31] A selective and sensitive electrochemical determination of catechol based on reduced graphene oxide decorated β-cyclodextrin nanosheet modified glassy carbon electrode
    Nikhil, S.
    Karthika, A.
    Suresh, P.
    Suganthi, A.
    Rajarajan, M.
    ADVANCED POWDER TECHNOLOGY, 2021, 32 (07) : 2148 - 2159
  • [32] Sensitive Voltammetric Determination of Baicalein at Thermally Reduced Graphene Oxide Modified Glassy Carbon Electrode
    Zhang, Dongdong
    Zhang, Yanmin
    He, Langchong
    ELECTROANALYSIS, 2013, 25 (09) : 2136 - 2144
  • [33] Highly sensitive simultaneous electrochemical determination of hydroquinone, catechol and resorcinol based on carbon dot/reduced graphene oxide composite modified electrodes
    Zhang, Wuxiang
    Zheng, Jianzhong
    Lin, Zhongqiu
    Zhong, Ling
    Shi, Jiangu
    Wei, Chan
    Zhang, Hanqiang
    Hao, Aiyou
    Hu, Shirong
    ANALYTICAL METHODS, 2015, 7 (15) : 6089 - 6094
  • [34] Visual and spectrophotometric determination of mercury(II) using silver nanoparticles modified with graphene oxide
    An’amt Mohamed Noor
    Perumal Rameshkumar
    Nay Ming Huang
    Lee Seong Wei
    Microchimica Acta, 2016, 183 : 597 - 603
  • [35] Visual and spectrophotometric determination of mercury(II) using silver nanoparticles modified with graphene oxide
    Noor, An'amt Mohamed
    Rameshkumar, Perumal
    Huang, Nay Ming
    Wei, Lee Seong
    MICROCHIMICA ACTA, 2016, 183 (02) : 597 - 603
  • [36] A glassy carbon electrode modified with graphene oxide and silver nanoparticles for amperometric determination of hydrogen peroxide
    An’amt Mohamed Noor
    Muhammad Mehmood Shahid
    Perumal Rameshkumar
    Nay Ming Huang
    Microchimica Acta, 2016, 183 : 911 - 916
  • [37] A glassy carbon electrode modified with graphene oxide and silver nanoparticles for amperometric determination of hydrogen peroxide
    Noor, An'amt Mohamed
    Shahid, Muhammad Mehmood
    Rameshkumar, Perumal
    Huang, Nay Ming
    MICROCHIMICA ACTA, 2016, 183 (02) : 911 - 916
  • [38] Reduced Graphene Oxide Modified Electrodes for Sensitive Sensing of Gliadin in Food Samples
    Chekin, Fereshteh
    Singh, Santosh K.
    Vasilescu, Alina
    Dhavale, Vishal M.
    Kurungot, Sreekumar
    Boukherroub, Rabah
    Szunerits, Sabine
    ACS SENSORS, 2016, 1 (12): : 1462 - 1470
  • [39] Reduced Graphene Oxide Screen-Printed FTO as Highly Sensitive Electrodes for Simultaneous Determination of Dopamine and Uric Acid
    Ahammad, A. J. Saleh
    Islam, Tamanna
    Hasan, Md. Mahedi
    Mozumder, M. N. Islam
    Karim, Rejwana
    Odhikari, Noyon
    Pal, Poly Rani
    Sarker, Subrata
    Kim, Dong Min
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2018, 165 (05) : B174 - B183
  • [40] Simultaneous and selective electrochemical determination of dihydroxybenzene isomers at a reduced graphene oxide and copper nanoparticles composite modified glassy carbon electrode
    Palanisamy, Selvakumar
    Karuppiah, Chelladurai
    Chen, Shen-Ming
    Yang, Cheng-Yu
    Periakaruppan, Prakash
    ANALYTICAL METHODS, 2014, 6 (12) : 4271 - 4278